Micro-turbine pumps are used to achieve a closed-loop circulation of the reference gas, eliminating the clogging issues associated with traditional open-loop reference gas channels. The maintenance cycle is extended from once a week to once a quarter.
System Integration Compatibility
Multi-protocol communication interface: Supports Profibus-DP and EtheCAT industrial bus protocols, allowing direct connection to Ipson IPSEN® Pro systems or third-party PLCs with millisecond response times to meet real-time control requirements for continuous production lines. Carbon potential dynamic modeling: Integrates CO/CO2/H2O multi-atmosphere compensation algorithms, maintaining carbon potential calculation error less than ±0.07%C even with enrichment gas flow fluctuations of ±30%, particularly suitable for variable speed carburizing process control.