Steps for installing a louvered roof ventilator include determining the installation location, securing the base plate, adjusting the horizontal direction, fixing the pipe diameter and wheel head, installing the fan, and waterproofing treatment.
Confirm Installation Location: First, select a suitable spot for the louvre hood installation. The location should maximize the use of natural wind speed to effectively exhaust indoor heat.
Fixed Baseboard:Punch holes at designated positions using tools,then apply waterproof putty to the bonding panel.Secure the baseboard to the roof using screws.
Adjust horizontally: Use a level to align the horizontal orientation of the base plate, ensuring the wind cap operates effectively.
Fixed pipe diameter and wheel head: Secure the pipe diameter in place, then slide the wheel head into the groove, and fasten it with screws.
Install the fan: Secure the fan in place, ensuring all parts are firmly attached.
Waterproofing Treatment: Apply waterproof silicone around the perimeter of the substrate to prevent leakage during later use.


Additionally, note the following points:
The baffle hat relies mainly on natural wind speed to drive the fan, achieving the effect of indoor-outdoor air convection. Therefore, attention must be paid to its horizontal direction during installation to ensure the realization of the air convection effect.
The choice of installation location is also crucial; it should be reasonably set to utilize natural wind speeds for expelling indoor heat.
Before installation, it's essential to confirm that the dimensions match the installation location precisely.
During installation, waterproofing measures must be taken to prevent any leakage issues during later use.