I. Terms of Use This product is suitable for single equipment matching in metallurgy, heavy industry, and mining machinery.Rare oil lubricationIn the system, the industrial lubricant with a viscosity grade of N22-N460 (equivalent to ISO VG22-460) is cooled using a shell and tube oil cooler. |
| Model | Nominal | Fuel Tank Volume m3 | Electric Motor | Filter Square footage m2 | Heat exchanger Area m2 | Cooling Water Pipe diameter mm | Cooling Water Consumption m3/h | Electric Heating Appliance power kW | Steam Pipe Bore size mm | Steam Consumption kg/h | Pressure Vessel Capacity m3 | Oil outlet Bore size mm | Return Oil Port Bore size mm | Weight (about) kg | |
| Extremum p | Power kW | ||||||||||||||
| XHZ-6.3 | 6.3 | 0.25 | 6 | 0.75 | 0.05 | 1.3 | 25 | 0.6 | 3 | — | — | — | 15 | 40 | 320 |
| XHZ-10 | 10 | ||||||||||||||
| XHZ-16 | 16 | 0.5 | 6 | 1.1 | 0.13 | 3 | 25 | 1.5 | 6 | — | — | — | 25 | 50 | 980 |
| XHZ-25 | 25 | ||||||||||||||
| XHZ-40 | 40 | 1.25 | 6 | 2.2 | 0.20 | 6 | 32 | 3.8 | 12 | — | — | — | 32 | 65 | 1520 |
XHZ-63 | 63 | ||||||||||||||
| XHZ-100 | 100 | 2.5 | 6 | 5.5 | 0.40 | 11 | 32 | 7.5 | 18 | — | — | — | 40 | 80 | 2850 |
| XHZ-125 | 125 | ||||||||||||||
| XHZ-160 | 160 | 5 | 4, 6 | 7.5 | 0.52 | 20 | 65 | 20 | — | 25 | 40 | — | 65 | 125 | 3950 |
| XHZ-200 | 200 | ||||||||||||||
| XHZ-225 | 225 | 10 | 4, 6 | 11 | 0.83 | 35 | 100 | 30 | — | 25 | 65 | — | 80 | 150 | 5660 |
| XHZ-315 | 315 | ||||||||||||||
| XHZ-400 | 400 | 16 | 4, 6 | 15 | 1.31 | 50 | 100 | 45 | — | 32 | 90 | — | 100 | 200 | 7290 |
| XHZ-500 | 500 | ||||||||||||||
| XHZ-630 | 630 | 20 | 6 | 18.5 | 1.31 | 60 | 100 | 55 | — | 32 | 120 | 2 | 100 | 250 | 8169 |
| XHZ-630A | 10160 | ||||||||||||||
| XHZ-800 | 800 | 25 | 6 | 22 | 2.2 | 80 | 125 | 70 | — | 40 | 140 | 2.5 | 125 | 250 | 11550 |
| XHZ-800A | 13780 | ||||||||||||||
| XHZ-1000 | 1000 | 31.5 | 6 | 30 | 2.2 | 100 | 125 | 90 | — | 50 | 180 | 3.15 | 125 | 300 | 13315 |
| XHZ-100A | 15500 | ||||||||||||||
| XHZ-1250 | 1250 | 40 | 6 | 37 | 3.3 | 120 | 150 | 110 | — | 50 | 200 | 4 | 150 | 300 | 15350 |
| XHZ-1250A | 17960 | ||||||||||||||
| XHZ-1600 | 1600 | 50 | 6 | 45 | 3.3 | 160 | 150 | 145 | — | 65 | 260 | 5 | 150 | 350 | 20010 |
| XHZ-1600A | 23020 | ||||||||||||||
| XHZ-2000 | 2000 | 63 | 8 | 55 | 6 | 200 | 200 | 180 | — | 65 | 310 | 6.3 | 200 | 400 | 25875 |
| XHZ-2000A | 30300 | ||||||||||||||
Note: 1. A is a pressure tank-based thin oil lubrication unit, arranged in a square configuration.
2. The helical gear oil pump is equipped with a 4-pole motor; the bevel gear oil pump is fitted with a 6-pole motor. The pole number is also determined by the medium viscosity; when the viscosity is high, a low-speed option is recommended.
3. If river water is used for cooling, it must be filtered and settled, with the water temperature not exceeding 32°C.