Firefighting equipment, electronic products, refrigeration equipment, environ...
产品Price Negotiable
最小起订Quantity:1 Piece 供货总Quantity: 10000 Piece
Is Importing |
|
Application |
Fire Extinguisher |
Is cross-border sourcing available? |
No |
Customized Processing |
Not supported |
Available Markets |
National |
Specs |
Complete |
Water Cannon Network Promotion Article 1. The Automatic Tracking and Locating Jet Fire Extinguishing Device is a high-tech fire protection product developed based on the innovative technology alliance of the second-generation fire cannon, integrating automatic alarm, fire tracking, automatic extinguishing, and video surveillance into one. 2. The Automatic Tracking and Locating Jet Fire Extinguishing Device leads with patented infrared thermal imaging localization technology. In addition to featuring the industry-standard first-generation active red and ultraviolet single-point narrow slit technology for fire source detection, automatic localization, and targeted water jetting at the fire point for extinguishing, it also automatically closes the valve post-extinguishing and restarts in case of reignition. Furthermore, it boasts real-time dynamic tracking for changing fire sources, providing more accurate localization. 3. The automatic tracking and positioning jet fire suppression system, in addition to being suitable for general fire lance applications, can also be used in environments where UV lights, welding, and outdoor cutting areas are present, where conventional fire hoses are not ideal. It is also suitable for locations that demand high precision in location and system reliability, requiring round-the-clock, fully automatic operation. 4. The automatic tracking and positioning jet fire extinguishing device is easy to install, with simple water and power supply, low maintenance costs, water-saving, and greatly reduces the risk of flood after fire. It offers high cost-performance and is widely used in high and large spaces such as cinemas, warehouses, factories, stadiums, grand halls, airport lounges, convention centers, hotels, and parking lots. 5. Automatic tracking and positioning jet fire suppression devices are not suitable for environments where open flame production is normally employed. 6. Automatic tracking and positioning jet fire suppression systems are not suitable for Class B, C, or D fire situations. 7. Automatic tracking and positioning jet fire suppression devices are not suitable for areas containing a large number of items that burn faster when wet. 8. Automatic tracking and positioning jet fire extinguishing devices are not suitable for areas where explosion occurs upon contact with water. 9. Automatic tracking and定位 jet fire suppression systems are not suitable for areas where items undergo intense chemical reactions or produce toxic substances when in contact with water. 10. Automatic tracking and positioning jet fire suppression systems are not suitable for areas where liquid spattering or boiling over may occur due to sprinkling. 11. Automatic tracking and positioning jet fire extinguishing devices are not suitable for locations housing valuable items that would sustain severe damage upon contact with water, such as archives, valuable document libraries, and museum collections. 12. Automatic tracking and positioning jet fire suppression systems are not suitable for locations where significant property damage is caused by the impact of high-altitude water cannons. 13. Automatic tracking and positioning jet fire extinguishing devices are not suitable for other locations where large-scale active water spray fire extinguishing systems are not recommended. 14. The Automatic Tracking and Locating Jet Fire Extinguishing Device is an integrated automated and intelligent fire extinguishing system that combines computer technology, red and ultraviolet sensing technology, infrared thermal imaging technology, mechanical transmission technology, and image transmission technology. It actively detects the monitored area around the clock in an all-weather, fully automatic manner. 15. The automatic tracking and positioning jet fire suppression device, upon detecting a fire, promptly activates and simultaneously sends an alarm signal. It then联动electromagnetic valves and water pumps to extinguish the fire source with water. Once the fire is extinguished, it automatically shuts off. If the fire reignites, it restarts. 16. The automatic tracking and positioning jet fire extinguishing device can be connected to the automatic fire alarm system and can also be integrated with on-site operation panels, fire monitor controllers, etc., to form a centralized fire extinguishing system. 17. The automatic tracking and定位 jet fire extinguishing device is easy to install, with simple water and power supply, low maintenance costs, saves water resources, and greatly reduces the risk of flood damage after extinguishing. 18. The Automatic Tracking and Positioning Jet Fire Extinguishing Device utilizes the technology principle of air-to-air missile tracking guidance. Its core components employ infrared thermal imaging sensors and array scanning positioning principles. It is suitable for general civil sites, as well as complex industrial warehouses, certain outdoor environments, or locations with high reliability requirements for the system. 19. The Automatic Tracking and Locating Jet Fire Extinguishing Device abandons the narrow slit technology, adopting the same principle as the real-time tracking of the heat signature of the leading aircraft's exhaust plume by air-to-air missiles. The core technology utilizes a non-cooled focal plane array thermal imaging sensor, featuring real-time temperature measurement capabilities. The core positioning technology is a combination of thermal imaging sensor + inertial navigation = real-time tracking technology. 20. The automatic tracking and positioning jet fire suppression device uses a surface thermal imaging array sensor for scanning to locate fires. Each pixel's temperature is calculated in real-time. Once detected, it locks on immediately, tracks the dynamic fire source in real-time, intelligently analyzes the fire source situation, and then aims to spray water at the fire source, featuring safety, reliability, and convenience. 21. The core positioning component of the automatic tracking and positioning jet fire suppression system utilizes a non-cooled focal plane array thermal imaging sensor. 22. The automatic tracking and positioning jet fire suppression system, in addition to the spot-type wide-angle ultraviolet flame detector, also utilizes thermal imaging sensors for temperature measurement activation, ensuring no false alarms. 23. Automatic Tracking and Locating Jet Fire Extinguishing Device with Thermal Imaging + Inertial Navigation System = Real-time Tracking; upon detection, immediately lock on and track the dynamic fire source in real-time. 24. Laser red dot indicator for automatic tracking and positioning jet fire suppression system, aiming where it fires, a more reliable man-machine integration. 25. The main unit of the automatic tracking and positioning jet fire extinguishing device is equipped with a remote rod for real-time stepless speed control of the water cannon. It can aim where you point, and can also be used as a quick ball for video surveillance during normal times. 26. The automatic tracking and positioning jet fire suppression device features full-sealed moving parts, dust-proof, and can be long-term ready for automatic operation to protect the safety of the premises. 27. The automatic tracking and positioning jet fire suppression device can be individually set to the automatic or manual status of four modes: water cannon, valve, pump, and laser, facilitating management. 28. The main unit of the automatic tracking and positioning jet fire suppression device can set weekly time periods for each cannon, enabling timed automatic switching between manual and automatic water cannon functions. 29. The main unit of the automatic tracking and positioning jet fire extinguishing device can not only operate the water cannon and view and adjust its parameters, but also remotely update the program for convenient maintenance and repair. 30. The core positioning component of the automatic tracking jet fire extinguishing device utilizes non-cooled focal plane infrared thermal imaging technology, providing image-based scanning. Once locked on, it tracks the dynamic fire source in real-time. 31. The automatic tracking and positioning jet fire extinguishing system integrates three control methods: fire automatic alarm, on-site manual control, and centralized control in the central control room. 32. The automatic tracking and positioning jet fire extinguishing device's water cannon controller features a Chinese character LCD color touch screen and an integrated printer for real-time alarm printing. 33. The automatic tracking and positioning jet fire extinguishing device comes with a four-axis remote rod for easy remote control of the water cannon's up, down, left, and right movements. 34. The Automatic Tracking and Locating Jet Fire Extinguishing Device System features a timed conversion function. Multiple time periods can be set for each fire extinguishing device, and the system automatically completes the hand-to-automatic conversion of the water cannon at the set times. 35. The automatic tracking and positioning jet fire suppression system features automatic interlocking functionality, enabling the water cannons within the protected area to interlock automatically. One alarm triggers the activation of all. 36. The automatic tracking and positioning jet fire extinguishing device can be individually set to the automatic or manual status of four modes: water cannons, valves, water pumps, and sound and light, for convenient management. 37. Each area's exit inner side of the automatic tracking and positioning jet fire suppression device can observe all fire hoses within the area. An on-site operation panel is installed to control all water spray fire suppression settings within the area. It displays nozzle selection, communication, sound and light alarm, device fault display, and silence status in Chinese LCD format. Functions such as up, down, left, right direction, valve opening and closing, and pump opening and closing are operated through buttons. The on-site operation panel should be installed at a height of 1.5 meters from the ground and should be free of obvious obstructions. 38. The water cannon controller for the automatic tracking and positioning jet fire suppression system allows for remote viewing and adjustment of all parameters, as well as remote updating of the water cannon's software. The operating components of the automatic tracking and positioning jet fire extinguishing device should be fully sealed; no gears should be visible at the openings to prevent dust from entering and affecting its long-term stable operation. 40. The fire suppression components of an automatic tracking and locating jet fire suppression system should be integrated with a laser red dot indicator for easy verification of correct location at any time. 41. The automatic tracking and positioning jet fire extinguishing device employs masterless bus communication technology. A single loop supports up to 9999 bus devices, with the first two digits representing the zone number and the last two digits representing the cannon number. 42. The automatic tracking and positioning jet fire extinguishing device features a single outlet, concentrating water flow for strong penetration in fire scenes, reducing atomization, and providing effective early fire extinguishing. 43. The signal bus for the automatic tracking and positioning jet fire suppression device must be a daisy chain structure, with no branches. 44. The video line for the automatic tracking and positioning jet fire suppression device is point-to-point structured. Each water cannon has a separate video line that directly connects to the video host. When the distance exceeds 300 meters, fiber optic transmission should be used, and an optical-electrical repeater should be added for transmission. 45. The automatic tracking and positioning jet fire extinguishing system uses metal pipes or metal conduit trays for wiring. Different systems and different voltage wires must not share the same conduit or tray. The power supply for the system should be from an AC220 fire protection power source, and electricity should not be drawn from nearby. 46. Each fire compartment in the installation site of an automatic tracking and positioning jet fire extinguishing device should be equipped with at least one on-site operation panel. Connected via CAN bus, the host remotely monitors the fire scene with the cooperation of the on-site video surveillance system, enhancing the functionality of联动 decision management. 47. Fire hoses with automatic tracking and positioning jet fire suppression, on-site operation panels, and intelligent end-of-line test devices each occupy a single bus address point. They are all connected in parallel to the CAN bus without any branches in between. 48. The video line for the automatic tracking and positioning jet fire suppression system is laid in the same manner as the security system, with a video line running from the video host to each fire suppression unit. The video cable should be of type SYV75-5. When the length of the video line exceeds 300 meters, it should be transmitted using fiber optics. 49. To connect the water cannon of an automatic tracking and positioning jet fire suppression system to a fire alarm system, simply add an input module to the passive alarm terminal of each water cannon's electrical control box to upload the water cannon alarm signal to the fire alarm system; adding an input/output module will enable the联动 activation of the fire alarm with the water cannon. 50. The water cannons of the automatic tracking and positioning jet fire suppression device can be installed by overhead, suspended, or wall-side methods. Regardless of the installation method, ensure the cannon head is vertically downward with free rotation. A DN50 flange facing downward is pre-installed at 50cm from the wall or any obstacle. Use a rubber flat washer for sealing; metal washers are strictly prohibited. During installation, temporarily install two downward bolts on the upper flange first. Once the cannon head is close, secure the water cannon with two nuts, then place the flat washer. Thread the nuts upwards into the opposite screw holes, tighten the nuts on top, and finally adjust the original downward bolts to face upwards and tighten them.

Phone Consultation