详情描述


Robust and Reliable Industrial Position Sensors


Direct measurement, value output


LED indicator light diagnostic function


Contactless measurement, no wear


■ Ultra-high precision, with a resolution as high as 5 pm


■ Non-linearity up to 0.01%


■ Repeatability up to 0.001%


Profibus-DP Output

ParametersSpecs
Input
Measurement DataLocation, Speed (Value)
Measurement RangeRP Aluminum Molding Shell: 50 - 5080 mm; RH Pressure-resistant Outer Tube: 50 - 7620 mm
Output
InterfaceProfibus-DP system, ISO 74498
Data FormatProfibus-DP (EN- 50 170)
Transmission speed12 Mbit/s
Overvoltage Protection36Vdc
Accuracy
Resolution5 um / Users can freely modify the GSD files
Non-linearityFull range soil 0.01% (Fine soil 50 pm)
Repeatability PrecisionFull scale ± 0.001% (± 2.5 pm)
Temperature coefficient< 15 ppm / °C
Lag< 4 µm
Work Conditions
Operating Temperature- 40 to +75 °C
Humidity / Dew PointHumidity 90%, no condensation allowed
ProtectRP Aluminum Molding Shell: IP65 RH Pressure-resistant Outer Tube: IP67 (Connectors must be securely locked) or IP68 (Optional straight-out cable)
Impact Index100 g (single impulse) / IEC Standard 68-2-27
Oscillator Indicator15 g / 100 - 2000 Hz / IEC Standard 68-2-6 (Durability)
EMC TestingRadiation EN 50081-1, Immunity EN 50082-2, EN 61000-4-2/3/4/6, Class 3/4, Type A, CE Certified
Magnet SpeedAny
Structure, Materials
Fault IndicatorElectronic end caps with LED display
RP Aluminum Molding ShellSensor Head: Aluminum, Sensor Rod: Aluminum, Position Magnet: Slider Magnet or Floating Magnet
RH Pressure-resistant External PipeSensor Head: Aluminum    Sensor Rod and Flange: 304L Stainless Steel    Outer Tube Pressure: 350 bar / 690 bar (Peak)    Position Magnet: Ring magnet, floating magnet, or float ball
Install
Installation LocationAny direction
RP Aluminum Molding ShellDetachable mounting clip (to be secured with M5 screws)
RH Pressure-resistant Outer TubeMetric: M18 x 1.5 or NPT: 3/4"- 6 UNF-3A
General locking force45 N-m
Electrical Connections
Connector selection6 Pin D60 Connector or Direct Cable
Input Voltage+24 Vdc (-15 / +20%)
Polarity Protection-30 Vdc
Overpressure Protection36Vdc
Power consumptionTypically 100 mA or less
Fluctuation< 1 % S-S
Electrical shock quantity500 V (DC ground to mechanical housing ground)

The R-series RP and RH linear magnetostrictive displacement sensors comply with the Profibus-DP (EN 50170) protocol. The sensors transmit position data to the controller in RS-485 standard serial synchronous format, with a high rate of 12 Mbps. The Profibus-DP interface includes the Siemens bus controller SPC3. Additionally, Profibus-DP offers powerful diagnostic and setup functions, which are loaded onto the bus in the form of a GSD electronic instrument data sheet.


Pressure-resistant outer tube dimensions and installation instructions


RH series pressure-resistant outer tube, aluminum profile electronic chamber, designed specifically for hydraulic system use, internally mounted within the hydraulic cylinder. Pressure resistance up to 34MPa continuous (69MPa peak). Thread specifications: M18×1.5, M20×1.5, or 3/4”-16 UNF-3A.

RH Series Profibus-DP Dimensional Drawing

Note: The dead zones shown in the diagram indicate that the sensor outputs are zero or unreliable within this area. The upper and lower dead zone values for this sensor are 50.8 and 63.5mm, respectively. These values can be appropriately adjusted according to customer requirements and should be specifically mentioned to our sales or technical staff when placing an order.


Aluminum Profile External Structure Dimensions and Installation Instructions


RP aluminum extrusion external mounting structure, suitable for general machinery, easy to install and maintain.

RP Series Profibus-DP dimension drawing

Sensor wiring method


When mating aviation connectors, define by the pin and the corresponding wire color.


Waterproof connector directly exiting with wire color definition

PROFIBUS wiring definition