详情描述

Import Electric Low-Temperature Regulating Valve

Import Electric Liquid Nitrogen Control Valve, Electric Cryogenic Control Valve, Electric Liquid Oxygen Control Valve, Ultra-Low Temperature Control Valve

Import Electric Low-Temperature Regulating Valve Product Overview

Germany VordWODEImport electric low-temperature regulating valve is made of 3810PSL2SBSeries of electric actuators and ultra-low temperature regulating valve bodies are composed. The actuator contains feeding function and accepts unified4-20mAOr1-5V·DCStandard signal, converting current signals into corresponding linear displacements, automatically controlling the opening of the regulating valve to achieve continuous adjustment of process parameters such as pressure, flow rate, temperature, and liquid level within the pipeline. Electric low-temperature regulating valves are suitable for temperatures below0-250Operates at °C, comprising an electric actuator and a valve body with a long neck pipe. The purpose of the long neck pipe is to enable the valve stem to seal at near room temperature and reduce the transmission of external heat energy. To minimize transmission, the long neck is designed with a thin-walled structure.Section 2: Imported Low-Temperature Electric Regulating Valve Key Technical Parameters

Nominal Bore Size(DN)

20

25

32

40

50

65

80

100

125

150

200

250

300

Valve seat diameter(dn)

20

25

32

40

50

65

80

100

125

150

200

250

300

Rated Flow Coefficient(KV)

Single Seat

6.9

11

17.6

27.5

44

69

110

176

275

440

630

875

1250

Sleeve

6.3

10

16

25

40

63

100

155

250

370

580

900

1300

Permitted Pressure Difference(MPa)

Single Seat

3.8

3.2

3.0

2.0

1.8

1.5

1.4

1.0

0,7

0.6

0.5

0.3

0.1

Sleeve

6.4

6.4

5.2

5.2

4.6

4.6

3.7

3.7

3.5

3.1

3.1

2.6

2.2

Nominal Pressure(MPa)

1.62.54.06.4OrANSI Class150Class600

Rated Stroke(mm)

16

25

40

60

100

Valve cover style

Low-temperature type-10-196Ultra-low temperature type-196-250

Cap Style

Bolt-tensioned

Sealed packing material

VType PTFEVType Flexible Graphite Packing

Valve core style

Single seat, sleeve type

Flow characteristics

Percentage, linear

Configuration Actuator Type

2SBSeries3810SeriesPSLSeries of electric actuators(Customer-specified brands are also accepted.)

Actuator Parameters

Power Voltage:220VInput Signal:4-20mAOr1-5V·DCOutput Signal:4-20mA·DC

Ingress Protection (IP) Rating: EquivalentIP65Explosion-proof marking:ExdBT4(ExdBT6Special Customization)Manual operation function: Handle

Ambient Temperature:-25+70Ambient humidity:≤95%

Note: All products used for liquid oxygen by Word Company have been de-greased and de-oiled, as well as treated at low temperatures.

Section 3: Imported Low Temperature Electric Regulating Valve Structure Diagram

Note: Due to the website layout, please contact Ward's authorized agents for specific dimensions.

Section 4: Imported Low-Temperature Electric Regulating Valve Key Performance Indicators

Project

Index value

Basic Error%

Packing3810L±2.5 MatchPSL±1.0; Matching2SB±1.0

Return difference%

Supplied381L ±2.0 AvailablePSL±1.0Please provide the Chinese content to be translated.2SB±1.0

Dead zone%

1.0

Always Point Deviation%

Electric opening

Starting Point±2.5

End Point±2.5

Origin±2.5

End Point±2.5

Electric shutter

Starting Point

±2.5

End Point

±2.5

Rated stroke deviation%

≤2.5

Leakage volumeL/h

0.01%×Valve rated capacity

Adjustable RangeR

301

Overview of Low Temperature Principle:

Low-temperature valves are mainly used for cutting off, connecting, and regulating the flow of media such as liquid oxygen and liquid nitrogen in pipeline systems under low-temperature conditions. Applicable media temperature range:-196 ~-29 °F, Filling seals are available in both double packing and single packing forms, suitable for different applications. Double packing effectively prevents cold loss, enhancing the sealing effect, ensuring the medium does not leak, and keeping the handwheel at room temperature for smooth operation.-101"Super-low temperature valves with temperatures of 0℃ or below require that the critical components be finely machined after rough processing but before final finishing."100%Immerse-196The liquid nitrogen tank at -196℃ is used for "cryogenic treatment."

If you have any questions.Please call us, and we will certainly go the extra mile to provide you with excellent service! If you need to inquire about more detailed product information, welcome to contact German Vord.WODEAuthorized Level 1 Distributor: Beijing Yongdebao Valve Co., Ltd.