    Safety Precautions for the Use of Copper Wire in Digital Electronic Detonators

    2025-09-18

    1、Digital Tube Copper Core WireUse copper or iron-core insulated wires; the use of aluminum-core wires and bare wires is strictly prohibited.

    2、Blasting Copper Core WireJunctions between connecting wires, between connecting wires and detonator lead wires, and between lead wires themselves must be tightly twisted and suspended; they must not come into contact with conductive materials such as tracks, metal meshes, steel cables, scraper conveyors, etc.

    3. Tunneling progress underway.Digital Electronic Detonator Copper WireUse as needed and hang up. Fixed busbars are not allowed. In special cases, this restriction may not apply after safety measures are taken.

    4、Firecracker WireCables, wires, and signal lines should be hung on either side of the alley. If they must be hung on the same side, the busbar must be placed below the cables and maintainedSuspension distance of over 0.3 meters.

    5. Only single-loop blasting with insulated busbars is permitted; strictly prohibited is the use of tracks, metallic pipes, water, or the earth as a return path.

    6. Prior to the fireworks.Explosive WireMust be twisted into a short circuit.

    7、Mining blasting wireThe length must exceed the specified safe distance for fireworks.

    8、Mining blasting wireAvoid excessive connections to prevent increased resistance, wire breaks, or short circuits. Each connection should be rust-free and securely fastened, then wrapped with insulating tape.

    9、Firecracker WireWhen insulation is damaged, it must be wrapped promptly to prevent electrical leakage, short-circuit, or contact discharge, and to avoid accidental incidents.

    10、Firecracker Copper Core WireDo not use two conductors of different materials or specifications as busbars. It is strictly prohibited to use four-core multi-core or multiple-core conductors as busbars.

    11、Firecracker WireAfter use, the equipment should be dried before being lifted back to the surface; underground, it should be stored in a dry and safe location, and regular resistance measurements and insulation performance checks should be conducted on the busbars.




Contact us

Fujian Minbao Machinery Group Co., Ltd.
Service Hotline 13979959972
Company Phone 13979959972
Company Address No. 6 Jianglong Road, Xingang District, Longyan City, Fujian Province

Message Consultation

 Click OK to indicate that you agree to《Service terms》《Privacy policy》

b2b.china9.net © Zhongshang 114 Hebei Network Technology Co., Ltd.Address: Room 6009, Oriental New World Center, No.118 East Zhongshan Road, Qiaoxi District, Shijiazhuang City, Hebei ProvincePlatform Service Hotline: 4006299930