Yiting Roof-Mounted Explosion-Proof Air Conditioner
Product Specifications
BZKT-55Ex Explosion-proof Rooftop Air Conditioner
Model: BZKT-55Ex
Brand: YingTeng
Cooling Capacity (KW): 55
Heating Capacity (KW): 65
Energy Regulation (%): 0/50/100
Airflow (m³/h): 10500
Static Pressure (Pa): 300
Temperature Range and Accuracy: 18-32℃ ±2℃
Power: 380V/50Hz, three-phase four-wire system
Rated Cooling/Heating Power (kw): 21.5/21
Compressor Type/Quantity: hermetically sealed scroll type/2
Evaporator and condenser type: copper tube with aluminum fin design
Blower Type/Power (KW): Double Inlet Centrifugal (Belt Drive)/3
Condenser Fan Type/Power (KW): Low-noise Axial/2x1.5
Air Filter: Panel-type Pre-Effective/G4
Electric Heating Power (KW): 18
Dimensions: Length 2365mm x Width 2200mmx1920
Weight (kg): 1350
Ex db eb ib mb lIB T4 Gb
Manufacturer: Henan Tongteng Explosion-Proof Electrical Equipment Co., Ltd.
The YingTeng explosion-proof air conditioner features the explosion-proof marking of Ex db eb ib mb lIB T4 Gb.
Note: The above technical specifications are for reference only, the actual product should be used as the standard.
1. Refrigeration nominal operating conditions: Indoor return air dry bulb temperature 27°C, wet bulb temperature 19°C; outdoor ambient air dry bulb temperature 35°C.
2. Heating nominal operating conditions: indoor return air dry bulb temperature 20°C, hot water inlet temperature 19°C; steam pressure 0.2 MPa.
3. The beauty method can be selected from electric heating, hot water heating, or steam heating; electric regulating valves are required for hot water and steam heating.
4. The ambient temperature during the unit's refrigeration operation must not be below 18°C; if a specific requirement is needed for ordering, please specify clearly.
5. Specifications and parameters are subject to change without prior notice due to product improvements or updates.
This product series complies with the following standards:
GB/T 3836.1-2021 "Explosive Atmospheres *1 Part: Equipment General Requirements"
GB/T 3836.2 - 2021 "Explosive Atmospheres *Part 2: Equipment protected by隔爆外壳 'd'"
GB/T 3836.3-2021 "Explosive Atmospheres *Part 3: Equipment protected by intrinsic safety 'i'"
GB/T 3836.4 - 2021 "Explosive Atmospheres - Part 4: Equipment protected by intrinsic safety 'i'"
GB/T 3836.9 - 2021 "Explosive Atmospheres *Part 9: Equipment protected by "m" type enclosures"
GB/T 3836.15-2017 "Explosive Atmospheres *Part 15: Design, Selection, and Installation of Electrical Equipment"
Explosion-proof air conditioners can operate normally under the following environmental conditions:
a) Altitude not exceeding 2,000m
b) Suitable for environments with temperatures ranging from -7℃ to 43℃, free of corrosive gases.
c) There are explosive hazard areas formed by mixtures of flammable gases, vapors, and air from Groups II A, II B, and T1 to T4.
The "Yingteng" explosion-proof air conditioning series models have been specially processed with explosion-proof technology, making them widely applicable in flammable and explosive areas in Zones 1 and 2. They are suitable for scientific research, oil, chemical, pharmaceutical, power plants, and other locations where IIA, IIB grade T1 to T4 combustible gases, steam, and air mixtures pose explosion hazards. Explosion-proof air conditioners are ideal for areas with temperature requirements. The Yingteng explosion-proof air conditioners have been inspected and certified by the National Explosion-Proof Electrical Product Quality Supervision and Inspection Center with explosion-proof certificates and CCC explosion-proof certificates. They feature an aesthetically pleasing design, reasonable structure, ease of installation and maintenance. The full range of explosion-proof air conditioners use brand-name compressors, microcomputer intelligent control, digital display, and offer low noise, stable performance, simple operation, and safety. They are highly favored by the market. (Customizable options include explosion-proof window-type air conditioners, explosion-proof duct-type air conditioners, explosion-proof ceiling-type air conditioners, explosion-proof fresh air air conditioners, explosion-proof marine air conditioners, explosion-proof corrosion-resistant air conditioners, explosion-proof high-temperature air conditioners, explosion-proof cold storage air conditioners, explosion-proof modular air conditioning units, and explosion-proof multi-split air conditioning units, etc.).
Roof-mounted explosion-proof air conditioning units are a full-air system designed for indoor air treatment, integrating cooling, heating, dehumidification, humidification, ventilation, and air purification functions into medium to large-scale air conditioning equipment. This product combines modular air handling units with direct expansion air conditioning technology, enabling centralized comprehensive control of cooling and air conditioning. It features high efficiency and energy saving, simple system, stable performance, compact structure, high control accuracy, safety and reliability, low noise, high static pressure, minimal vibration, high corrosion resistance, good sealing, excellent rain and dust protection, easy installation, and attractive appearance. The microcomputer control ensures the product's performance and quality are fully demonstrated and utilized.
The unit is divided into two sections: the compression and condensation section, and the air treatment section. The compression and condensation section is assembled in a modular manner, while the air treatment section is designed with modularization based on function. The casing is constructed with a cold-bridge-free aluminum alloy frame and a polyurethane sandwich panel with double-sided steel plates. The combination method of the unit is flexible and diverse, allowing for easy installation, and can be placed on rooftops or outdoor open spaces without the need for a dedicated machine room. The product is suitable for large industrial sites such as factories and workshops in areas with不便 access to water or water scarcity, as well as for full-air conditioning systems in comfort spaces like hospitals, malls, supermarkets, restaurants, and office buildings.
Roof-Type Explosion-Proof Air Conditioning Unit Product Features
1. Comprehensive Variety & Specifications: Rooftop air conditioning units are divided into three series based on function: Cold Air Type (L), Heat Pump Type (R), and恒温恒湿Type (H). The恒温恒湿Type is suitable for process air conditioning environments with high requirements for temperature and humidity, while the Cold Air Type and Heat Pump Type are ideal for comfort air conditioning spaces.
Products are customizable with cooling capacities ranging from 12kW to 490kW to meet the requirements of different high air volume and space air conditioning applications.
Products are categorized into standard, purification, and fresh air series based on applicable usage locations, and various functional sections can be optionally added for easy realization of multiple functions such as cooling, heating, dehumidification, humidification, air purification, noise reduction, and energy-efficient fresh air.
2. No dedicated machine room required, saving investment: The frame of this series of units is treated with anti-corrosion and waterproofing, allowing the entire unit to be placed on the roof or outdoor space, eliminating the need for a machine room and saving on building space and construction investment costs: The unit is a full air system, without a cooling water or chilled water system, thus saving on auxiliary equipment such as chilled water pumps, cooling water pumps, cooling towers, fan coils, and piping.
Investment preparation has reduced the construction cost. 3. Convenient transportation and easy installation: The unit design features two structural types: standard and purification models. The standard model is an integrated structure for cooling capacities under 140kW and a split structure for capacities above 140kW, facilitating transportation and installation. The purification model is modularly designed, allowing for the configuration of various functional sections as needed, featuring simple and versatile setup. The volume of each functional section
Compact, lightweight, and customizable according to on-site conditions; easy to transport and install. 4. Cold bridge-free frame, low air leakage rate: The air treatment sections use a cold bridge-free aluminum alloy frame, with panels made of polyurethane high-pressure foam insulated sandwich boards (outer panel: electrostatically coated steel plate, inner panel: galvanized steel plate). The frame and panels are equipped with special sealing insulating strips and a unique outdoor rainproof structure design, ensuring outdoor operation of the unit.
With required corrosion and rust resistance, vibrant colors, and elegant appearance. 5. The unit employs a renowned fully enclosed scroll compressor, ensuring smooth operation, reliable performance, and high refrigeration efficiency: Upon customer request, non-standard heat recovery units can also be provided for energy-saving and environmental protection.
6. Equipped with a direct-drive low-noise axial flow fan and a rear-tilt centrifugal blower, and featuring effective vibration isolation measures, ensuring the unit operates smoothly and reliably with low noise and minimal vibration.
7. Various refrigeration components and control devices are from internationally renowned brands, featuring high system reliability and stable performance.
8. Both evaporators and condensers are copper tube-aluminum fin heat exchangers, designed and optimized by computer, and manufactured on a dedicated heat exchanger production line, ensuring high efficiency and energy savings.
9. Standard units feature intelligent instrument control and can be optionally equipped with industrial-grade programmable logic controllers (PLCs) as per customer requirements. Purification units are standardly configured with PLC control, operating under optimized programs. They also have self-diagnosis and fault alarm functions. The controller is equipped with a standard RS485 communication interface, enabling remote control from a distance or connection to an intelligent control system for optimal equipment performance and reduced operation costs.
10. The air handling unit's return air can be in various types such as horizontal supply, side supply to the left and right of the unit, upward supply, and downward supply, which is particularly suitable for the retrofitting of air conditioning systems in old buildings (simply redirect the original return air ducts to the roof for connection to the main unit): Additionally, replacing the main unit that has reached its service life is also very convenient, eliminating any concerns for the users.
11. Units can be treated for explosion-proof and corrosion resistance according to specific application requirements. They are widely used in industries such as oil, chemical, metallurgy, and pharmaceuticals. The explosion-proof marking for the units is ExibeibibmbllBT4Gb. There are also products with the explosion-proof marking ExibeibibmbllcT4Gb. Please contact our technical department to confirm before placing an order.
Roof-Type Explosion-Proof Air Conditioning Unit Ordering Instructions
Users can select and combine various function segments based on their needs. When placing an order, it is recommended to provide a diagram illustrating the combination of function segments, and the following data should be provided: (No need for standard type units) 1. Cooling and heating requirements and heating method. Please note that the cooling capacity in the performance parameter table does not consider the change in heat dissipation caused by the change in the power of the supply fan due to the change in the external pressure of the unit.
2. Function section names, quantities; refer to Section 6, examples of function section combinations.
3. Provide excess pressure outside the machine
4. If there is a fresh air section, the user must provide the fresh air volume and operating conditions. Standard fresh air operating conditions are dry bulb temperature 35°C and wet bulb temperature 28°C.
5. Standard configuration includes a pleated non-woven fabric pre-filter and a bag-type non-woven fabric medium efficiency filter:
6. Aircraft Control Panel Arrangement: The control panel on the right side facing the airflow direction is referred to as right-hand, symbolized by 'Y'. The control panel on the left side is referred to as left-hand, symbolized by 'Z'. The definition of the control panel includes the maintenance door side, the system inlet and outlet pipes, the heat transfer medium inlet and outlet pipes, the condensate discharge side, and the operating side.
7. Are wind valves required, and what type (manual or electric) are they? If not specified, the product will not come with a wind valve.
8. Do you need a remote control box, and what is the desired length of the remote control cable?
9. Electric regulating valves must be selected for hot water and steam heating units.
10. The ambient temperature during the cooling operation of a single-cooling unit must not be below 18°C; please specify this requirement when placing an order.
Roof Type Explosion Proof Air Conditioning Unit Functional Segment Combination Description
The functional sections of the air treatment part offer various combinations, allowing users to flexibly select according to their actual needs.
b. Additional functional sections can be added or removed from the above air treatment section of the unit as needed.
c, The aircraft air handling section offers more functional segments for user selection, such as sound absorption sections, heat recovery sections, and ozone purification sections, etc.
d. Our explosion-proof rooftop air conditioning units are a featured product, suitable for use in flammable and explosive environments. For more details, please consult our technical department.
e. General type and basic function section unit performance parameters and exterior drawings are available in this sample. Performance parameters, static pressure outside the unit, etc., can be adjusted according to the actual needs of the user. For details, please consult our technical department.
f. There are various methods for returning air in the unit, such as top return, side return, and bottom return. The air supply also includes top supply, side supply, end supply, and bottom supply options: you can choose flexibly according to your needs, just specify in the order for the air supply and return method.