详情描述

FT-300 Series Hydraulic Conductor Powder Resistivity Tester

Overview:

The four-end measurement method is applicable to lithium battery materials, graphene, graphite, carbon powder, coking, petrochemicals, powder metallurgy, colleges and universities, and scientific research departments. It is a tool for inspecting and analyzing the quality of conductive powder samples.4.3Inch LCD screen display, simultaneously showing resistance value, resistivity, conductivity value, temperature, pressure value, with automatic unit conversion, standard configurationFT-01AManual powder measuring device.Film switch panel, available in both Chinese and English operating interfaces

II. Reference Standards:

YST 587.6-2006 Carbon Anode Petroleum Coke After Calcination Test Method No.6Partial measurement of powder resistivity; Standard manual powder testing device,When testing the powder, data such as the height, diameter, and pressure after compaction can be obtained through the device, and the required data can be automatically calculated..Conveniently address the measurement needs for resistivity, resistivity rate, and conductivity of powdered and granular materials..

 FT-300 Series Conductor Powder Resistivity Tester (Hydraulic Type)

Section 3: Reference Standards:

1GB∕T24521-2018Method for measuring the resistivity of carbonaceous raw materials and coke;Pressure requirements3.9MPa±0.03MPaPowder mold inner diameter16mm-16.3mmHeight Measurement Range:15-17mmTest Current500mAThese parameters dictate the selection of instruments.b.Height Measurement Range:0.001-25.000mmPressure Rangea.200kgb.Mold Inner Diameter16-16.3 mmMold stroke height25mm.



 FT-300 Series Hydraulic Conductive Powder Resistivity Tester

2.YS/T 587.6-2006 Testing Method for Calcined Petroleum Coke Used in Carbon Anodes6Measurement of Partial Powder Resistivity;

 ISO 10143-1995 Determination of resistivity of calcined carbon granules for electrode use in aluminum production 

Requirements:c.Mold Internal Diameter30mmPressure requirement3 MPa±0.03MPa300kgRange);c.Mold Internal Diameter30mm

 

3Particle characteristics factors outside,During the powder resistivity test process,Pressure and mold cavity volume determine the effect of compaction density on powder conductivity..In addition to the standard requirements,; Recommend selecting small-sized mold cavities.

 

IV. Technical Specifications

Specification ModelFT-300I

Resistor10-7~2×107Ω

2. Resistivity10-7~2×107Ω-cm

3. Conductivity5×10-7~107s/cm

4. Test Current1μA,10μA,100µA,1mA,10mA,1000mA

5. Measure VoltageVoltage Measurement Ranges: 2mV, 20mV, 200mV, 2V

Measurement Accuracy ± (0.1% of Reading)

Resolution: 0.1uV, 1uV, 10uV, 100uV

6. Current Accuracy±0.1%±0.2% ±0.2% ±0.3% 

7. Resistance AccuracyStandard Resistance ≤0.3%Standard Resistor ≤0.3%Standard Resistance ≤0.3%Standard Resistor ≤0.5%

8. Display ReadingLCD Display: Resistance, Resistivity, Conductivity Values, Temperature, Pressure Values, Automatic Unit Conversion, Cross Section, Height, Upper and Lower Limit Alarms

9. Testing MethodFour-point measurement method

10. High RangeHeight Measurement Range: 0.01-10.01mm, Measurement Resolution: 0.01mm

11. Pressure RangeSelect a. 200kg; b. 300kg; c. 500kg; d. 1000kg

12. Measurement Device

Standard configuration: a. 10mm mold inner diameter for models with 200kg and 300kg pressure; b. 20mm mold inner diameter for models with 500kg and 1000kg pressure; mold stroke height of 25mm.

Pressure Method: Manual Hydraulic Pressure Measurement

13. Operating Power SupplyAC 220V±10%, 50Hz, Power Consumption: <30W

14. DimensionsMainframeRame: approx. L330mm * D350mm * H120mm; manual device aBout: Approximately H450mm x L200mm x D120mm

15. Net WeightApprox. 35 kg