High-voltage cross-linked cables_SupplyPro Co., Ltd._Tianjin Jincheng Wire & Cable Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》

High-voltage cross-linked cables

产品Price Negotiable

最小起订Quantity:1 piece 供货总Quantity: 9999 piece

用手机扫描二维码直达商品手机版
MobileView details
Location:
Tianjin
有效期至:
长期有效
最后更新:
2022-07-01 14:11
Product Details

(One)

Product Name

6~35KVCross-linked polyethylene insulated power cable

Product Standards

This product is manufactured in accordance with the GB/T12706 standard "Copper-core and Aluminum-core Power Cables with Plastic Insulation for Rated Voltage Up to and Including 35KV," and can also be produced according to customer requirements using international standards recommended by the IEC, British standards, German standards, and American standards.

Application Scope

This product is suitable for distribution and transmission lines with rated voltage of 3.6/6KV to 26/35KV, used for delivering electrical energy.

Utilize Features

Line Frequency Rated Voltage U0/U: 3.6/6 kV to 26/35 kV.

The allowable long-term high operating temperature for the cable conductor is 90°C.

During a short circuit (duration not exceeding 5 seconds), the high temperature of the cable conductor does not exceed 250°C.

The environmental temperature during cable laying should not be below 0°C.

Cable bend radius: Not less than 15 times the cable outer diameter for a three-core cable.

Single-core cable shall not be less than 20 times the diameter of the cable.

Cable model

Model

Name

Application Scope

YJV

Copper-core cross-linked polyethylene insulated PVC sheathed power cable

Indoor spaces, tunnels, and cable trenches cannot withstand mechanical external forces. Single-core cables are not permitted to be laid in magnetic pipelines.

YJLV

Aluminum-core Cross-linked Polyethylene Insulated PVC Sheathed Power Cable

YJY

Copper-core Cross-linked Polyethylene Insulated Polyethylene Sheathed Power Cable

YJLY

Aluminum-core Cross-linked Polyethylene Insulated and Polyethylene Sheathed Power Cable

YJV22

Copper-core cross-linked polyethylene insulated steel tape armored polyvinyl chloride sheathed power cable

Indoor, tunnel, cable trench, or buried installations, where it can withstand certain mechanical external forces but not significant tensile forces.

 

YJLV22

Aluminum-core cross-linked polyethylene insulated steel tape armored polyvinyl chloride sheathed power cable

YJV23

Copper-core Cross-linked Polyethylene Insulated Steel Tape Armored Polyethylene Sheathed Power Cable

YJLV23

Aluminum-core Cross-linked Polyethylene Insulated Steel Tape Armored Polyethylene Sheathed Power Cable

YJV32

YJV42

Copper-core cross-linked polyethylene insulated steel wire armored PVC sheathed power cable

Indoor, tunnel, cable trench, shaft, or underground installations, capable of withstanding mechanical external forces and certain tensile forces.

YJLV32

YJLV42

Aluminum-core Cross-linked Polyethylene Insulated Steel Wire Armored PVC Sheathed Power Cable

YJV33

YJV43

Copper-core cross-linked polyethylene insulated steel sheathed polyethylene jacket power cable

YJLV33

YJLV43

Aluminum-core cross-linked polyethylene insulated steel-armored polyethylene sheathed power cable

 

Production Range

Model

Core Count

Rated Voltage

3.6/6

6/6

6/10

8.7/10

8.7/15

12/20

18/20

18/30

21/35

26/35

Conductor Nominal Cross Section

YJV

YJLV

YJY

YJLY

1

25-1000

25-1000

25-1000

25-1000

25-1000

25-1000

25-1000

3

25-500

25-500

25-500

25-500

25-500

25-500

25-500

YJV22

YJLV22

YJV23

YJLV23

1

25-1000

25-1000

25-1000

25-1000

25-1000

25-1000

25-1000

3

25-500

25-500

25-500

25-500

25-500

25-500

25-500

YJV32

YJLV32

YJV33

YJLV33

1

25-1000

25-1000

25-1000

25-1000

25-1000

25-1000

25-1000

3

25-500

25-500

25-500

25-500

25-500

25-500

25-500

YJV42

YJLV42

YJV43

YJLV43

1

25-1000

25-1000

25-1000

25-1000

25-1000

25-1000

25-1000

3

25-500

25-500

25-500

25-500

25-500

25-500

25-500



(II)
 

Product Name

110~220KVHigh-voltage cross-linked cable

1.    Cross-linked polyethylene insulated corrugated aluminum sheath water-resistant sheath PVC jacket power cable

Model

YJLW02、YJLLW02

Specs

240mm2~3000mm2

Voltage

110~220KV

Usage

Suitable for humid environments or areas with low groundwater levels, it can be directly buried underground, installed in tunnels, or placed within pipelines.

 

2.    Cross-linked polyethylene insulated皱纹aluminum sheath waterproofing layer polyethylene sheath power cable

Model

YJLW03、YJLLW03

Specs

240mm2~3000mm2

Voltage

110~220KV

Usage

Ideal for areas with high groundwater levels, suitable for direct burial underground, within tunnels, or within pipelines. The cable can withstand significant tensile and pressure forces.


3.    Cross-linked polyethylene insulated lead sheathed polyvinyl chloride jacket power cable

Model

YJQ02、YJLQ02

Specs

240mm2~3000mm2

Voltage

110~220KV

Purpose

Suitable for areas with low groundwater levels, it can be directly buried underground, installed in tunnels, or placed within pipelines. The cable cannot withstand tension or pressure.


4.    Cross-linked polyethylene insulated lead sheathed polyethylene jacket power cable

Model

YJQ03、YJLQ03

Specs

240mm2~3000mm2

Voltage

110~220KV

Usage

Suited for areas with low groundwater levels, it can be directly buried underground, used in tunnels, or within pipelines. The cable cannot withstand tension or pressure.

 Utilize Features

The cable conductor is designed for a long-term working temperature of 90°C, with an emergency overload working temperature of 130°C.NoteDuring a short circuit (time ≤ 5 seconds), the conductor reaches a high temperature of 250°C.

   Note: There is no unified overload duration regulation for power departments in our country; the U.S. standard stipulates that when the load exceeds the rated load by 10%, the duration should not exceed 15 minutes.

The ambient temperature during cable installation should not be below -20°C, and the cable should be preheated during installation.

Cable minimum bend diameter:

Cable Type

Bent Diameter

Metal sleeve cable

After installation

30D0

Installation process

40D0

Note: D in the table0Actual outer diameter for cables.

Axial Allowable Tension Force During Cable Installation (not considering radial side pressure at turns)

T=K*Core Number * Section Area (kg)

Coefficient K value: 7 for copper cores, 4 for aluminum cores.

Permitted lateral pressure P during cable bending

Single-core cables require a P≤500 kg/m.

P=T/R(T represents the axial traction force, R stands for the bending wheel radius)

From the above equation, it is apparent that since traction is generally determined by cable length and weight, to ensure P meets the specified requirements, the diameter of the turning wheel should be increased.

Cable laying is not restricted by落差. 

Production Range

Model

Core Count

Cross-section

YJLW02

YJLLW02

1

240-2400

YJLW03

YJLLW03

YJQ02

YJLQ02

YJQ03

YJLQ03


询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

Phone Consultation

Consultation Phone:
0311-80808332

Back to Top