FT-400AHXM Chemical Conversion Coating Surface Resistance Tester Surface Resistance Meter


I. Product Features Introduction:

The four-point measurement method is applicable to manufacturing enterprises, colleges and universities, and research departments. Laboratory testing and analysis are used for chemical conversion materials applied to coated aluminum and aluminum alloys; as well as for the chemical conductive oxidation film layers of aluminum and aluminum alloys, which have specific requirements for surface contact resistance and resistivity measurement..

PCSoftware-operated interface, auto-run, automatically measure sample thickness to the thousandth place, real-time analysis of the resistance and pressure change curve diagram during the pressure application process, capable of displaying resistance, resistivity, and conductivity change diagrams, auto-generate reports.

Two.Reference Standard:

FT-400AHXM Chemical Conversion Film Surface Resistance Tester Surface Resistance Meter

1.MIL-DTL-81706B 25 October 2004Chemical conversion materials for coating aluminum and aluminum alloys

2.NAVY QPL-81706-16(2)-2002  Chemical conversion materials for aluminum and aluminum alloys coating

3.AMS2474BAluminum alloy chemical treatment low-resistance coating,1982.01.01Revised)Standard specification168Hour Neutral Salt Spray Test,Contact Resistance Between Front and Rear Chemical Conversion CoatingsMeasurement.

4.QJ 487-1983Aluminum and Aluminum Alloys Chemical Conductive Oxide Coating Standard 

Section 3: Technical Specifications

FT-400AHXM Chemical Conversion Film Surface Resistance Tester  Surface Resistance Meter

1.Resistivity:10^-72×10^7Ω-cm
2.Electricity Obstacle:10^-72×10^7Ω

3.Conductivity:5×10^-710^7s/cm

4.Resolution:0.1μΩ       Measurement Error 0.1%

5.Voltage Measurement Range: 2mV   20mV  200mV 2V 

6.Resolution:0.1uV  1uV  10uV  100uV

7.Current Output: DC Current 01000mA Continuous adjustable, powered by AC power supply.
Range:1μA10μA100µA1mA10mA1000mA, Error:±0.2%Reading±2Character

8. PCSoftware Interface: Resistance value, resistivity, conductivity value, temperature, pressure value, automatic unit conversion, cross-section, height, curve graphs, reports, etc..

9. Upper and lower electrode material: Gold-plated copper, electrodes must be1000Grit sandpaper for polishing to achieve smoothness

10. Pressure Load200psiAccuracy2psiInwards.

11. Up electrode cross-sectional area1Square Inches; cross-sectional area of lower electrode greater than1square inch

12.Pressure Method: Automatic

13. High Range and Precision: Height Measurement Range:0.001-10.001mmMeasurement Resolution0.001mm

14.Temperature and Humidity Range: Room Temperature-50Degrees; Humidity:20%-98%

15.Constant Pressure Time:0-99.9S

16.Standard components:a.Standard Calibration Resistor1Piece(s)b.Standard Height Calibration Piece1Individual

17.Testing Method: Four-Point Measurement Technique+Automatic Measurement

18. Operating Power Supply:220±10% 50HZ/60HZ