12kV Dry Type Composite Capacitive Wall Penetration Bushing_SupplyPro Co., Ltd._12kV Dry Type Composite Capacitive Wall Penetration Sleeve, Supply, Machinery Equipment Network_Baoding HeWei Power Technology Co., Ltd._Zhongshang 114 Industry Resources Network

Baoding HeWei Power Technology Co., Ltd.

Dry-type Composite Capacitive Through-Wall Bushings, Dry-type Composite Capac...

全国服务咨询热线:
15194798118  13730230676


12kV Dry Type Composite Capacitive Wall Penetration Bushing

价      格Negotiable

最小起订0 Piece库存0 Piece

Location
Hebei Baoding
有效期至
长期有效
最后更新
2023-03-04 11:12
View Count
46

Business Card

  • Your company's名称Baoding HeWei Power Technology Co., Ltd.
  • 联 系 人卢义京 (先生)
  • Your company'sPhone15194798118
  • Mobile号码13730230676
  • Company AddressHebei Province, Baoding City, Nankanzhuang Town Industrial Area

买家正在看

  • 40.5kV High-Voltage Wall Penetration Porcelain Insulator

    Negotiable

  • Dry-type composite insulated wall passing sleeve

    Negotiable

  • 126kV Dry-Type Composite Capacitive Through-Wall Bushing

    Negotiable

  • 24kV High-Voltage Wall Penetration Porcelain Tube

    Negotiable

Product Details

Product Introduction

This product is composed of main components such as the carrier fluid, capacitor core, outer sheath, skirt, flange, and end structure. A measuring tap is installed on the flange, which is opened for use during partial discharge and dielectric loss factor measurements. It should be reliably grounded during normal operation. The ends of the product feature equipment clamps.


Product Features

Dry-type composite capacitive insulation, oil-free, gas-free, and porcelain-free

·High soil resistance level

12kV干式复合电容型穿墙套管_看图王.png

Terms of Use:

·Ambient Temperature: -50℃ to +50℃

·Altitude: Product design is based on 1000m altitude; for altitudes above 1000m, adjustments are made according to GB 311.

· Filtration Grade: Outdoor IV/Indoor III (Special requirements, if any, to be noted)

Key Performance Indicators:

· Applicable rated voltage levels: 12kV, 24kV, 40.5kV, 72.5kV, 126kV, 252kV

Rated Single-Phase Current: ≤2500A

Insulation level and electrical performance:



· Temperature Rise: Not exceeding 85K

Electrical Testing:

60 Hz frequency withstand, partial discharge testing, dielectric loss, and capacitance

Operation and Maintenance:

Maintenance-free