详情描述

Railway signal cables are suitable for transmitting railway signals, audio signals, or automatic signal devices with rated voltages of AC 500V or DC 1000V and below.

Control circuit, where the integrated sheath railway signal cable has certain shielding properties, suitable for electrified sections or other areas with strong electromagnetic interference.

Area installation for electrical interference.

1. Usage Features

1.1 The cable's operating temperature range is -40℃ to +60℃.

1.2 The long-term working temperature of the cable conductor should not exceed +70°C.

1.3 Cable Laying Environmental Temperature: The polyvinyl chloride (PVC) sheathed cable should not be below 0℃; the polyethylene (PE) sheathed cable should not be below -20℃.

1.4 Allowable Bend Radius for Cable: Non-armored cable should not be less than 10 times the outer diameter of the cable; armored cable should not be less than 15 times the outer diameter of the cable.

1.5 The ideal shielding coefficient for the overall sheathed railway signal cable is ≤0.8; for the aluminum sheathed railway signal cable, the ideal shielding coefficient is ≤0.3.

2 Model, Name and Specifications

Model Name Laying Range Specifications (Cores)

PTYV polyethylene insulated PVC sheathed railway signal cables laid in soil, trenches, or pipes can withstand general mechanical stresses. Recommended core counts are 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61C cores * 1.0mm

PTYY insulated polyethylene sheathed railway signal cables are recommended for cores of 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61C x 1.0mm.

PTY22 polyethylene insulated steel tape armored polyvinyl chloride sheathed railway signal cables are laid in soil, trenches, and pipes, capable of withstanding significant mechanical external forces. Recommended for cores of 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61C cores * 1.0mm.

PTY23 Polyethylene Insulated Steel Tape Armored Polyethylene Sheathed Railway Signal Cable - Recommended Core Numbers: 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61C cores * 1.0mm

PTYA22 Polyethylene Insulated Composite Sheath Steel Tape Armored PVC Outer Sheath Rail Signal Cable - Recommended Core Numbers: 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61C cores * 1.0mm

PTYA23 Polyethylene Insulated Composite Sheath Steel Tape Armored Polyethylene Outer Sheath Railway Signal Cable, recommended conductor counts: 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61 cores * 1.0mm

PTYL23, Aluminum sheathed railway signal cable. Recommended core counts: 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61 cores * 1.0mm

PTYA polyethylene insulated comprehensive sheath polyethylene outer sheath railway signal cables, recommended cores: 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61C * 1.0mm

Plastic insulated and polyvinyl chloride sheathed railway signal cablesPTYAHPTYAPZYAPTYVPTYYPTY22PTY23 (PZY02PZY03PZY23PZY22) with 1/0.8mm (1/1.0mm) conductors, 2-48 cores, suitable for railway signal communication, fire alarm signals, telegrams, and other automatic system applications at rated voltages of AC 500V or DC 1000V and below.

Polyethylene Insulated Composite Sheath Steel Tape Armored PVC Sheathed Railway Signal Cable

PTYA23, PTYA22, PTY23, PTY22, PTYAH23, PZYA23, PZYA22, PZY23, PZY22 - 20.8mm (1/1.0MM) 4-61 cores suitable for transmission of audio signals and fixed-installed railway signaling and group automation control lines at alternating voltage ratings of 500V or direct voltage ratings of 1000V and below. It can transmit general automatic signals for railway groups and also transfer frequency-changing automatic block signals and business communication audio signals.

  

Our company specializes in the production of mining communication cables, control cables, signal cables, coal mine communication cables, explosion-proof telephonic cables, explosion-proof communication cables, coal mine control cables, coal mine signal cables, mining communication cables, mining telephonic cables, mining telephonic lines, flame-retardant mining communication cables, flame-retardant signal cables, flame-retardant control cables, mine communication cables, mine signal cables, mine control cables, mining monitoring cables, mining surveillance cables, mine telemetry cables, mining monitoring lines, mining telephonic cables, explosion-proof mining cables, mining cables, flame-retardant mining cables; sensor cables; MHYV, MHYAV, MHYA32 mining communication cables; MHYV, MHYVR, MHYVP, MHYVRP, MHY32 mining signal cables (mining communication cables); MKVV, MKVV22, MKVV32, MKVVR mining control cable products all have the "Coal Safety Mark" certificate, with complete specifications, widely used in major coal mine systems and monitoring systems; sold to coal companies and mining groups across the country; and has become the matching product of many mining equipment companies, establishing long-term cooperative relationships, and the products have always received positive feedback and trust from customers!

We also produce full-plastic indoor communication cables, telephone cables, large-pair communication cables, computer cables, and power cables for communication equipment; railway signal cables. We have all the necessary authoritative certificates, ensuring reliable quality!!