MRI Shielding Room | MRI Protection | MRI Shielding Company_News Center Co., Ltd._Shandong Pengbo Radiation Shielding Materials Co., Ltd._Zhongshang 114 Industry Resources Network 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Shandong Pengbo Radiation Shielding Materials Co., Ltd.
Shandong Pengbo Radiation Shielding Materials Co., Ltd.

Manufacturing various lead products: lead sheets, lead po...

24-hour Service Hotline
17506351118
0635-5551255
Current Location:Home>News Center Co., Ltd.>MRI Shielding Room | MRI Protection | MRI Shielding Company

    MRI Shielding Room | MRI Protection | MRI Shielding Company

    2024-11-26

    Magnetic Resonance Imaging (MRI) Shielding Room|Magnetic Resonance Imaging (MRI) Protection|MRI Shielding|MRI Shielding Company

    MRIShielded RoomNMR-Specific Magnetic Shielding and RF Copper Plate Shielding, designed to protect nuclear magnetic resonance equipment from external electromagnetic field interference. Pengbo Radiation Shielding, catering to customer needs, can design dual-functional nuclear magnetic resonance shielding with both magnetic field and RF shielding capabilities.Isolation Room

    Section II: Shielding Effectiveness:In accordance with the GB12190-90 national standard testing:

    (1) Shielding Effectiveness: 10MHz ~ 100MHz ≥100dB
    (2) Ground Insulation: >3KΩ-10KΩ

    III. Production Basis:

    Magnetic Resonance ShieldingNo Chinese content provided.The structure should minimize the use of ferromagnetic materials, as most ferromagnetic materials can affect the uniformity of the magnetic field, impacting image quality. Good shielding plays a significant role in improving image quality. Indoor lighting should be LED-based, and observation windows should be lined with copper mesh shielding material. The double-glazed windows must be securely sealed, and insulated from surrounding buildings. Grounding should be achieved through a single point, with the grounding resistance being less than the specified value. Power lines and signal cables entering the room must be routed through the entrance.FilterFiltering processed.

    The Impact of Magnetic Fields on the External Environment:


    Small Distance Impact (Meters)Affected Equipment
    5Computers, magnetic tapes, disks
    6Pacemaker
    7Viewing tubes or other cathode-ray tube instruments
    15X-ray machines and gamma cameras with image enhancers, electron microscopes


    External Environmental Influence on Magnetic Fields:


    Occurred at a short distance (meters)Disturbance Source
    1Magnetic reinforcement on ceilings and floors, oxygen cylinders
    5Reinforcing steel in reinforced concrete
    12In-House Stroller, High-Power RF Generator
    15Elevators, automobiles, high-voltage cables, transformers


    Material Composition:

    1、Shield RoomThe housing is assembled on-site by welding modules made of 0.2-1mm copper or brass plates, while the skeletal frame is constructed from fire-resistant wood or aluminum alloy material.

    2. NMRPrivacy ShieldStandard door opening sizes: 0.9m x 2m, 1.2m x 2m, etc.; special sizes available upon customization.

    3. The honeycomb non-magnetic ventilation waveguide windows are available in sizes of 300mm x 300mm and 300mm x 600mm.

    4、Isolation RoomThe power and signal lines of the equipment are low-frequencyPower FilterConducting screening procedures.

    5. Indoor lighting features anti-magnetic ceiling incandescent or LED bulbs, while outdoor setups include power control cabinets.

    6. In accordance with the standard requirements,Shield RoomAppropriate shielding observation windows, signal transmission boards, air conditioning shielding treatment, medical gas waveguide interfaces, etc., should be configured.


    Five. Trusted Experience and Capabilities (Design, Production, Construction, Management)
    Shandong Pengbo Radiation Shielding Materials in NMRIsolation RoomDesign, production, and construction—our company leads the pack among peers. Guided by the principle of upholding customer interests and meeting their demands, we ensure the high quality of our work while guaranteeing short project timelines. We complete shielding projects on time, meet all the criteria of international quality system certifications, and deliver satisfaction and peace of mind to our users.

    Six: Technological and quality edge over peers.
    Boasting independent R&D capabilities and cutting-edge technology that keeps pace with the world, we continuously innovate and provide robust technical support. This ensures our products remain at the forefront, earning recognition and collaboration from equipment companies worldwide and a broad user base.




Contact us

Shandong Pengbo Radiation Shielding Materials Co., Ltd.
Service Hotline 17506351118
Company Phone 0635-5551255
Company Address No Chinese content provided.

Message Consultation

 Click OK to indicate that you agree to《Service terms》《Privacy policy》

b2b.china9.net © Zhongshang 114 Hebei Network Technology Co., Ltd.Address: Room 6009, Oriental New World Center, No.118 East Zhongshan Road, Qiaoxi District, Shijiazhuang City, Hebei ProvincePlatform Service Hotline: 4006299930

 Click OK to indicate that you agree to《Service terms》《Privacy policy》