详情描述


Linear value measurement integrated within the hydraulic cylinder


Overall stainless steel round tube sensor


Non-contact measurement, durable and long-lasting


Industrial sensors with harsh environment resistance, EMC interference resistance and CE certification


High precision: Linear deviation less than 0.02%


■ Repeat accuracy up to 0.001%


Direct analog output (V/mA)


■ Measurement Range: 50 ~ 2000 mm


GB Type Displacement Sensor


These compact sealing stainless steel position sensors are specifically designed for hydraulic cylinder installation applications, particularly suitable for U-type head hydraulic cylinders or those with space constraints.


For the widely used standard hydraulic cylinders, the GB type sensor is an excellent choice. A magnetostrictive position sensor, combined with a high-quality cylinder body and control valve, forms a drive system that can meet the technically high standards of the processing industry.


The GB type sensor provides analog current and voltage outputs, as well as forward and reverse measurement functions. The analog output signal is proportional to the magnet's position. The measurement range is factory-set and does not require recalibration. Since it is a direct output, no additional signal conversion circuit is needed when connecting to a controller or meter.


ParametersSpecs
Input
Measurement DataLocation
Measurement Range50 - 5080 mm
Output
Voltage0 ~ 10 Vdc, 10 ~ 0 Vdc, -10 ~ +10 Vdc, +10 ~ -10 Vdc (Controller Low Load: > 5k ohms)
Current4 to 20 mA or 20 to 4 mA (Low/High Load: 0/500 Ohms)
Accuracy
ResolutionInfinite (depending on the controller D/A and power fluctuations)
Non-linearity± 0.02% full scale (fine dust 60 pm)
Repetitive AccuracyFull range ± 0.001% (± 2.5 pm)
Last Updated>1.5 kHz
FluctuationFull Scale (F.S.) Range: 0.01% F.S.
Work Conditions
Magnet SpeedAt will
Operating Temperature- 40 to +75 °C
Foreign exchange pressure350 bar / 700 bar (Peak)
ProtectIP67 ( mating connectors must be tightly locked)
Impact Indicator100 g (Single Impact) / IEC Standard 68-2-27
Oscillator Indicator15 g / 100 - 2000 Hz / IEC Standard 68-2-6 (Durability)
EMC TestingRadiation EN 50081-1, Immunity EN 50082-2, EN 61000-4-2/3/4/6, Class 3/4, Type A, CE Certified
Structure, Material
Electronic HeadStainless Steel 1.4305 / AISI 303
Sensor rod and flangeStainless Steel 1.4301 / AISI 304
Positioning MagnetRing magnet
Installation
Installation LocationAny direction
InstallationStud-bolted flange 0 18H6, 6 bolt holes (ISO 4762 standard)
Electrical Connections
Connector selection6-Pin DIN Connector or Straight Cable (PUR Cable 3 x 2 x 0.25 mm², Φ7.9 mm)
Input Voltage+24 Vdc (-15 / +20%)
Power consumption50 - 140 mA (as per range)
Fluctuation< 1% peak
Electrical Impulse Quantity500 V (DC grounded to machine ground)


GB Type Shell Dimensions and Installation Instructions



Easily installed in any location, with minimal installation space required.


The pressure-resistant stainless steel round tube with an installation flange is secured through the threaded holes of the electronic head with 6 M6*16* A2-70 (ISO4762) screws. A tight seal is achieved using a 15*2 O-ring and a fixing ring.


Hydraulic Installation Diagram Examples


A rod sleeve (such as Teflon) is used to prevent friction between the magnet and the sensor rod. The hole in the piston rod depends on hydraulics and speed, etc. The hole diameter must not be less than 13mm and not exceed the peak pressure of 700bar.



Positioning Magnet


To measure position, secure the magnet using non-magnetic mounting devices (screws, supports, etc.). When the carrier is made of ferromagnetic material, be mindful to use a non-magnetic washer of 5mm thickness and non-magnetic screws for the magnet installation. Note the small installation dimensions shown in the illustration on the right.



Sensor wiring method


When mating aviation connectors, define by pin and corresponding wire color.


Waterproof connectors directly exiting the line, defined by line color


D60 connector pin arrangement (facing the sensor head)


此图像的alt属性为空;文件名为202012300829018.png
Needle sizeLine color Definition
1GrayAnalog Signal Output
2PowderSignal Ground
3HuangCommunication Interface (+)
4GreenCommunication Interface (--)
5Brown +24VDC(-15%/+20%)
6WhiteDirect Current Power Supply接地


Note:


If there's a risk of damaging the straight-through cable during installation, please opt for the connector connection method. The electronic part of the sensor and the straight-through cable are both completely embedded and fixed in the electronic head disc, making repairs to the electronic module difficult. If an issue arises, the entire sensor must be replaced.