SIEMENS SKD82.50 Imported Valve Actuator_SupplyPro Co., Ltd._Shanghai Luze Energy-Saving Technology Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》

SIEMENS SKD82.50 Imported Valve Actuator

产品Price Negotiable

最小起订Quantity:100 Tai 供货总Quantity: 100000 Tai

用手机扫描二维码直达商品手机版
MobileView details
Location:
Shanghai
有效期至:
长期有效
最后更新:
2022-08-06 14:53
Product Details

Electric hydraulic valve actuators SKD32...SKD82...SKD62...SKD60
20mm Journey
• SKD32...: Operating voltage is AC 230V, three-position control signal
• SKD82...: Operating voltage AC 24V, three-position control signal
• SKD6…: Operating voltage is AC 24V, DC 0-10V, 4-20mA, or 0-1000Ω valve signal
• SKD6...: Selectable flow characteristics, valve position feedback, stroke adjustment, LED status indication, priority control
• SKD62UA: Features include selective action direction, stroke limit control, adjustable starting point and stroke range sequence control, and additional freeze protection monitoring signals such as QAF21... and QAF61...
• Drive force up to 1000 N
• With or without spring return function
• Directly mounted on the valve, no adjustment required
• Manual adjustment and position indicator features
• Functionality can be enhanced with additional auxiliary switches, potentiometers, valve stem heaters, and stroke inverters.
• SKD...U UL Certified
Application
For Siemens two-way and three-way valves of the VVF... series, VVG… series, VXF… series, and VXG... series, with a drive stroke of 20 mm, suitable for use in HVAC systems as control valves or safety shut-off valves.
Engineering Precautions
The actuator's electrical connections must comply with local electrical installation regulations and internal wiring diagrams. To ensure personal and property safety, it is mandatory to adhere to the relevant safety regulations and restrictions! An ASZ6.5 rod heater must be used when the medium temperature is below 0°C to prevent valve freezing. For safety reasons, the rod heater is designed for AC 24V/30W.
The actuator bracket and valve rod cannot be separated to ensure air circulation. Do not touch hot components without protective measures to avoid burns.
Failure to comply with the above suggestions may result in accidents or fires.
Recommendation: Strongly recommend isolating the valve when the temperature exceeds 140 °C.

询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

Phone Consultation

Consultation Phone:
13127599922

Back to Top