Design Principles of Training Tower: Facilitate duty readiness, officer and soldier training, enhance the combat effectiveness of the team, and meet the needs of safeguarding modern construction and the safety of people's lives and property. Design Aim of Training Tower: Scientific and practical.
Fire training towers shall meet the following requirements:
One, the training tower should be located at the end of the training ground with a reserved runway, and a 1.5-meter sand pit should be reserved in front of the tower.
The training tower should have at least four floors, and in cities with a higher number of high-rise buildings, the number of floors can be appropriately increased.
Section 3: Each floor of the training tower's facade has at least two windows, with a width between the windows (and the wall) of 1.0 meter.
Four, the training tower window size is 1.2m x 1.8m, the window must be at least 0.65m from the tower edge, the window sill width is 0.4m, the sill board thickness is 0.05m (protruding from the tower wall by 5cm), the height of each window sill from the floor of that level is 0.8m, the level height is 3.5m, and an internal staircase with a clear width of at least 0.7m should be provided, with a handrail pipe diameter of at least 0.042m.
Five, An unobstructed platform of at least 1.5 meters wide should be set on the inside of each floor of the training tower, and a floor should be installed on the top level.
Six, it is advisable to install an outdoor fire escape ladder on the training tower. The ladder should lead to the top of the tower and ideally be set at a height of 3 meters from the ground, with a width not less than 60 centimeters. Training Tower Description: 1. Mainly composed of (1) simulated windows, (2) floor partitions, (3) rear frames, (4) observation and command platform frames, and the main steel structural frame. Simulated windows are installed at the front of the tower (customizable for the number of floors and windows as needed), with floor partitions (steel plates) between the upper and lower adjacent simulated windows. 2. A rear frame corresponding to the simulated windows is located below the rear of the tower. 3. The simulated windows, floor partitions, rear frames, and main frame are connected together with bolts. 4. There are safety ladders connecting between each floor. 5. The upper part of the tower is equipped with an observation and command platform.
Section 7: Training towers typically undergo anti-corrosion treatment with paint, in military green. Alternatively, camouflaged patterns or galvanized coatings are also available.
Section 8: Our steel structure fire training towers are fully functional, featuring detachable and portable designs with no limitations by region, terrain, or plot. They are constructed with assembled components, offering low cost and high recyclability, thereby saving expenses and achieving twice the results with half the effort. Welcome fire departments to order our fire training towers.