- AllProduct Category
-
Pressure Transmitter
Linear Position Sensor
Tie-rod Position Sensor
Magnetic-Inductive Level Gauge
Magnetic-Induced Eddy Current Displacement Sensor


详情描述
Robust and durable industrial sensor
Direct linear displacement measurement, value output
Offer various output modes: current, voltage, SSI, CANbus, and Profibus bus, etc.
■ Contactless measurement, no wear and tear
Resolution up to 1um
■ Non-linearity 0.01%
■ Repeated Precision: 0.001%
■ Meets IP67 sealing grade, fully sealed stainless steel housing
Technical Specifications:
| Parameters | Specs |
| Input | |
| Measurement Data | Linear Displacement |
| Measurement Stroke | Sensor type dependent; customizable according to customer requirements. |
| Count measurement | One |
| Output | |
| Output | Current, voltage, SSI, CANbus, and Profibus bus |
| Accuracy | |
| Resolution | Simulation: Infinite |
| Non-linearity | Full Scale Tolerance: 0.01% (Tiny Dust 40 μm) |
| Repeatability accuracy | Full scale dust 0.001% (Fine dust 2.5 um) |
| Lag | <4um typically 2um |
| Work Conditions | |
| Operating Temperature | -40~75℃ |
| Humidity/Dew Point | Humidity 90%, no condensation |
| Temperature Coefficient | <30ppm/℃ |
| Impact Index | 15g/ 100-2000 Hz / IEC Standard EN68-2-6 |
| Oscillator Indicator | Radiation IEC/EN 50081-1, immunity IEC/EN 50082-2, |
| Electrical Protection | IP67 |
| EMC Testing | Radiation IEC/EN 50081-1, immunity IEC/EN 50082-2, IEC/EN 61000-4-2/3/4/6, Grade 3/4, Class A, CE Certified |
| Structure and Materials | |
| Shell | Stainless Steel 303/304 |
| Measuring Rod | Stainless Steel 304, 8/10mm |
| Magnetic Ring | Various magnetic rings |
| Sealed | O-ring 40.87*3.53 mm NBR 80, Auxiliary washer 42.6*48*1.4 PTFE |
| Pressure-resistant | Installed inside the hydraulic cylinder, it operates at 350bar/700bar (peak). |
| Installation | |
| Installation Direction | Any direction |
| Installation Type | Metric threaded flange M18x1.5 or NPT 3/4"-16 UNF-3A |
| General locking force | 45 N-m |
| Electrical Connections | |
| Wiring method | Direct shipment cable (oil-resistant, heavy-duty), cable tail loose wire connection |
| Input Voltage | +24 Vdc (-15/+20%) |
| Polarity Protection | 30Vdc |
| Overpressure Protection | 36Vdc |
| Power consumption | Typically 100mA |
| Insulation strength | 500V (DC grounded to machine ground) |
The BH series sensors feature a protective shell, offering durability and can provide continuous, reliable, and real-time displacement signals in harsh environments. The sensors are sealed with a fully stainless steel shell, fully meeting the protection level IP68. Note: The electronic compartment is not removable.
Due to the use of non-contact measurement technology, the sensor can be integrated into a sealed housing isolated from the outside environment. The position magnet moves along the measuring rod, allowing for position measurement without mechanical contact. For level measurement, an optional float can be used. Sensors with protective-grade housing are easy to install and use, better meeting application requirements. Measurement accuracy and all technical parameters depend on the output characteristics of the selected sensor, with interface options available: analog or SSI.
Installation Structure and Wiring
The BH Waterproof Simulated Output Displacement Sensor is designed for built-in installation in hydraulic cylinders, featuring a compact integrated structure and ease of use.
Pressure-resistant outer tube dimensions and installation instructions
BH Waterproof and Pressure-resistant Outer Tube, Stainless Steel Electronic Housing, designed specifically for hydraulic systems use, integrated internally within the hydraulic cylinder, capable of withstanding pressure up to 34MPa continuous (69MPa peak). Thread specifications: M18×1.5, M20×1.5, or 3/4”-16 UNF-3A.
Sensor wiring method