The Ordos Chemical Industrial Park Water Storage Project in Inner Mongolia employs a two-bag-one-membrane impermeable structure. After the construction of the impermeable materials, an integrity test of the impermeable area was conducted using the electrical discharge testing method. Five leakage points were found during the inspection. On-site repairs were made to the geotextile leakage points, and a re-test confirmed the repairs were successful.