Beijing Xinjeton Technology Co., Ltd.VIP

热处理领域备件、马拉松氧探头、易普森氧探头、SSI氧探头、MESA探头
Enter Shop

Tianjin 1602900 Oxygen Probe Manufacturer SSI Oxygen Sensor Multi-purpose Furnace Charging Trays

平台认证
  • Unit Price

    Negotiable

  • Brand

    Beijing Xinjeton Technology Co., Ltd.

  • MOQ

    1Piece

Contact
Leave Msg

Platform Service

Supplier Verified



北京新捷顿科技有限公司

VIP   数字营销第1年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    Beijing Xinjeton Technology Co., Ltd.

  • Unit Price:

    Negotiable

  • MOQ:

    MOQ1Piece

  • Total:

    100Piece

  • Address:

    Beijing

  • Delivery:

    0Hours

  • View More

Description

Continuous furnace with 3 sections; atmosphere control measurement is placed in the last two sections.

The atmospheric measurement differences in the first section are too great (temperature and air are very unstable).

Oxygen probe installation and usage should be traceable, with records of replacement, installation dates, and oxygen probe serial numbers, etc., to be kept and preserved.

Installation Method: Lay flat or vertically, wire terminal temperature below 100°C, surrounding temperature below 50°C.

Oxygen probe outer diameter: 21mm, quick connection: 1-inch NPT.

Typically, a 11/2-inch (38mm) hole is drilled in the furnace body, and a 11/2-inch pipe threaded connector is welded. Use a 1-inch to 11/2-inch adapter for the oxygen probe. During installation, for safety, change the furnace atmosphere to nitrogen or install under a carbon-burning condition. Position: For horizontal installation, the oxygen probe should extend about 50-100mm from the wall, not exceeding 100mm to prevent bending damage. For vertical installation, it should be about 50mm above the effective heating area, and it is recommended to use an interval support sleeve to secure the spacing to prevent falling damage. Insertion speed: Initially, insert about 100mm in one go, followed by an insertion speed of 1-2 inches per minute. If removing a suspected problematic oxygen probe during high temperatures, do not exceed 2 inches per minute, and after removal, protect it with insulating material to prevent rapid cooling damage. Reference air: Clean air flow rate, 0.2-2.0 SCFH (standard cubic feet per hour), or 100-1000ml/min. The reference air pressure should not exceed 2psi, and it should take about 10 minutes or more after introducing the air to accurately measure. Note: Do not reverse the connection of reference air and carbon-burning air.

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery Beijing
Stock 100PieceMOQ1Piece
Brand Beijing Xinjeton Technology Co., Ltd.
Material crystal structure Other
Material Physical Properties Other
Material Ceramic
Expiry Long Valid
Update 2025-07-14 13:53
Gallery

Beijing Xinjeton Technology Co., Ltd.Published byTianjin 1602900 Oxygen Probe Manufacturer SSI Oxygen Sensor Multi-purpose Furnace Charging TraysGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top