Henan Hengji Building Quality Inspection & Testing Co., Ltd., offering services including building inspections, school building inspections, kindergarten building inspections, community building inspections, etc. The company is fully equipped with qualifications and facilities to conduct various building quality inspections and issue valid certificates. We have obtained the CMA inspection and testing system certification!
Why Do You Need an Earthquake Resistance Assessment?
1) To implement a policy of prioritizing prevention in work, to mitigate damage and property loss, and to assess the seismic capacity of existing buildings, providing a basis for seismic reinforcement or the adoption of other seismic disaster mitigation measures.
2) Structures not equipped with seismic resistance or reinforcement.
3) Alterations, expansions, and additions that change the building structure, affecting overall seismic performance.
4) During use, after destructive events, floods, storms, fires, etc., there may be local collapses, cracks, or severe damage to the load-bearing structure's seismic resistance.





Henan Hengji Housing Quality Inspection & Testing Co., Ltd., services include: housing inspections, school housing inspections, kindergarten housing inspections, community housing inspections, etc. The company is fully equipped with qualifications and equipment, capable of conducting inspections and testing on various housing quality, and issuing valid certificates. We have obtained the CMA Inspection and Testing System Certification!
With the rapid development of industry, many cities have established factories. However, as factories operate continuously, they are prone to quality issues due to machine vibrations or other factors. Therefore, we need to conduct regular inspections on the factories. Sometimes, when a factory experiences problems, reinforcement and renovation work is required. Before construction begins, a detection and assessment report must be prepared. These reports cover several aspects. Today, I will provide a detailed explanation of the inspections before factory reinforcement and renovation.
In fact, factory safety and seismic inspections are required both before and after the reinforcement construction. Prior to the renovation, a re-evaluation and modeling calculation of the factory's structure and load-bearing capacity is necessary to provide data support and recommendations for the renovation project and plans. After the renovation, a review and acceptance of the factory's renovation status and drawings are needed, with Nanyang School Safety Inspection Company involved, to ensure the quality of the renovated factory and meet its requirements. This is what we refer to as the completion acceptance.
Henan Hengji Housing Quality Inspection & Testing Co., Ltd., services include: housing inspections, school housing inspections, kindergarten housing inspections, community housing inspections, etc. The company is fully equipped with qualifications and equipment, capable of conducting inspections and testing on various housing quality, and issuing valid certificates. It has obtained the CMA Inspection and Testing System Certification!

Billboard Appearance Inspection
On-site inspection revealed peeling paint and rust on the billboard steel columns, with some missing nuts and loose nuts on the anchor bolts. The truss members of the billboard also showed severe paint peeling and rust, while the rest of the components were in good condition with no obvious damage found.
1. Axle grid dimensions and component geometric dimensions verification
On-site, the billboard's axis network dimensions and component geometries are sampled and reviewed using steel measuring tapes and vernier calipers. The test results indicate that the deviations of the billboard's axis network dimensions are within the permissible range as specified by the standard, meeting the design requirements.
The table shows that, except for the steel column wall thickness deviation exceeding the specifications, the geometric dimensions of the rest of the billboard components basically meet the design requirements.
Billboard Tilt Detection
Using a total station, measurements were taken according to the relevant regulations for the point placement method in deformation measurement. The results indicate that the billboard steel column has shifted northward by 18mm with a tilt rate of 0.86‰, and eastward by 26mm with a tilt rate of 1.24‰. Although the steel column is slightly tilted, it does not exceed the allowable limit of 4‰ as specified by the standards, meeting the usage requirements.
Henan Hengji Building Quality Inspection Co., Ltd. specializes in "building safety inspections, seismic performance testing and certification, and school building inspections." The company adheres to the philosophy of "honest business practices and dedicated service" to provide you with better products and services. Welcome to call for inquiries! Contact: Manager Sun.