Product Details

(1) Product Name

Silicone rubber insulated heat-resistant soft cables

Standard of Execution

Q/12JH4065.1-2002

Application Scope

This product is suitable for high-temperature environments such as steel and smelting industries, with an alternating current rated voltage300-500V450-750V1140VVarious electrical equipment motor leads and connectors.

Utilize Features

1.Rated Voltage:U0/UPlease provide the Chinese content to be translated.300/500V450-750V1140V

2.Long-term allowable operating temperature for the cable conductor does not exceed180

3.The laying temperature of the cable should not be below-60

4.Recommended bend radius:

Flattened flexible cables should have a minimum bending radius not less than the cable's smaller side dimension.15Multiple.

Other cables should not be less than the outer diameter of the cable6Multiple.

Model

Cable model

Model

Name

Primary Application

JHXG

Silicone rubber insulated motor lead wires

H-level motor lead wire

YGZ

Silicone rubber insulated, silicone rubber sheathed medium heat-resistant flexible cables

For various mobile electrical appliances and tools

YGZB

Silicone rubber insulated silicone rubber jacket medium heat-resistant flat cable

For various portable electrical appliances and tools

YGC

Silicone rubber insulated silicone rubber sheathed heavy-duty heat-resistant flexible cable

For various portable electrical appliances, capable of withstanding considerable mechanical external forces

YGCB

Silicone rubber insulated silicone rubber sheath heavy-duty heat-resistant flat-shaped flexible cable

For various portable electrical appliances, capable of withstanding considerable mechanical external force


Cable specifications

Model

Rated Voltage

V

Core Count

Nominal Section

mm2

JHXG

1140

1

0.5-150

YGZ

300/500

2、3

4、5、6

4 (Three large, one small)

0.3-6

0.75-6

1.5-6

YGZB

300/500

2、3、4、5、6

0.75-6

YGC

450/750

1

2

3、4

5

4 (Three large and one small)

1.5-400

1.5-95

1.5-150

1.5-25

2.5-150

YGCB

450/750

2, 4, 4 (three large, one small)

3

5

1.5-120

1.5-150

1.5-70

 (II) Product Name

Fluoropolymers insulated high-temperature power cable

Standard of Execution

Q/12JH4066.1-2002

Application Scope

This product is suitable for fixed installation at rated voltageU0/UFor0.6/1KVWithin the transmission and distribution lines under high-temperature environments and below.

   Flame-retardant cables are primarily used in applications with high fire safety requirements. This product maintains all performance indicators of standard cables of the same voltage level and specifications, such as high mechanical and physical properties, excellent electrical performance, and resistance to chemical corrosion. Additionally, it features flame-retardant properties, preventing the spread of fires caused by cables and reducing significant losses of life and property.

   Low-smoke, halogen-free flame-retardant cables, in addition to maintaining the general characteristics and electrical properties of flame-retardant cables, also feature reduced smoke generation during combustion, minimal release of hydrogen chloride gas, and low corrosiveness.

Low-smoke, halogen-free flame-retardant products not only meet the requirements for flame-retardant cables but also feature minimal halogen acid gas release, low smoke generation, reduced corrosion, and excellent flame-retardant properties.

Utilize Features

1.Rated Voltage:U0/UFor0.6/1KV

2.Long-term allowable operating temperature for cable conductors:

FFType not exceeding200

ZR-FVZR-FV22Type not exceeding105

DL-FVWL-FVDL-FV22WL-FV22Type not exceeding90

3.The laying temperature of the cable should not be below0, below0Must be preheated prior to laying.

4.The bending radius of the cable should not be less than the outer diameter of the cable.15Multiple.

Model Name

Model

Name

FF

Fluorinated plastic insulated and sheathed high-temperature power cables

ZR-FV

Fluoroplastic insulated flame-retardant polyethylene sheathed high-temperature power cables

DL-FV

Fluoroplastic insulated low smoke low halogen flame-retardant polyvinyl chloride sheathed high temperature power cable

WL-FV

Fluorinated plastic insulated low-smoke halogen-free flame-retardant PVC sheathed high-temperature power cables

ZR-FV22

Fluoroplastic insulated flame-retardant polyvinyl chloride sheathed steel tape armored high-temperature power cable

DL-FV22

Fluoroplastic insulated low-smoke low-halogen flame-retardant PVC sheathed steel tape armored high-temperature power cable

WL-FV22

Fluoroplastic insulated, low-smoke, halogen-free flame-retardant PVC sheathed steel tape armored high-temperature power cables



Specification Structure

Model

Number of cores

Nominal Section Areamm2

FF

1~4,3+1

1.5~240

ZR-FV,DL-FV,WL-FV

1~4,3+1

1.5~185

ZR-FV22,DL-FV22, WL-FV22

2~4,3+1

4~185

(3) Product Name

Fluorinated plastic insulated silicone rubber sheathed high-temperature power cables

Execution Standards

Q/12JH4066.0-2002

Application Scope

This product features high-temperature and low-temperature resistance, softness, and corrosion resistance, and is suitable for industrial and mining enterprises in power generation, metallurgy, chemical industry, and petroleum industries.0.6/1KVFor connecting electrical power transmission lines to industrial mobile electrical equipment in harsh environments and below.

Utilize Features

1.Rated VoltageU0/UPlease provide the Chinese content to be translated.0.6/1KV

2.The long-term allowable operating temperature of the cable conductor does not exceed200

3.The laying temperature of the cable should not be lower than: Fixed laying-60

                           Non-permanent installation-20

4.Recommended bend radius:

Unarmored cables should not be less than the cable outer diameter of6Multiple;

The electrical cable should not be less than the cable's outer diameter by10Be;

Cables with armor structures should not be less than the outer diameter of the cable.12Multiple.

Cable Model and Name

Model

Name

Primary Application Scope

YGC-F46

Copper-core Fluoroplastic Insulated Silicone Rubber Sheathed High-Temperature Power Cable

Installed indoors, in cable trenches, and on pipe fixtures

YGC-F46-22

Copper-core Fluoroplastic Insulated Silicon Rubber Sheathed Steel Tape Armored High-Temperature Power Cable

Installed in indoor environments, cable trenches, pipelines, direct burial, and other fixed locations capable of withstanding significant mechanical external forces.

YGC- F46R

Copper-core Fluoroplastic Insulated Silicone Rubber Sheathed Flexible Core High-Temperature Power Cable

Installed for indoor applications requiring softness and mobility.


Cable specifications

Model

Core Count

Nominal Section Areamm2

YGC-F46

3-core, 3+1 core

4~240

YGC-F46-22
YGC- F46R

 (4) Product Name

Flat Soft Cable

Standard of Execution

Q/12JH4065.0-2002

Application Scope

This product is suitable for rated voltage0.6/1KVCranes, hoists, trolleys, boring machines, starting trailers, and other mobile equipment's power and lighting lines, and below.

Utilize Features

Rated VoltageU0/UFor0.6/1KV

Long-term allowable working temperature for cable conductors does not exceed70℃。

Cable laying temperature shall not be lower than-40℃。

The flexible flat cable should allow a bend radius not less than the size of the cable's smaller side.15Multiple.

Cable Model and Name

Model

Name

YVVB

Copper-core PVC-insulated PVC-jacketed flat flexible cable

YVFB

Copper-core PVC-insulated NBR-sheathed flat flexible cable

YFFB

Copper-core Nitrile Chlorinated Polyvinyl Chloride (PVC) Insulated and Sheathed Nitrile Chlorinated Polyvinyl Chloride Flat Flexible Cable

YFTVB

Copper-core Nitrile Chlorinated Polyethylene Insulating Elastomeric Chlorinated Polyethylene Sheathed Flat Flexible Cable

YVTVB

Copper-core Polyvinyl Chloride Insulated Elastic Sheath Flat Flexible Cable

YFGB

Copper-core Nitrile Chloroprene Insulated Silicone Sheath Flat Flexible Cable

YGFB

Copper-core silicone rubber insulated nitrile polyvinyl chloride sheathed flat flexible cable

YGTVB

Copper-core silicone rubber insulated elastomeric polyvinyl chloride sheathed flat flexible cable


Cable Specifications

Model

Core Count

Nominal Section Areamm2

YVVB

3-core

3+1 core

2.5~95

4~95

YVFB

YFFB

YFTVB

YVTVB

YFGB

YGFB

YGTVB

 (V) Product Name

Shielded power cable for variable frequency circuit

Execution Standards

Q/12JH4066.3-2002

Application Scope

This product is suitable for rated voltage0.6/1KVShielding requirements and strict power transmission lines, as well as power distribution lines, for systems compatible with variable-frequency motors. This product boasts excellent shielding capabilities, while also serving as a central neutral protective conductor.

Product Features and Usage Characteristics

1.Utilizes shielding that can resist static coupling, electromagnetic induction, radio waves, poor grounding, and interference from power cable conduction.

2.The shield layer (conductor within) utilizes a phase wire encapsulation. When zero sequence or high-order harmonic current components appear in the circuit, the total current within the shield layer (coaxial conductor) sums to zero, thereby not causing electromagnetic interference to the outside environment.

3.Low and uniform positive (reverse) and zero sequence impedance, it is beneficial to improve power supply quality when compared to the common four-core power cable.

4.The reactance value of the shielding layer (concentric conductor) under the zero-sequence operating condition is significantly lower than that of the fourth core conductor in a standard power cable, thus being advantageous for the application of new-type short-circuit automatic protection devices and ensuring the safe operation of the cable and other related equipment.

5.A certain proportion of the shielding layer and the main core cross-section of the cable.PEProtective function.

6.Double-layer composite shielding achieves an interference attenuation ratio of104Thus, ensure any external interference has no impact on the system.

7.Recommended Allowable Bend Radius: Cylinder for Cable Bend Test2Multiple.

8.Combustion characteristics

(1)      Bundle flame-retardant cables can withstandCB/T19380.3-BCategoryIEC332-3Regulated bundle combustion test.

(2)      Fire-resistant cables can withstandGB/T12666.6(IEC60331)Specified fire resistance test

Model

Cable Model and Name as shown in the table1Regulation

Model

Name

BPVVPP2PVC insulated and sheathed copper wire braided copper strip composite shielded variable frequency power cables
BPYJVPP2Cross-linked polyethylene insulated polyvinyl chloride sheathed copper wire braided copper strip wrapped composite shielded variable frequency power cable
BPVVFPP2PVC insulated nitrile PVC sheath copper wire braid copper strip wrapped composite shielded variable frequency power cable
BPYJVFPP2Cross-linked polyethylene insulated nitrile polyvinyl chloride sheathed copper wire braided copper strip wrapped composite shielded variable frequency power cable
ZR-BPVVPP2PVC insulated flame-retardant PVC sheathed copper wire braided copper strip composite shielded variable frequency power cable
ZR-BPYJVPP2Cross-linked polyethylene insulated flame-retardant polyvinyl chloride sheathed copper wire braided copper strip composite shielded variable frequency power cable
DL-BPVVPP2PVC insulated low-smoke, low-halogen flame-retardant PVC sheathed copper wire braided copper strip wrapped composite shielded variable frequency power cable
DL-BPYJVPP2Cross-linked polyethylene insulated low-smoke low-halogen flame-retardant polyvinyl chloride sheathed copper wire braided copper strip wrapped composite shielded variable frequency power cable
WL-BPVVPP2Chlorinated Polyvinyl Chloride (PVC) insulated low-smoke, halogen-free flame-retardant PVC sheathed wire braided steel tape wrapped composite shielded variable frequency power cable
WL-BPYJVPP2Cross-linked polyethylene insulated low-smoke halogen-free flame-retardant polyvinyl chloride copper wire braid copper strip wrapped composite sheathed variable frequency power cable
NH-BPVVPP2PVC insulated and sheathed copper wire braided copper strip wrapped composite shielded fire-resistant variable frequency power cable
NH-BPYJVPP2Cross-linked polyvinyl chloride insulated polyvinyl chloride sheathed copper wire braided copper strip wrapped composite shielded fire-resistant variable frequency power cable
BPFVPP2Fluoroplastic insulated polyvinyl chloride sheathed copper wire braided copper strip wrapped composite shielded variable frequency power cable
BPFFPP2Fluorinated plastic insulated fluorinated plastic sheathed copper wire braided copper strip wrapped composite shielded variable frequency power cable
BPFGPP2Fluoroplastic insulated silicone rubber jacket copper wire braided copper strip wrapped composite shielded variable frequency power cable
BPGGPP2Silicone rubber insulated silicone rubber jacket copper wire braided copper strip wrapped composite shielded variable frequency power cable
BPGVFPP2Silicone rubber insulated nitrile polyvinyl chloride sheathed copper wire braided copper strip wrapped composite shielded variable frequency power cable
ZR-BPFVPP2Fluoroplastic insulated flame-retardant PVC sheathed copper wire braided copper strip wrapped composite shielded variable frequency power cable
DL-BPFVPP2Fluorinated plastic insulated low-smoke low-halogen flame-retardant PVC sheathed copper wire braided copper strip wrapped composite shielded variable frequency power cable
WL-BPFVPP2Fluoroplastic insulated low-smoke halogen-free flame-retardant PVC sheathed copper wire braided copper strip wrapped composite shielded variable frequency power cable
NH-BPFVPP2Fluoroplastic insulated flame-retardant polyvinyl chloride sheathed copper wire braided copper strip wrapped composite shielded fire-resistant variable frequency power cable


Specs

Number of cores

Nominal Section Areamm2

2~4

1.5~240

3+1

3+3