LRD-LWGYS Introduction

  •     The LRD-LWGYS series of turbine flowmeters integrates advanced technology from both domestic and international flow measurement instruments, optimized for simplicity, lightness, high precision, excellent reproducibility, and sensitive response. Installation and maintenance are straightforward.The next-generation turbine flowmeter, featuring ease of use and other advantages, is widely used for measuring liquids in closed pipes that are non-corrosive to stainless steel grades 1Cr18Ni9Ti and 2Cr13, as well as alumina Al2O3 and hard alloy, and are free of fibers and particles. The liquids should have a kinematic viscosity less than 5×10^-6 m²/s at working temperatures. For liquids with a kinematic viscosity greater than 5×10^-6 m²/s, the flowmeter can be used after real-liquid calibration. When paired with a display instrument with special functions, it can also perform quantitative control and overfill alarms, making it an ideal instrument for flow measurement and energy conservation.

  • LRD-LWGYS Product Features

  • High precision, typically up to ±1%R, ±0.5%R, with high-precision models reaching ±0.2%R.

  • Good repeatability, short-term repeatability can reach 0.05% to 0.2%. Due to its excellent repeatability, high precision can be achieved through regular calibration or online calibration.
    The flowmeter of choice for trade settlement.

  • Output pulse frequency signal, suitable for total quantity measurement and computer connection, no zero-point drift, strong anti-interference ability.

  • Achieve a high-frequency signal (3-4 kHz) with strong signal resolution.

  • Variety of sizes, medium to large diameters up to 1:20, small diameters at 1:10.

  • Compact and lightweight, easy to install and maintain, with high throughput capacity.

  • Suitable for high-pressure measurement; no need to drill holes on the instrument body, easy to manufacture high-pressure models.

  • Specialized sensors come in various types and can be custom-designed to meet specific user requirements, such as low-temperature models, bidirectional types, downhole models, and mixed-sand specialized sensors, among others.

  • Insertable design for large diameter measurements; minimal pressure loss; low price; non-stop flow extraction; easy installation and maintenance.

  • LRD-LWGYS Technical Specifications

  • Standard of Implementation

    Turbine Flow Sensor (JB/T9246-1999)

    Instrument Diameter (mm) & Connection Type

    4, 6, 10, 15, 20, 25, 32, 40, 50, 65, 80 sizes feature threaded connections

    Accuracy Grade

    ±1%R, ±0.5%R, ±0.2%R (Special Order)

    Range Ratio

     1:10;1:15;1:20

    Sensor Material

    304 stainless steel, 316 (L) stainless steel

    Terms of Use

    Medium Temperature: -20℃ to +120℃; Environmental Temperature: -20℃ to +60℃
    Relative humidity: 5% to 90%       Atmospheric pressure: 86Kpa to 106Kpa

    Signal Output Function

    Pulse Signal, 4-20mA Signal

    Communication Output Function

    RS-485 communication, HART protocol

    Work Power Supply


    Signal Line Interface

    Basic Type: Hausmann connector or with a 3-core cable; Explosion-proof Type: Internal thread M20*1.5

    Intrinsically Safe Rating

    Exia II CT4 or Exd IIB T6

    Protection Level

    IP65 or higher ( customizable )

    • External Power Supply: +24VDC ±15%, ripple ≤ ±5%, suitable for 4-20mA output, pulse output, RS485, etc.

    • Internal Power Supply: 1 set of 3.0V 10AH lithium battery, which can operate normally at battery voltages between 2.0V and 3.0V.


  • LRD-LWGYS Measuring Range and Working Pressure

  • Instrument Diameter

    (mm)

    Normal traffic range

    (m³/h)

    Expand traffic range

    (m³/h)

    Default installation method and pressure rating

    Optional installation methods and default pressure rating

    Specialized pressure rating

    (MPa)

    DN4

    0.04~0.25

    0.04~0.4

    Threaded installation, 6.3 MPa

    Flange installation, 2.5 MPa

    12、16、25

    DN6

    0.1~0.6

    0.06~0.6

    Threaded installation, 6.3 MPa

    Flange Installation, 2.5 MPa

    12、16、25

    DN10

    0.2~1.2

    0.15~1.5

    Threaded installation, 6.3 MPa

    Flange Installation, 2.5 MPa

    12、16、25

    DN15

    0.6~6

    0.4~8

    Threaded installation, 6.3 Mpa

    Flange Installation, 2.5 MPa

    4.0、6.3、12、16、25

    DN20

    0.8~8

    0.45~9

    Threaded installation, 6.3 MPa

    Flange Installation, 2.5 MPa

    4.0、6.3、12、16、25

    DN25

    1~10

    0.5~10

    Threaded installation, 6.3 MPa

    Flange Installation, 2.5 MPa

    4.0、6.3、12、16、25

    DN32

    1.5~15

    0.8~15

    Threaded installation, 6.3 MPa

    Flange Installation, 2.5 MPa

    4.0、6.3、12、16、25

    DN40

    2~20

    1~20

    Threaded installation, 6.3 MPa

    Flange installation, 2.5 MPa

    4.0、6.3、12、16、25

    DN50

    4~40

    2~40

    Flange Installation, 2.5 MPa

    Bolted connections, 6.3 MPa

    4.0、6.3、12、16、25

    DN65

    7~70

    4~70

    Flange Installation, 1.6 MPa

    Bolted connection, 6.3 MPa

    4.0、6.3、12、16、25

    DN80

    10~100

    5~100

    Flange Installation, 1.6 MPa

    Threaded connections, 6.3 MPa

    4.0、6.3、12、16、25

    DN100

    20~200

    10~200

    Flange Installation, 1.6 MPa


    4.0、6.3、12、16、25

    DN125

    25~250

    13~250

    Flange Installation, 1.6 MPa


    2.5、4.0、6.3、12、16

    DN150

    30~300

    15~300

    Flange Installation, 1.6 MPa


    2.5、4.0、6.3、12、16

    DN200

    80~800

    40~800

    Flange Installation, 1.6 MPa


    2.5、4.0、6.3、12、16

  • LRD-LWGYS Installation Dimensions


  • Sensor installation methods vary by specification, utilizing either threaded or flanged connections. Installation methods are depicted in Figures 1, 2, and 3, with installation dimensions listed in the table below:

  • Nominal Bore Diameter (mm)

    L(mm)

    G

    K(mm)

    D(mm)

    Number of Holes (n)

    4

    225

    G1/2




    6

    225

    G1/2

    10

    345

    G1/2

    15

    75

    G1

    Φ65

    Φ14

    4

    20

    80

    G1

    Φ75

    Φ14

    4

    25

    100

    G5/4

    Φ85

    Φ14

    4

    32

    140

    G2

    Φ100

    Φ14

    4

    40

    140

    G2

    Φ110

    Φ18

    4

    50

    150

    G5/2

    Φ125

    Φ18

    4

    65

    170


    Φ145

    Φ18

    4

    80

    200

    Φ160

    Φ18

    8

    100

    220

    Φ180

    Φ18

    8

    125

    250

    Φ210

    Φ18

    8

    150

    300

    Φ240

    Φ22

    8

    200

    360

    Φ295

    Φ22

    12

  • LRD-LWGYS Product Categories

  • Technical ItemsTechnical SpecificationsTechnical SpecificationsTechnical Specifications
    Instrument ModelLRD-LWGYS-NLRD-LWGYS-ALRD-LWGYS-BLRD-LWGYS-C
    Signal OutputPulse4-20mANo content provided.4-20mA/Pulse
    Power Supply+24VDC±15%+24VDC±15%24VDC±15%24VDC±15%Lithium-ion Battery24VDC±15%
    Precision Grade1.0-0.5 grades1.0 to 0.5 grade1.0-0.5 grades
    Measurement RangeStandard RangeStandard RangeStandard Range or Extended Range
    MonitorNo content provided.No content provided.Available
    Communication InterfaceN/ANo content provided.No content provided.Optional RS485
    Communication ProtocolN/ANo content provided.No content provided.Moubus HART
    Instrument MaterialStainless SteelStainless SteelStainless Steel
    Intrinsically Safe RatingN/AExdIIBT6 or ExiaIICT4ExdIIBT6 or ExiaIICT4
    Protection GradeIP60IP65IP65
    Total Power Consumption< 1W< 1W< 1W
    Instrument passageDN4~DN250DN4~DN250DN4~DN250
    Medium Temperature-20℃~120℃-20℃~120℃-20℃~120℃
    Ambient Temperature-30℃~60℃-30℃~60℃-30℃~60℃


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery JiangsuHuai'an
Brand Reldor
Company Name Jiangsu Ruida Instrument (Group) Co., Ltd.
Shipment Origin Jiangsu Huai'an
Contact Information 137-7043-4222
Expiry Long Valid
Update 2025-06-13 08:27
Gallery

Jiangsu Ruida Instrument (Group) Co., Ltd.Published byTurbine Flow MeterGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top