Computer cables are electrical equipment cables, suitable for electronic computers and automated instruments with high requirements for anti-interference at rated voltages of 500V or below. Depending on the specific environmental and usage requirements of the equipment, the cable insulation can be made from materials such as polyethylene, polyvinyl chloride, cross-linked polyethylene, fluoro plastics, and silicone rubber.
Each pair of twisted sheathes and between twisted sheathes and the overall sheath should be uninterrupted.
The cores of the cables should withstand a non-penetration under an alternating voltage of 2000V for 1 minute or 1500V for 5 minutes at 50Hz, as well as between cores and between cores and the shielding or other metallic layers.
High insulation resistance and excellent voltage resistance of polyethylene, along with a small dielectric constant and minimal temperature and frequency-dependent dielectric loss, not only meet transmission performance requirements but also ensure the cable's service life.
To minimize mutual interference between loops and external interference, the cables must be constructed with a shielding structure. The shielding materials include tin-plated or untinned copper wire, copper strip, copper-plastic composite tape, and aluminum-plastic composite tape, among others. The metallic strips are produced by wrapping, with an overlap rate typically not less than 15%. However, specific standards may have special provisions, such as TICW/06, which requires the overlap rate of the shielding metallic strip to be not less than 25%. The metallic wire is produced by braiding, with a braiding coverage rate not less than 80%, and for higher interference resistance requirements, the coverage rate may not be less than 90%.
The shielding requirements for cables are individually adopted for different scenarios: segmented shielding (only for twisted pairs, with each twisted pair having its own shielding), overall shielding (the cable has a single overall shielding layer after the cores are stranded), and segmented + overall shielding (combining both structures). To meet higher requirements of users and usage scenarios, the overall shielding structure can be implemented using a composite shielding method, which includes two layers of shielding, consisting of metallic tape wrapping + metal wire braiding.
Note: If the cable has a segmented shielding structure, the shielding layers should have good insulation properties, and polyester tape or other non-absorbent wrapping tape should be applied on the outer side of the segmented shielding.
Name Edit Voice
DJYPV
Polyethylene insulated twisted copper wire braid shielded with PVC sheath
Electrical Cable Sleeves Count
Install indoor, cable trench, pipeline, etc., with static shielding requirements
Occasion
DJYVP
Polyethylene insulated twisted copper wire braid, overall shielded with PVC sheath
Electrical Cable Sleeves Count
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Occasion
DJYPVP
Polyethylene insulated twisted copper wire, braid shielded and overall shielded
Chlorinated Polyvinyl Chloride (PVC) sheathed computer cable
Install indoor, cable trenches, pipelines, etc., requiring electrostatic shielding
Occasion
DJYP2V
PVC-jacketed shielded copper braided tinned polyethylene insulated wire
Electrical Cable
Install indoor, cable trench, pipeline, etc., with static shielding requirements
Occasion
DJYVP2
Polyethylene insulated twisted copper strip, overall shielded with PVC sheath
Electrical Cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Occasion
DJYP2VP2
Polyethylene insulated twisted copper strips, both individually shielded and overall shielded polyvinyl chloride
Enwrap computer cable
Install indoor, cable trench, pipeline, etc., with static shielding requirements
Occasion
DJYP3V
Polyethylene insulated, twisted aluminum-plastic composite tape, shielded with polyvinyl chloride
Computer Cable Jacket
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Event
DJYVP3
Polyethylene insulated twisted aluminum-plastic composite tape, overall shielded with polyvinyl chloride
Computer cable sleeve
Install indoor, cable trenches, pipelines, etc., with static shielding requirements
Occasion
DJYP3VP3
Polyethylene insulated twisted aluminum-plastic composite tape with both shielded and total shielded versions
PVC jacket computer cable
Install indoor, cable trench, pipeline, etc., with static shielding requirements
Occasion
DJYPVR
Polyethylene insulated twisted copper wire braid shielded with PVC sheath
Computer Cable Jacket Soft
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Occasion
DJYVPR
Polyethylene insulated twisted copper wire braided overall shield with PVC sheath
Computer cable sleeve
Install indoor, cable trench, pipeline, etc., with static shielding requirements
Occasion
DJYPVPR
PVC insulated twisted copper wire braid with individual and overall shielding
Polyvinyl Chloride (PVC) sheathed soft computer cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Occasion
DJYP2VR
Polyethylene insulated twisted copper tape, shielded with PVC sheath, soft
Computer Cable
Lay indoor, cable trench, pipeline, etc., with static shielding requirements
Occasion
DJYVP2R
Polyethylene insulated twisted copper tape, overall shielded with PVC sheath, soft
Computer Cable
Install indoor, cable trenches, pipelines, etc., with static shielding requirements
Occasion
DJYP2VP2R
Polyethylene insulated twisted copper tape, both with individual shielding and overall shielding polyvinyl chloride.
Thermally protected soft computer cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Occasion
DJYP3VR
Polyethylene insulated, twisted pair of aluminum-plastic composite tape, shielded with polyvinyl chloride
Protective Soft Computer Cable
Install indoor, cable trench, pipeline, etc., with static shielding requirements
Occasion
DJYVP3R
Polyethylene insulated, twisted pair aluminum-plastic composite tape, overall shielded polyvinyl chloride
Computer cable sleeve
Lay indoor, cable trenches, pipelines, etc., with static shielding requirements
Occasion
DJYP3VP3R
Polyethylene insulated twisted aluminum-plastic composite tape, with both individual shielding and overall shielding
PVC jacketed soft computer cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Occasion
DJYPV22
PVC jacketed, braided shielded copper twisted pair with polyethylene insulation
Steel-braided jacketed computer cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Large mechanical external force fixed sites and withstand
DJYVP22
Polyethylene insulated twisted copper wire braid overall shielded with PVC sheath
Steel-braided computer cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Large mechanical external force fixed sites and withstand
DJYPVP22
Polyethylene insulated twisted copper wire with both individual and overall shielding
Chlorinated Polyvinyl Chloride (PVC) sheathed steel wire armored computer cable
Install indoor, cable trench, pipeline, etc., with static shielding requirements
Large mechanical external force fixed sites and withstand
DJYP2V22
Polyethylene insulated twisted copper strip, shielded with PVC sheath and steel wire
Computer cable with armor
Lay indoor, cable trenches, pipelines, etc., requiring electrostatic shielding
Large mechanical external force fixation sites and withstand
DJYVP2-22
Polyethylene insulated, twisted copper strip, overall shielded with PVC jacket, steel
Computer cable with armor
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Large mechanical force fixed sites and withstand
DJYP2VP2-22
Polyethylene insulated twisted copper tape, both individually shielded and overall shielded polyvinyl chloride
Thermally protected steel tape armored computer cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Large mechanical force fixed site and withstand
DJYP3V22
Polyethylene insulated twisted aluminum-plastic composite tape with shielding polyvinyl chloride
Computer Cable with Steel Tape Armor
Lay indoor, cable trench, pipeline, etc., requiring electrostatic shielding
Large mechanical external force fixation sites and withstand
DJYVP3-22
Polyethylene insulated, twisted aluminum-plastic composite tape, overall shielded with polyvinyl chloride
Computer Cable with Steel Tape Armor Sheath
Lay indoor, cable trench, pipeline, etc., with static shielding requirements
Large mechanical external force fixation sites and withstand
DJYP3VP3-22
Polyethylene insulated twisted aluminum-plastic composite tape with both shielded and total shielded types
PVC sheathed steel tape armored computer cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Large machinery with external force fixation and bearing capacity