| Dust and mist cannon/Environmental protection mist cannon specifications | |||
| Model/Parameters | PY-10m | PY-30m | PY-40m |
| Pump Flow Rate | 35-45L/min | 35-45L/min | 35-45L/min |
| Work pressure | 2.5-4.5MPa | 2.5-4.5MPa | 2.5-4.5MPa |
| Horizontal Range | 10m | 20-30m | 30-38m |
| Control Method | Manual | Manual/Semi-Automatic/Fully Automatic | Manual/Semi-Automatic/Fully Automatic |
| Weight: kg | 80 | 200 | 250 |
| Pump | 3HP High-Pressure Three-Cylinder Plunger Pump | 3 kW High-Pressure Three-Cylinder Plunger Pump | 3HP High-Pressure Three-Cylinder Plunger Pump |
| Tilt angle | -10°,-60° | -10°,-60° | -10°,-60° |
| Rotational Angle | 360° (adjustable in both directions) | 360° (adjustable in both directions) | 360° (adjustable bidirectional) |
| Blower Motor | 3 kW high-speed motor | 4kw high-speed motor with dual fan blades | |
| Dimensions | 750mm*950mm*1475mm | 1260mm*1000mm*1900mm | 1260mm*1000mm*1900mm |
| Dust and Mist Spraying Machine / Environmental Protection Mist Spraying Machine Specifications | |||
| Model/Parameters | PY-60m | PY-80m | PY-100m |
| Pump Flow Rate | 35-45L/min | 120-160L/min | 120-160L/min |
| Work pressure | 2.5-4.5MPa | 2.5-5.5MPa | 2.5-5.5MPa |
| Horizontal Range | 50-60m | 70-80m | 90-100m |
| Control Method | Manual/Semi-Automatic/Fully Automatic | Remote/Full Automatic | Remote/semi-automatic |
| Weight: kg | 450 | 650 | 1050 |
| Pump | 5.5 kW High-Pressure Three-Cylinder Plunger Pump | 7.5 kW High-Pressure Three-Cylinder Plunger Pump | 11kw High-Pressure Three-Cylinder Plunger Pump |
| Tilt angle | -10°,-60° | -10°,-60° | -10°,-60° |
| Rotation Angle | 360° (adjustable bidirectional) | 360° (adjustable bidirectional) | 360° (adjustable in both directions) |
| Duct Motor | 11kw high-speed motor with dual blades | 22kw High-Speed Motor | 55kw High-Speed Motor |
| Dimensions | 1700mm*1200mm*2300mm | 1750mm*1200mm*2500mm | 2000mm*1500mm*2300mm |
Environmental Mist Sprayer Safety Operation Procedures and Precautions:
1. During operation, strictly adhere to the operational procedures. It is strictly prohibited to start the liquid pump first. The liquid pump must only be activated after the fog cannon's fan is running normally to prevent liquid from flowing back into the axial flow fan and nozzle due to the early start of the pump.
2. After the fan starts, personnel must not approach the intake of the axial flow fan or stand at the outlet of the wind tube. When spraying, the spray bucket should face outward; when there's wind, spray with the wind.
3. During spraying, the pressure must not exceed the maximum pressure of 40 kg as specified in the instruction manual.
4. Absolutely prohibit sand, mud, or debris from entering the water tank to prevent blockages in pipes, fog cannon nozzles, or damage to the plunger pump. In case of nozzle blockage or leakage, promptly shut off the spray valve or shut down the machine for cleaning and troubleshooting.
5. After the spraying operation, it is mandatory to drain all accumulated water from the machine, especially in areas with low temperatures prone to freezing. When not in use, ensure complete drainage to prevent equipment and pipeline cracking due to freezing. After operation, areas that may be splashed, such as hands, feet, and face, should be washed promptly.
6. Check the tightness of all screws, strictly prohibit the plunger pump from running empty without water to avoid damaging internal parts of the machine. During operation, it is strictly forbidden to touch any part of the body to the power-driven rotating or transmission components.
7. Do not operate the machine when the temperature reaches the freezing point or if there is ice inside, as it may cause the fog cannon to fail to rotate and damage the equipment or lead to other accidents. If operation is necessary, ensure the ice inside has melted before starting the machine.
8. Regularly check the oil and piston grease levels in the plunger pump, and top up promptly. During the freezing season, replace the diesel engine and plunger pump lubricants with antifreeze oil suitable for the local temperature and fuel.
Environmental fog cannons effectively reduce dust pollution and increase moisture in the air. In recent years, with the rapid development of industry, processes such as thermal power plants, crushing plants, selection plants, mines, metallurgical industries, and cement factories have produced a large amount of dust, exacerbating environmental pollution. This directly affects the quality of people's lives and even poses health risks and safety hazards. Traditional dust control methods are not only costly and ineffective but also prone to secondary pollution. The fog cannon's water mist dust removal is a cost-effective method for air pollution. The fog cannon water mist dust removal is a relatively new environmental biotechnology and is currently a promising dust removal technology.

The environmental-friendly fog cannon machine utilizes fogging dust-capturing technology that requires no ash cleaning. It consumes less dust removal water and has a reduced water output to be treated, preventing secondary pollution and thus improving the working conditions for staff. Simply supply water and compressed air to each dust-generating point, and the entire dust removal system can be easily controlled from a central control room, greatly facilitating dust removal management. The dust removal system occupies less space, saving effective space within the factory, reducing construction investment. Compared to conventional dust collectors, the fog cannon machine can save half of the energy consumption, significantly reducing dust removal operating costs, saving investment, having low installation costs, reliable dust-capturing performance, minimal maintenance, and low maintenance expenses.