Firefighting equipment, electronic products, refrigeration equipment, environ...
产品Price Negotiable
最小起订Quantity:1 Individual 供货总Quantity: 10000 Individual
Is Importing |
|
Usage |
Fire Extinguisher |
Is the supply cross-border? |
No |
Customized Processing |
Unsupported |
Available Locations |
National |
Specs |
Comprehensive |
Water Cannon Online Promotion Article 1. The Automatic Tracking and Locating Jet Fire Extinguishing Device is a high-tech fire protection product developed through the technological innovation alliance of the second-generation fire cannon technology, integrating automatic alarm, fire tracking, automatic extinguishing, and video surveillance into one. 2. The automatic tracking and positioning jet fire extinguishing device leads with patented infrared thermal imaging positioning technology. In addition to the industry-standard first-generation active red and ultraviolet single-point narrow-slot technology for detecting fire sources, it features automatic positioning and targeted water jetting at the fire point for extinguishing. After extinguishing, it automatically closes the valve, and if reignition occurs, it restarts. Moreover, it boasts real-time dynamic tracking of changing fire sources, ensuring more accurate positioning. 3. The automatic tracking and positioning jet fire suppression system is suitable for applications where general fire monitors are not ideal, such as environments with UV lights, welding, or outdoor cutting areas. It is also ideal for locations that demand high accuracy in positioning and system reliability, requiring round-the-clock, fully automatic operation. 4. The automatic tracking and positioning jet fire extinguishing device is easy to install, with simple water and power supply, low maintenance costs, water conservation, and significantly reduces the risk of flood damage after extinguishing. It offers high cost-performance ratio and is widely used in high and large spaces such as cinemas, warehouses, factories, stadiums, grand halls, waiting halls, exhibition centers, hotels, and parking lots. 5. Automatic tracking and positioning jet fire suppression systems are not suitable for environments where open flame production is normally used. 6. Automatic tracking and定位 jet fire suppression devices are not suitable for Class B, C, or D fire conditions. 7. Automatic tracking and positioning jet fire suppression systems are not suitable for locations with a high number of items that accelerate combustion when wet. 8. Automatic tracking and positioning jet fire extinguishing devices are not suitable for locations where water causes explosions. 9. Automatic tracking and positioning jet fire suppression systems are not suitable for areas containing items that undergo vigorous chemical reactions or produce toxic substances when exposed to water. 10. Automatic tracking and positioning jet fire suppression systems are not suitable for areas where liquid splash or boil-over may occur due to sprinkling. 11. Automatic tracking and positioning jet fire suppression systems are not suitable for locations containing valuable items that would sustain severe damage upon contact with water, such as archives, valuable records repositories, and museum珍品rooms. 12. Automatic tracking and positioning jet fire extinguishing devices are not suitable for locations where significant property damage is caused by high-altitude water cannons. 13. Automatic tracking and positioning jet fire suppression systems are not suitable for other locations where large-space active water sprinkler fire suppression systems should not be used. 14. The Automatic Tracking and Locating Jet Fire Extinguishing Device is an integrated automated and intelligent fire extinguishing system that combines computer technology, red and ultraviolet sensing technology, infrared thermal imaging technology, mechanical transmission technology, and image transmission technology. It actively detects the monitored area around the clock in an all-weather, fully automatic manner. 15. The automatic tracking and positioning jet fire extinguishing device, upon detecting a fire, promptly activates and emits an alarm signal. It simultaneously engages the solenoid valves and water pumps to extinguish the fire source by jetting water. After the fire is extinguished, it automatically stops. In case of re-ignition, it restarts. 16. The automatic tracking and positioning jet fire extinguishing device can be connected to the automatic fire alarm system and can also be integrated with on-site operation panels, fire monitor controllers, etc., to form a centralized fire extinguishing system. 17. The automatic tracking and positioning jet fire suppression system is easy to install, with simple water and power supply, low maintenance costs, saves water resources, and greatly reduces the risk of water damage after fire suppression. 18. The automatic tracking and positioning jet fire suppression device utilizes the technical principle of missile guidance with air-to-air missiles. The core components employ infrared thermal imaging sensors and array scanning positioning principles. In addition to general civil applications, it is also suitable for complex industrial warehouse environments, certain outdoor settings, or locations with high reliability requirements for the system. 19. The Automatic Tracking and Positioning Jet Fire Extinguishing Device abandons narrow-slot technology, adopting the same principle as the real-time tracking of the heat signature of the leading aircraft's exhaust plume by air-to-air missiles. Its core technology utilizes uncooled focal plane array thermal imaging sensors with real-time temperature measurement capabilities. The core positioning technology is a combination of thermal imaging sensors and inertial navigation = real-time tracking technology. 20. The automatic tracking and positioning jet fire suppression device uses a surface thermal imaging array sensor for scanning during fire detection. Each pixel's temperature is calculated in real-time. Once detected, it locks on immediately, tracks the dynamic fire source in real-time, analyzes the fire source situation intelligently, and then targets the fire source for water spraying, featuring safety, reliability, and convenience. 21. The core positioning component of the automatic tracking and positioning jet fire suppression device uses a non-cooled focal plane array thermal imaging sensor. 22. The Automatic Tracking and定位 jet fire extinguishing device, in addition to the spot-type wide-angle ultraviolet flame detector, is activated by a thermal imaging sensor for temperature measurement, ensuring no false alarms. 23. Automatic tracking and positioning jet fire suppression system with thermal imaging + inertial guidance = real-time tracking; upon detection, immediately lock onto and track the dynamic fire source in real-time. 24. Automatic tracking and positioning jet fire suppression device with laser red dot aiming, shoot where you aim, a more reliable human-machine integration. 25. The main unit of the automatic tracking and positioning jet fire extinguishing device is equipped with a remote rod for real-time stepless speed control of the water cannon. It can aim where you point, and can be used as a fast-motion video monitoring camera in normal times. 26. The automatic tracking and positioning jet fire suppression device features a fully sealed moving part, dust-proof, and can long-termly remain in automatic standby to protect the safety of the site. 27. The automatic tracking and positioning jet fire extinguishing device can be individually set to the automatic or manual status of four modes: water cannon, valve, pump, and laser, for easy management. 28. The automatic tracking and positioning jet fire suppression unit's main unit can set weekly calendar periods for each cannon, scheduling automatic switching between manual and automatic water cannon functions. 29. The main unit of the automatic tracking and positioning jet fire extinguishing device can not only operate the water cannon and view and adjust the parameters of the water cannon but also remotely update the program for convenient maintenance and repair. 30. The core positioning component of the automatic tracking and positioning jet fire extinguishing device utilizes non-cooled focal plane infrared thermal imaging technology for image scanning. Once locked, it can track the dynamic fire source in real-time. 31. The Automatic Tracking and Positioning Jet Fire Extinguishing System integrates three control methods: fire automatic alarm, on-site manual control, and centralized control in the control room. 32. The automatic tracking and positioning jet fire suppression device water cannon controller features a Chinese character color LCD touch screen and an integrated printer for real-time alarm printing. 33. The automatic tracking and positioning jet fire extinguishing device comes with a four-axis remote杆 for easy remote control of the water cannon's up, down, left, and right movements. 34. The Automatic Tracking and定位 Jet Fire Extinguishing Device System features a timed conversion function. For each fire extinguishing device, multiple time periods can be set, and the system automatically completes the manual to automatic conversion of the water cannon at the scheduled times. 35. The automatic tracking and positioning jet fire suppression system is equipped with automatic interlock functionality. It allows for automatic interlock between water cannons within the protected area, enabling one alarm to activate the entire system. 36. The automatic tracking and positioning jet fire suppression device can be individually set to the automatic or manual status of four modes: water cannon, valve, pump, and sound and light, for easy management. 37. Each area exit of the automatic tracking and positioning jet fire extinguishing device allows for the observation of all fire hoses within the zone. An on-site operation panel is installed to control all water spray fire extinguishing settings within the area. It displays the cannon selection, communication, audible and visual alarms, device fault indication, and silence status in Chinese LCD format. Functional operations such as up, down, left, right directions, valve and pump on/off are performed through buttons. The on-site operation panel should be installed at a height of 1.5 meters from the ground, with no obvious obstructions around. 38. The water cannon controller of the automatic tracking and positioning jet fire extinguishing device allows for remote viewing and debugging of all parameters, and can remotely update the program for the water cannon. The operating parts of an automatic tracking and positioning jet fire extinguishing device should be fully sealed, with no gears visible at the openings to prevent dust from entering and affecting its long-term stable operation. 40. The fire extinguishing components of an automatic tracking and positioning jet fire suppression system should be integrated with a laser red dot indicator for easy verification of the accuracy of positioning at any time. 41. The automatic tracking and positioning jet fire suppression system utilizes masterless bus communication technology. A single loop supports up to 9999 bus devices, with the first two digits representing the zone number and the last two digits indicating the cannon number. 42. The automatic tracking and positioning jet fire extinguishing device features a single outlet, which concentrates water flow, boasts strong penetration power in fire scenes, is less prone to atomization, and provides excellent results in extinguishing early-stage fires. 43. The signal bus for the automatic tracking and positioning jet fire extinguishing device must be a daisy-chain structure; no branches are allowed. 44. The video line for the automatic tracking and positioning jet fire suppression system is point-to-point structured. Each water cannon has a separate video line that is directly pulled to the video host. When the distance exceeds 300 meters, optical fiber transmission should be used, and a photoelectric repeater should be added for transmission. 45. The automatic tracking and positioning jet fire suppression system circuitry is laid using metallic pipes or conduits. Conductors of different systems and voltages must not share the same pipe or conduit. The power supply for the system should use AC220 fire-resistant power supply; power should not be drawn from the nearest source. 46. Each fire compartment in the installation site of an automatic tracking and positioning jet fire extinguishing device should be equipped with at least one on-site operation panel. Connected via CAN bus, the main unit remotely monitors the fire scene in conjunction with the on-site video surveillance system, enhancing the functionality of联动 decision management. 47. Fire hoses with automatic tracking and positioning jet fire suppression, on-site operation panels, and intelligent end-of-line test devices, each occupies a single bus address point. They are all connected in parallel to the CAN bus without any branching in between. 48. The video line for the automatic tracking and positioning jet fire extinguishing device uses the same wiring method as the security system, i.e., a video line is laid from the video host to each fire extinguishing device. The video line should be a SYV75-5 cable. When the length of the video line exceeds 300 meters, optical fiber transmission should be used for the video signal. 49. To connect the water cannon of an automatic tracking and positioning jet fire extinguishing device to a fire alarm system, simply add an input module to the passive alarm terminal of each water cannon's electrical control box to upload the water cannon's alarm signal to the fire alarm system; adding an input/output module will enable the fire alarm联动 activation of the water cannon. 50. The water cannon of the automatic tracking and positioning jet fire suppression system can be installed by overhead, suspended, or wall-side methods. Regardless of the installation method, ensure the nozzle is vertically downward and freely rotating. A vertical DN50 flange is pre-installed 50cm away from the wall or other obstacles at the end of the water pipeline. Use a rubber flat washer for sealing; metal washers are strictly prohibited. During installation, temporarily install two downward bolts on the upper flange first. Once the nozzle is in place, secure the water cannon with two nuts, then place the flat washer, and thread it into the upper flange's holes from above. Tighten the nuts on top, then adjust the original downward bolts to face upward and tighten them.

Phone Consultation