















































































价 格¥855.00
最小起订0 ton库存0 ton
Grassland Fire Monitoring Tower
¥853.00/ton
Angle steel lightning rod tower
¥866.00/ton
Bouldering Training Tower
¥853.00/ton
Forest Fire Observation Tower
¥850.00/ton
Monitor Tower
¥863.00/ton
Communication Line Power Poles
¥855.00/ton
Substation power framework
¥858.00/ton
Power Grid Infrastructure
¥852.00/ton
Customized Chimney Towers
¥852.00/ton
Chimney Iron Tower
¥858.00/ton



Design Principles of Training Tower: Facilitate duty readiness, soldier and officer training, enhance the combat effectiveness of the team, and meet the needs of safeguarding modern construction and the safety of people's lives and property. Design Aims of Training Tower: Scientific and practical.
Fire training towers should meet the following requirements:
One, the training tower should be situated at the end of the training ground with a reserved runway, and a sand pit of 1.5 meters in front of the tower.
The training tower should have at least four floors, with the number of floors appropriately increased in cities with a high number of high-rise buildings.
Three, each floor of the training tower's front window shall have no fewer than two windows, with a width of 1.0 meter between the windows (and the wall).
Four, the dimensions of the training tower window are 1.2 meters by 1.8 meters, and the window must be at least 0.65 meters from the tower's edge. The window sill width is 0.4 meters, with a sill board thickness of 0.05 meters (protruding 5 centimeters from the tower wall). The height of each window sill from the floor level of the same floor is 0.8 meters, the floor height is 3.5 meters, and an internal staircase with a clear width of at least 0.7 meters should be provided, with the handrail tube diameter not less than 0.042 meters.
Five, An unobstructed platform of not less than 1.5 meters in width should be set on the inner side of each floor of the training tower, and a floor should be installed on the top floor.
Section 6: The training tower should be equipped with an outdoor fire escape ladder. The ladder should extend to the top of the tower and ideally be set up at a height of 3 meters from the ground, with a width not less than 60 centimeters. Training Tower Description: 1. Mainly composed of (1) simulated windows, (2) floor partitions, (3) rear frames, (4) observation and command platform frames, and the main steel structural frame. Simulated windows are installed at the front of the tower (customized to have several floors and windows as needed), with floor partitions (steel plates) between the upper and lower simulated windows. 2. A rear frame corresponding to the simulated windows is located below the rear of the tower. 3. The simulated windows, floor partitions, rear frames, and main frame are connected together with bolts. 4. Each floor is connected with a safety staircase. 5. The upper part of the tower is equipped with an observation and command platform.
Seven, Training towers are typically coated with spray paint, in military green. Or camouflaged, and zinc-plated.
Section 8: Our steel structure fire training towers are fully functional, featuring detachable and portable designs that are not restricted by geography, terrain, or land plots. Made with assembled components, they offer low cost and high recyclability, helping to save expenses and achieve twice the results with half the effort. Welcome fire departments to order our fire training towers.











Phone Consultation