详情描述

1. Fiber Optic CableCross-sectional illustration

 






2. Label

2.1 Fiber Chromatography

Serial Number

1

2

3

4

5

6

Color

Blue

Orange

Green

Brown

Gray

Please provide the Chinese content you would like translated into American English.

 

2.2 Pipe sleeveChromatography

Serial Number

1

2

3

4

Color

Blue

Orange

Green

Brown

 

3. Fiber Optic Cable Structure Dimensions

Fiber optic core count

/

24

Structure

/

1+5

Fiber Type

/

G.652D

Central

Material

mm

Phosphated steel wire

Reinforcement part

Dimensions

1.35

Loose-tube assembly

Material


PBT

Diameter

mm

1.65±0.05

Wall thickness

0.25±0.05

Each tube's large core count


6

Waterproofing layer

Materials

/

Cable grease

Armored layer

Materials

mm

Coated Steel Strip

Inner sleeve

Material

mm

Medium Density Polyethylene (MDPE)

InsideProtective thickness

1.2±0.1

Outer sheath

Material

mm

PVC

Outer Shell Thickness

1.0±0.1

Color


Blue

Fiber Optic Cable Diameter

mm

9.5±0.5

 

 

4. Optical Performance 

Fiber Optic Technical Parameters(ITU-T Rec. G.652D)

Fiber Optic Characteristics

Unit

Numeric

1.Geometry

Features

1.1  Coating Diameter

um

125±1.0

1.2  Chip/Tolerance of concentricity deviation

um

0.6

1.3  Coating non-roundness

%

1.0

1.4  Outer Coating Diameter

um

242±7

1.5  Outer Coating/Coating concentricity deviation

um

12

2.Attenuation

Features

2.1  1310nm OTDRDecay

dB/km

0.36

2.2  1550nm OTDRAttenuation

dB/km

0.22

3.Model Field Diameter

3.1  1310nmModular Field Diameter

um

9.2±0.4

3.2  1550nmMold diameter

um

10.4±0.5

 

5. Physical Properties 

 

5.1 Optical Cable Bend Radius: 12.5 Optical Cable Diameter(Static)

25 Optical Cable Diameter(Dynamic)

5.2 Cable application temperature range

Operating Temperature

: -40oC to +60oC

Storage,Transportation Temperature

: -40oC to +70oC

Installation Temperature

: -20oC to +60oC

 

 

 

 

 

 

5.3Key mechanical and environmental performance tests

Serial Number

Project

Testing Method

Acceptance Requirements

1

Stretched

IEC 60794-1-2-E1

- Load: 600 N(LongDue date) 

1500 N(Short-term)

- Tested Length: 50 Rice

- Load Duration: ≥1Minute

Long-term tension load:

- Fiber optic cable shows no significant strain

- No significant additional attenuation

Short-term tension load:

- Fiber Optic Strain: £ 0.4%

- Additional Attenuation: £ 0.1dB

After testing is completed:

- No apparent residual additional attenuation

- No visible residual fiber strain

- No fiber breaks and visible sheath cracks

- Fiber optic residual strain: £ 0.08%

2

Flatten

IEC 60794-1-2-E3

- Load: 1000 N (Long-term)

3000 N (Short-term) 

- Load Duration: ≥1Minute

Long-term flattened load:

- No significant additional attenuation

Under short-term compression loading:

- Additional Attenuation: £ 0.1dB

After testing is completed:

- No significant residual additional attenuation

- No fiber breaks and visible sheath cracks

3

Impact

IEC 60794-1-E4

- Impact Points: 5dot

- Each point impact frequency:1Next

- Impact Energy:10 N·m

After testing is completed:

- No significant residual additional attenuation

- No fiber breaks and no visible crack in the sheath

4

Repetitive bending

IEC 60794-1-2-E6

- Core shaft radius: 25 Optical Cable Diameter

- Load: 25kg

- Tested Length: 1Rice

- Bend Rate: 2 Second/Next

- Bend cycles: 30Next

- Bend Angle: ±9 

After testing is completed:

- No significant residual additional attenuation

- No fiber breaks and visible sheath cracks

5

Twist

IEC 60794-1-E7

- Tested Length: 1 Rice

- Load: 25kg

- Twist Angle: ±9

- Twist cycles: 10Next

After testing is completed:

- No apparent residual additional attenuation

- No fiber breaks and no visible cracks in the sheath

6

Water Permeability Test

IEC 60794-1-F5B

- Water Column Height: 1Rice

- Sample Length: 3Rice

- Test Time: 24hour

- No leakage

 

6. Platter Packaging and Labeling 

 

6.1 Packaging

6.1.1 Optical Cable for ExportMulti-layer boardPlatter/Ironwood tray packaging

6.1.2 Standard Serving Length:2000m/3000m/4000m2% 0

 

6.2 Label

6.2.1 Dishware Label Content

Manufacturer's Name &LOGO;

Arrow indicating correct scrolling direction;

Arrow indicating the location of the cable's outer end;

Proper Handling and Placement of Fiber Optic Cables Sign;

Other customer required identification content 

6.2.2 Signage

Product Name;

Fiber Optic Cable Models and Specifications;

Plating Length;

Gross Weight,Net Weight;

Lot Number;

Manufacturer's Name;

Manufacturing Date and Month;

Other identification content required by customers

6.3 Cable Quality Assurance Documentation

Test Report