详情描述

Robust and durable industrial sensors


Linear Measurement, Output


Sensor with self-diagnosis LED indicator


Non-contact measurement, long service life


High resolution of 1 µm


Non-linearity 0.01%


■ Repeat Accuracy 0.001%


Direct SSI digital output, 24/25/26-bit binary or Gray code


Real-time sensing, synchronized measurement


R-Series Linear Position Sensors


• The R-series RH and RP sensors are extremely robust and durable, making them the ideal choice for stringent industrial environments.


• The R-series offers two standard housing options - the RH type stainless steel outer tube withstands high pressure, suitable for hydraulic cylinder installation. The RP type aluminum molded housing provides accessories for easy machine tool surface installation and various magnet options.


• The sensor incorporates advanced signal processors and a complete output interface circuit. The double shielding of the housing ensures EMI interference protection, enhancing reliability and operational safety levels.

ParametersSpecs
Input
Measurement DataLocation, speed
Measurement RangeRP Aluminum Molding Shell: 50 - 5080 mm; RH Pressure-resistant Outer Tube: 50 - 7620 mm
Output
InterfaceSSI Synchronous Serial Interface or SSI Standard Differential Signal
Data FormatBinary or Gray code, options include parity check and error bit
Data Length8 ~ 32 bits
Data speed70 kBd ~ 1 MBd, depending on cable length: Wire Length: <3 <50 <100 <200 <400 m Speed: 1000 <400 <300 <200 <100 kBd
Last UpdatedTravel: 300, 750, 1000, 2000, 5000 mm; Frequency: 3.7, 3.0, 2.3, 1.2, 0.5 kHz
Accuracy
Resolution1 / 2 / 5 / 10 / 20 / 50 / 100 µm
Non-linearity< Soil content up to full scale 0.01% (Fine soil 50 pm)
Repetitive accuracyFull scale ± 0.001% (± 2.5 pm)
Work Conditions
Operating Temperature- 40 to +75 °C
Humidity / Dew PointHumidity 90%, no condensation
Temperature coefficient< 15 ppm / °C
ProtectRP Aluminum Molding Shell: IP65; Pressure-resistant Outer Tube: IP67 (Connector must be tightly locked) or IP68 (Optional straight-out cable)
Impact Index100 g (Single Impact) / IEC Standard 68-2-27
Oscillator Indicator15 g / 100 - 2000 Hz / IEC Standard 68-2-6 (Durability)
EMC TestingRadiation EN 50081-1, Immunity EN 50082-2, EN 61000-4-2/3/4/6, Class 3/4, Type A, CE Certified
Magnet SpeedAny
Structure, Material
Fault IndicatorElectronic end caps with LED display
RP Aluminum Molding ShellSensor Head: Aluminum, Sensor Rod: Aluminum, Position Magnet: Slider Magnet or Floating Magnet
RH Pressure-resistant Outer TubeSensor Head: Aluminum | Sensor Rod and Flange: 304L Stainless Steel | External Tube Pressure: 350 bar / 690 bar (Peak) | Position Magnet: Ring Magnet, Floating Magnet, or Buoyant Ball
Installation
Installation LocationAny direction
RP Aluminum Molding ShellDetachable fixed clip (to be secured with M5 screws)
RH Pressure-resistant Outer TubeMale threaded flange, Metric M18 x 1.5 or Imperial 3/4" - 6 UNF-3A
Average Locking Force45 N-m
Electrical Connections
Connector selection7 Pin D60 Connector or Direct Cable
Input Voltage+24 Vdc (-15 / +20%)
Polarity Protection-30 Vdc
Overpressure Protection36Vdc
Power consumptionTypically 100 mA or less
Fluctuation< 1 % S-S
Electrical shock quantity500 V (0V connected to mechanical housing)

SSI Synchronous Serial Interface


The sensor meets all the requirements of the output encoder for the SSI standard. Position values are transmitted to the control system at high speed using a 24/25/26-bit encoding pattern. One of the main functions of SSI is synchronous data conversion, which is easily achievable in a closed-loop control system. The controller generates a clock pulse train to activate the sensor data: position data is sent bit by bit to the controller with each clock pulse received by the sensor. The position data is continuously updated within the sensor and then converted into serial information through a shift register.

SSI时序逻辑图
SSI Timing Logic Diagram

Pressure-resistant outer tube dimensions and installation instructions


RH Series pressure-resistant outer tubes, aluminum profile electronic chamber, designed specifically for hydraulic systems use, internally mounted within the hydraulic cylinder, with pressure resistance up to 34MPa continuous (69MPa peak). Available with thread specifications M18×1.5, M20×1.5, or 3/4”-16 UNF-3A.

RH模拟信号
RH Magnetostrictive Sensor SSI Signal

Note: The dead zones shown in the diagram indicate that the sensor outputs are zero or unreliable within this area. The dead zone values for this sensor are 50.8mm and 63.5mm, respectively. These values can be appropriately modified according to customer requirements and can be specially requested from our sales or technical team at the time of ordering.


Aluminum Profile External Structure Dimensions and Installation Instructions


RP aluminum extrusion external mounting structure, suitable for general machinery, easy to install, and convenient to maintain.

RP模拟信号
RP Magnetostrictive Sensor SSI Signal

Sensor wiring method


When connecting aviation connectors, define by the pin and the corresponding wire color.


Waterproof connector direct output, defined by wire color


D70 plug pin arrangement (facing the sensor head)

Needle sizeWire color Definition
1GrayData (-)
2PowderData (Plus)
3HuangClock (+)
4GreenClock (-)
5Brown +24VDC(-15%/+20%)
6WhiteDirect Current Power Supply接地
7
No engagement