





















价 格¥850.00
最小起订0 tons库存0 tons
Surveillance Camera Tower
¥868.00/tons
Corner surveillance tower
¥860.00/tons
Monitor Tower
¥863.00/tons
Angle steel power tower
¥846.00/tons
Power Infrastructure
¥865.00/tons
Surveillance Tower
¥865.00/tons
Four-column angle steel monitorin
¥859.00/tons
110KV Power Infrastructure
¥856.00/tons
Chimney Tower
¥856.00/tons
Forest Fire Watchtower
¥850.00/tons



Design Principles of Training Tower: Facilitate duty readiness, military and officer training, enhance the combat effectiveness of the team, and meet the needs of safeguarding modern construction and the safety of people's lives and property. Design Aims of Training Tower: Scientific and practical.
Fire training towers should meet the following requirements:
One, the training tower should be situated near the end of the training field with a reserved runway, and a 1.5-meter sand pit in front of the tower.
The training tower should have at least four stories, and in cities with a high number of high-rise buildings, the number of stories may be appropriately increased.
Section 3: Each floor of the training tower's front has at least two windows, with a width between the windows (and the wall) of 1.0 meter.
Four. The training tower window size is 1.2m x 1.8m, the distance from the window to the tower edge must not be less than 0.65m, the window sill width is 0.4m, the window sill plate thickness is 0.05 (protruding 5cm from the tower wall), the height of each window sill from the ground level of the same floor is 0.8m, the floor height is 3.5m, and there should be an inner staircase with a minimum clear width of 0.7m, with handrail tube diameter not less than 0.042m.
V. On each level inside the training tower, a platform at least 1.5 meters wide should be provided, and a floor should be set on the top level.
Six, the training tower should be equipped with an outdoor fire escape ladder. The ladder should lead to the top of the tower and ideally be set at a height of 3 meters above the ground, with a width not less than 60 centimeters. Training Tower Description: 1. Mainly composed of (1) simulated windows, (2) floor partitions, (3) rear frames, (4) observation and command platform frames, and the main steel structural frame. Simulated windows are installed at the front of the tower (custom-made with a specific number of floors and windows as needed), with floor partitions (steel plates) between the upper and lower adjacent simulated windows. 2. A rear frame corresponding to the simulated windows is located below the rear of the tower. 3. The simulated windows, floor partitions, rear frames, and main frame are bolted together. 4. Safety ladders connect between each floor. 5. The upper part of the tower is equipped with an observation and command platform.
Seven: Training towers typically undergo anti-corrosion treatment with spray painting, in a military green color. Alternatively, camouflage patterns or galvanizing are available.
Section 8: Our steel structure fire training towers are fully functional, featuring detachable and portable designs that are not limited by location, terrain, or land plots. Made with assembled components, they offer low cost and high recyclability, helping to save expenses and achieve twice the results with half the effort. Welcome fire departments to order our fire training towers.











Phone Consultation