详情描述
FT-361SJB Bipolar Plate Material Four-Probe Low Resistance/Contact Resistance Tester, Carbon Paper Resistance Meter
One.Overview:
Measurement and analysis of the sheet resistance of bipolar plate material and the contact resistance between the bipolar plate and carbon paper.
4.3Inch LCD screen display: Resistance, resistivity, sheet resistance, temperature, unit conversion, temperature coefficient, current, voltage, probe shape, probe spacing, thickness, conductivity, resistivity, pressure, automatic measurement, integrated circuit system, constant current output, as for selectionPCSoftware capable of analyzing the change curve graph of contact resistance under various pressures. Computer-controlled, with data saved and printed, and automatic report generation. Offer a choice of operating interface in either Chinese or English..

FT-361SJB Bipolar Plate Material Four-Probe Low Resistance/Contact Resistance Tester, Carbon Paper Resistance Meter
Two.Reference Standard:
GB/T 20042.6-2011Proton Exchange Membrane Fuel Cell6Partial: Test methods and requirements for four-probe low-resistance measurement and contact resistance testing in bipolar plate characteristic testing.
Three.Parameters and specifications
1.Square resistance range:1×10^-6~2×10^2Ω/□
2.Resistance range:10^-7~2×10^3Ω-cm
3.Test Current Range:1A、100mA、10mA、1mA、100uA、10uA、1uA、0.1uA
4.Current Accuracy:±0.1%Reading
5.Resistance Accuracy:≤0.3%
6.Display Readout: LCD Display: Resistance, Resistivity, Sheet Resistance, Temperature, Unit Conversion, Temperature Coefficient, Current, Voltage, Probe Shape, Probe Spacing, Thickness, Conductivity, Resistivity, Pressure, etc..
7.Testing Method: Four-probe measurement (bulk resistivity) and four-point method (contact resistance measurement)
8.Pressure Range:0-1000kg(0-4MPa).
9. Sample shape is square (gold-plated electrodes)5cm×5cm), area of25cm2(Other specifications available for customization)
10.Power Supply: Input: AC 220V±10% ,50Hz Power Consumption:<30W
11.Standard Configuration: Test Probe1Piece; Test Platform1Each; Master Unit1Set; Pressure Device1Set;
12.Standard Configuration; Standard Calibration Resistor1Piece

FT-361SJB Bipolar Plate Material Four-Probe Low Resistance/Contact Resistance Tester, Carbon Paper Resistance Meter