Overview

Standard MicrocrystallineCOD Dissolver, featuring glass burr reflux tubes in place of spherical reflux tubes, and utilizing air-cooling technology instead of tap water cooling. The cooling section is mainly composed of a burr condenser tube and a fan. The upper part of the condenser tube is spherical, where the catalyst is added to prevent the instantaneous volatilization of light components in the sample. The lower part is burr-shaped, with three opposing spherical condenser tubes extending from the condenser tube wall on a single plane. Combined with the cooling water in the upper spherical reflux tube and the action of the internal fan, this ensures the sample's回流 cooling.

 

Key Features

Utilizing imported microcrystalline panels, resistant to700°C high temperature, even heat distribution, rapid heating/cooling, smooth and flat surface for easy cleaning and maintenance.

High-temperature-resistant ceramic fiber heating plate with a new designUniform thermal conductivity.

Glass burr回流管 and heat dissipation system, with excellent degassing回流 effect to ensure the parallelism and accuracy of the degassing results.

The digital display shows the temperature of the microcrystalline panel. The digital display indicates the dissolution time: temperature and timing can be set at any time.

After dissolution, the equipment automatically stops heating, while the fan continues to operate.120 minutes, auxiliary sample cooling, unattended operation possible.

 

Instrument structure

The instrument is mainly composed of the body, reflux tube, fan, and microcrystal heating plate.Comprising of 4 main parts, it utilizes microcomputer PID technology for timing control of the heating furnace plate and fan, allowing simultaneous heating of 8 cone-shaped flask reflux devices.

Chemical Solution Preparation and Operation of the InstrumentCOD calculations strictly comply with the (HJ828-2017) Chromic Acid Method. Water samples with COD levels below 50mg/L can enhance accuracy by diluting the titrant and oxidizing agents. For water samples with COD levels above 700mg/L, proportional dilution of the water sample is used to complete the measurement.

 

Technical Specifications

Measurement Range:10-1000 mg/L, and samples with concentrations greater than 1000 mg/L, diluted

Measurement Time:10 minutes to 2 hours

Measurement Error: Potassium Hydrogen Phthalate Standard Solution (500mg/L) Relative standard deviation not greater than 5.0%

Ambient Temperature:5-40°C, ≤85% non-condensing

Power Voltage:AC(220V±5%), 50Hz

Heating Power:2000W

Sample Quantity: 8 pieces (with 24# ground 250ml conical bottles)

Instrument dimensionsWide32.5 inches long, 44 inches wide, and 57 inches high.

 


Shipment List

Dissolver Main Unit

1 unit

Condenser

8 pieces

250 mL conical flask

8

Fuses

2 pieces

 