Direct Fire Detection Tube Sales

产品Price Negotiable

最小起订Quantity:1 Unit 供货总Quantity: 1000 Unit

用手机扫描二维码直达商品手机版
MobileView details
Location:
Hebei/Shijiazhuang
有效期至:
长期有效
最后更新:
2023-05-25 14:39
Product Details

Is importing

Application

Fire Extinguisher

Is the supply cross-border?

No

Customized Processing

Not supported

Available for sale locations

National

Specs

Comprehensive

1. The flame tube type automatic fire extinguishing device is a more scientific and reasonable fire extinguishing system. It utilizes flexible non-metallic flame tubes as both fire detection and extinguishing agent discharge elements, operates without any power source, and combines fire detection with extinguishing capabilities. It is a product encouraged by the National Development and Reform Commission for the industrial upgrade during the 13th Five-Year Plan period.

2. The flame tube type automatic fire extinguishing device does not require any power or traditional electrical control. It relies solely on the material of the flame tube itself to accurately detect fires through physical sensing and then extinguish them. This eliminates false alarms and unintended activations caused by electromagnetic interference, smoke, oil stains, humidity, and human errors, making it more convenient, stable, and reliable.

3. The flame detection and automatic fire extinguishing device with a flexible non-metallic probe tube can be installed close to the fire-prone areas inside the equipment, unlike traditional fire protection systems where detection and extinguishing agents are placed at the top of the building, far from the actual fire source. This allows for timely fire detection and precise, rapid point-to-point extinguishing, making it a true early fire suppression system.

4. The fire tube type temperature-sensing automatic fire extinguishing device transforms the traditional gas fire extinguishing system from a full flooding method for the entire building interior to a localized flooding method for only the fire-prone equipment within the building. This results in a reduction of fire extinguishing agent usage by over 80%, and eliminates the need for complex piping networks, cylinder storage rooms, and electronic control equipment. It also significantly reduces the weight and space occupied by the fire extinguishing device, as well as the potential harm of the extinguishing agent to the environment and personnel.

5. Fire tube type automatic fire extinguishing devices, according to the functions of the fire tube, can be divided into two types: "Direct Fire Extinguishing Devices" and "Indirect Fire Extinguishing Devices." Devices with fire tube that combines both fire detection and extinguishing agent discharge are known as "Direct Fire Extinguishing Devices"; those with fire tube that only has fire detection function, and the extinguishing agent discharge is completed by another release tube, are categorized as "Indirect Fire Extinguishing Devices."

6. The direct extinguishing device in the flame-detecting pipe-type automatic fire extinguishing system is composed of flexible flame-detecting pipes installed inside the protected equipment. In the event of a fire, the flame-detecting pipe closest to the fire source heats up, softens, and bursts, causing a loss of pressure inside the pipe. This pressure drop opens the valve of the container, releasing the fire extinguishing agent from the container into the burst pipe, directly spraying towards the fire source to extinguish it quickly in the initial stage. Mainly used for protecting enclosed equipment with a volume of 6m³ or less.

7. Indirect fire suppression system in the flame detection pipe type automatic fire extinguishing device. The flexible flame detection pipe is arranged in the fire detection area. Once a fire occurs, the flame detection pipe closest to the fire source heats up, softens, and bursts, causing a loss of pressure inside the pipe. This pressure loss causes the container, which is closed by pressure balance, to open. The fire extinguishing agent in the container is then released through a separate discharge pipe and sprayed into the protected space through nozzles to extinguish the fire. Mainly used to protect spaces of 60m³ or less and equipment without casings.

8. The fire tube type automatic fire extinguishing device with temperature sensing is suitable for microwave rooms, decimeter wave rooms, transformer substation rooms, and uninterruptible power supply rooms within broadcast and television transmission towers.

9. Communication rooms, control rooms, and signal transfer points for the fire tube type temperature-sensing automatic fire extinguishing system, railway control rooms, and signal stations.

10. The flame tube type automatic fire extinguishing device with temperature sensing is suitable for power generation equipment such as thermal, hydroelectric, and wind power plants, various control rooms, electronic equipment rooms, computer rooms, relay rooms, transformer substations (cabinets), transformers, cable intersections, elevator control cabinets, grooved cable trays or bridges for electrical cables.

11. The fire tube type automatic fire extinguishing device with temperature sensing is suitable for CNC machine rooms, precision equipment, automobiles, trains, subways, ships, and other means of transportation.

12. Fire tube type automatic fire extinguishing devices with temperature sensing are suitable for commercial kitchens, library facilities, flammable goods storage, and other warehouses, as well as for special or critical equipment cabinets in various locations.

13. The flame detection and automatic fire extinguishing system is composed of a pressure vessel containing extinguishing agent, container valves, and flame detection tubes and/or release tubes capable of releasing the extinguishing agent.

14. Position the flame detection and automatic fire extinguishing device with a thermosensitive tube near or above the potential fire source. Simultaneously, rely on the numerous detection points (linear) along the flame detection tube for sensing. In the event of a fire, the flame detection tube softens at the heated temperature and releases the extinguishing medium either through the tube itself (direct system) or through nozzles (indirect system) into the protected area.

15. The flame tube type automatic fire extinguishing device is a new variety developed in the high-tech field and a high-tech non-metallic synthetic product. It combines long-term leakage resistance, flexibility, and effective temperature sensitivity into one, and can spray fire extinguishing medium or transmit fire signals within a certain temperature range.

16. The fire probe-style automatic fire extinguishing device, commonly known as "fire probe," is a small, fixed automatic gas fire extinguishing system; it is an automatic gas fire extinguishing system that accurately detects the fire source, extinguishes fires in their incipient stage, and combines both detection and extinguishing functions.

17. The flame tube type automatic fire extinguishing device is a targeted, point-to-point, and close-protection automatic gas fire extinguishing system designed for fire-prone areas or critical facilities.

18. The flame detection tube-type automatic fire extinguishing device is an easy-to-install, versatile, battery-free, and highly reliable automatic gas fire extinguishing system.

19. The technical features of the fire-tube type automatic fire extinguishing device include: the fire probe is a flexible material, unaffected by any position, and can be inserted into various narrow and complex flammable spaces or equipment, which is something that other fire extinguishing facilities cannot achieve.

20. The flame-detection tube-type automatic fire extinguishing device is equivalent to a linear detector, with any point on it capable of detecting the fire source. It bursts and releases the extinguishing medium near the fire source, closely contacting the protected object. It combines fire detection and extinguishing, resulting in a fast system response. It can quickly extinguish fires at their nascent stage, effectively reducing economic losses caused by fires, and facilitating rapid production recovery.

21. The fire tube type automatic fire extinguishing device operates without power, is not affected by electromagnetic interference, vibration, or impact, and is not weakened in fire detection function nor causes false operation due to environmental factors like smoke, dust, humidity, etc. Easy to install and maintain, with low operation costs. It is not a full flooding system in the building space, so it won't harm on-site personnel during release. Suitable for unmanned, high-priority protection equipment and areas.