| Dust Removal and Environmental Fog Spraying Machine Specifications | |||
| Model/Parameters | PY-10m | PY-30m | PY-40m |
| Pump Flow Rate | 35-45L/min | 35-45L/min | 35-45L/min |
| Work pressure | 2.5-4.5MPa | 2.5-4.5MPa | 2.5-4.5MPa |
| Horizontal Range | 10m | 20-30m | 30-38m |
| Control Method | Manual | Manual/Semi-Automatic/Fully Automatic | Manual/Semi-Automatic/Fully Automatic |
| Weight: kg | 80 | 200 | 250 |
| Pump | 3HP High-Pressure Three-Cylinder Plunger Pump | 3 kW High-Pressure Three-Cylinder Plunger Pump | 3 kW High-Pressure Three-Cylinder Plunger Pump |
| Tilt Angle | -10°,-60° | -10°,-60° | -10°,-60° |
| Rotational Angle | 360° (adjustable bidirectional) | 360° (adjustable in both directions) | 360° (adjustable bidirectional) |
| Blower Motor | 3kW high-speed motor | 4kW high-speed motor with dual blades | |
| Dimensions | 750mm*950mm*1475mm | 1260mm*1000mm*1900mm | 1260mm*1000mm*1900mm |
| Dust Removal Fog Cannon / Environmental Protection Fog Cannon Specifications | |||
| Model/Parameters | PY-60m | PY-80m | PY-100m |
| Pump Flow Rate | 35-45L/min | 120-160L/min | 120-160L/min |
| Work pressure | 2.5-4.5MPa | 2.5-5.5MPa | 2.5-5.5MPa |
| Horizontal Range | 50-60m | 70-80m | 90-100m |
| Control Method | Manual/Semi-Automatic/Fully Automatic | Remote/Full Automatic | Remote/semi-automatic |
| Weight: kg | 450 | 650 | 1050 |
| Pump | 5.5 kW High-Pressure Three-Cylinder Plunger Pump | 7.5 kW High-Pressure Three-Cylinder Plunger Pump | 11kw High-Pressure Three-Cylinder Plunger Pump |
| Tilt angle | -10°,-60° | -10°,-60° | -10°,-60° |
| Rotation Angle | 360° (adjustable in both directions) | 360° (adjustable in both directions) | 360° (adjustable in both directions) |
| Duct Motor | 11kw high-speed motor with dual blades | 22 kW high-speed motor | 55 kW high-speed motor |
| Dimensions | 1700mm*1200mm*2300mm | 1750mm*1200mm*2500mm | 2000mm*1500mm*2300mm |
The fog cannon is composed of components such as the impeller, air duct, rear diffuser, spray device, and bracket, featuring a new impeller, high-performance rear diffuser, and a new motor support structure. The fan efficiency is high, and the fog formation is stable with a wide range of fog volume adjustment. The droplet diameter is extremely uniform, operation is simple and convenient, and the service life is long. This machine is professionally designed by our company, incorporating advanced technologies from both home and abroad. It is an independently designed and developed new product with high quality and technological content, catering to the national environmental protection, dust removal, and disinfection needs. It is a new dust removal equipment designed to address PM2.5 air quality exceedances.

Dust Removal Fog Sprayer Operation, Maintenance, and Care
Please check that all connections are properly aligned and fasteners are secure before turning on the machine.
2. First, press the fan operation button on the control box with your finger (can be operated remotely). Once the fan starts and runs normally, press the spray start button and the pump head will begin to operate. Then, lower the pressure adjustment handle and adjust the pressure screw to maintain a pressure gauge reading of around 25-30kg. Tighten the fixed nut, release the water outlet switch connected to the air duct, and the air duct will start to spray, allowing you to proceed with the task. If the air duct needs to oscillate up and down or left and right (can be operated remotely), do so.
3. Upon completion of the task and when it's necessary to shut down, first press the spray stop button on the control box, then press the fan oscillation button and the fan stop button (can be operated remotely), and finally turn off the generator set.

4. Replace the engine oil in the pump head and crankcase every 20 hours, then every 50 hours thereafter. The appropriate time for an oil change is when the machine cools down after operation, simply unscrew the oil drain bolt on the pump head to release the oil and clear out any debris from the crankcase.
5. If you experience reduced flow and insufficient pressure during operation, please check if the pump's drive belt is loose, if the suction pipe is securely fastened and not leaking, and if the pump's piston seal is worn. Observe if any liquid flows back after closing the return valve; if it does, inspect the return valve stem or seat for damage. Any parts that cannot be repaired should be replaced immediately. Dealers provide free parts within the first year of factory warranty. Damage caused by non-compliance with operating procedures is not covered, but the factory or dealer is still obligated to provide service or repairs to the user.
App Description
1) City PM2.5 Air Pollution Control, Pollution and Dust Reduction, Urban Environmental Management
2) Dust control at the yard, spray fog for all coal piles, material piles, ash piles, and open-yard loading and unloading operations.
3) Dust control for construction sites, demolition projects, municipal infrastructure, construction waste, slag and waste materials, loading and unloading, stacking, and other activities that generate dust pollution.
4) Material transportation, including vehicles transporting dust-generating materials such as coal coking, sand and stone, earthwork, garbage, and sludge, as well as heavy vehicles, and dust pollution control during transportation due to material spillage or leakage.
5) Exposed ground dust. Implement greening projects. Effectively carry out dust suppression through green spraying measures.
6) Coal wharves, coastal port stockyards, bucket wheel operation, ore handling, bulk powder transportation, loading, transshipment, river channel improvement, dust pollution control in these areas, and port environmental management.
7) Truck unloading openings, dump truck dust control, and large cargo handling vehicle dust management
8) Disinfection services for airports, highways, stations, harbors, public places, and landfill sites; dust control, humidity maintenance, and temperature reduction for sports venues and hot areas.