- AllProduct Category
-
Powder Property Tester
Powder Flowability Tester
Bulk Density Gauge
Loose Density Tester
Pile Density Tester
Apparent Density Meter
Rest Angle Gauge
Rest Angle Gauge
Particle Strength Tester
Powder Resistivity Tester
Compaction Density Gauge
Hole Flowmeter
Four-Probe Resistance/Resistivity Tester
Surface and Volume Resistivity Tester for Insulating Materials
Conductor Material Resistivity Tester
High Temperature Resistivity Tester
Voltage Drop Tester


详情描述
FT-552Composite Collector FluidHigh-voltage resistance tester
Application InstructionsApplication Description
Composite collector fluid is used“Sandwich”Structure: middle layer of high polymer organic substances, top and bottom layers of copper/Aluminum metal, with“High polymer matrix+Thinner Conductive Layer (Copper)/Aluminum”Structure: intermediate layer is non-conductive; composite aluminum foil is prepared by vacuum deposition; composite copper foil is prepared by a multi-step process; using magnetic sputtering、Vacuum Deposition、Electroplating and other technologies coat a copper layer onto the base material surface.; TraditionalCollector assemblyComparison Points:In the event of an internal short circuit in the battery, the short circuit current can be cut off by blowing a fuse, effectively preventing thermal runaway of the battery.;The advantages of composite fluid concentrates are demonstrated in higher safety, energy density, and lower manufacturing costs.;Excellent flame retardancy, effectively controlling the spread of fire.
Principle DescriptionPrinciple explanation
FT-552Composite collector fluidHigh Resistance Film Meter
Adopting the "synchronous hierarchical method" forComposite Collector PlateAll resistance levels, resistivity, overall conductive layer resistance, and compaction density are measured..
Function Introduction
Automated testing of various fluid layersResistors, resistivity, compaction density.
Automatic Pressure;Pressure is adjustable. PC Software Interface Operation
Multiple measurement modesAchieve pressure and resistance, resistivity, and conductivity relationship charts
Automatic positive/negative current output, automatic positive/negative voltage measurement
Provide data and report generation management.Automatic Sample Thickness Measurement
Technical Specifications
FT-552Composite Collector StreamHigh Resistance Film Meter
Specification Model | FT-552 |
Resistor | 10^-8~2×10^4Ω |
2. Resistivity | 10^-8~2×10^4Ω-cm |
4. Test Current | 0-10A, 100uA |
5. Resistance Accuracy | Standard resistor ≤0.3%Resolution 0.01μΩ |
6. PC Software Operation | PC Software Interface: Resistance Value, Resistivity, Conductivity Value, Temperature, Pressure Value, Unit automatic conversion, cross-section, height, charts, compacted density, generating reports, etc. |
7. Pressure RangeSelect | 500kg; 1000kg as requiredSelection Requirements. |
8. Test Electrode | Copper material, other specifications available for customization |
9. Test Itinerary | 0-20mm, displacement accuracy 0.01mm |
10. Sample Thickness | 0-10mm; Precision: 0.001mm |
11. Pressure Method | Automatic |
12. Protective Functions | Limited range and pressure protection;误operation and emergency stop protection; abnormal alarm |
13. Maintenance and Care | Standard operation prompt with identification; maintenance and care reminders |
14. Power Supply | AC 220V±10%. 50Hz, Power Consumption: <100W |