Product Introduction:
The ZF series vacuum pump station (also known as vacuum generator, vacuum station, negative pressure station, vacuum negative pressure station, etc.) is a complete system that uses one or two water ring vacuum pumps (or other types of vacuum pumps) as the vacuum acquisition equipment and a vacuum tank as the vacuum storage equipment. In situations where vacuum sources are frequently used but the required suction volume is small, this system significantly saves energy compared to using a vacuum pump directly and effectively extends the service life of the vacuum pump.
Product Application:
The equipment can provide vacuum sources for medical gas central stations in various large and medium-sized hospitals across China, and is widely used in vacuum stations of the chemical and pharmaceutical industries, filling systems in the light industry, vacuum forming of rubber and plastic components in the automotive industry, and flame-retardant conveyance systems for coal mines.
Vacuum sources for the banding and casting industries (V, V-EPC).
Structural Description:
One, after the initial startup, the entire operation of the device can be fully automated. During its operation, the vacuum level in the vacuum system fluctuates within the allowable range, and this range can be adjusted according to the user's requirements.
The device can be widely applied in various systems requiring vacuum, and it can also automatically control the system without human operation; it can automatically seal the vacuum system during power outages. Using this equipment will make your vacuum system more advanced, safe, and energy-efficient.
Three, this unit is equipped with an air-water separator (when the equipment is paired with a water ring vacuum pump), which can save water resources and reduce environmental pollution.
Operating Principle:
Firstly, set the upper and lower limits of the vacuum system (for example, the upper limit set to -0.08 MPa, and the lower limit set to -0.06 MPa). Once the system starts, one vacuum pump begins to operate until the vacuum level inside the vacuum vessel exceeds the set upper limit of -0.08 MPa. At this point, the vacuum pump automatically stops. The vacuum inside the vessel is then automatically sealed off by the check valve. If the vacuum level inside the vessel drops below the lower limit of -0.06 MPa due to operational needs, the other vacuum pump automatically starts, running until the vacuum level inside the vessel reaches the upper limit of -0.08 MPa. This cycle repeats automatically, maintaining the vacuum level inside the vessel between the upper and lower limits.
The two-pump vacuum pump can also be manufactured in a single-use with a backup configuration.