Hebei Shenghe Fire Protection Equipment Co., Ltd.VIP

消防设备、电子产品、制冷设备、环保设备、水处理设备
Enter Shop

Compressed Air Foam Fire Extinguishing System

平台认证
  • Unit Price

    Negotiable

  • Brand

    Jiang He

  • MOQ

    1Tai

Contact
Leave Msg

Platform Service

Supplier Verified



河北圣河消防设备有限公司

VIP   数字营销第3年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    Jiang He

  • Unit Price:

    Negotiable

  • MOQ:

    MOQ1Tai

  • Total:

    1000Tai

  • Address:

    HebeiShijiazhuang

  • Delivery:

    0Hours

  • View More

Description

Foam Fire Extinguishing System

P-3%, 6% Type Protein Foam Fire Extinguisher: Protein foam fire extinguishing agent is a foaming liquid based on the hydrolyzed concentrated liquid of animal protein, containing appropriate stabilizers, preservatives, antifreeze, and other additives.

2. P-3%, 6% Type Protein Foam Fire Extinguishing Agent: This extinguishing agent is widely used in petrochemical companies, oil fields, oil depots, oil terminals, vessels, and fire departments. It can be mixed with water at a ratio of 3:97 to produce foam, and then further mixed to a ratio of 6:94 in various low expansion foam-producing equipment.

3. P-3%, 6% Type Protein Foam Fire Extinguisher: Primarily used to extinguish general non-aqueous (oil-based) flammable and combustible liquid fires, and also used for extinguishing fires of general solid materials. This extinguisher should be stored in a cool, dry, well-ventilated indoor environment with a temperature of -5℃ to 40℃, and has an effective shelf life of two to three years.

4. FP-3%, 6% Type Fluoroprotein Foam Fire Extinguisher: Fluoroprotein foam extinguisher is prepared by adding appropriate fluoro-carbon surfactant to protein foam extinguisher.

5. FP-3%, 6% Type Fluoroprotein Foam Fire Extinguishing Agent: Due to the action of fluoro-carbon surfactant, this extinguishing agent, in addition to the fire-suppressing properties of protein foam extinguishing agents, can also extinguish fires in large oil storage tanks using the "submerged jet" method. It can also be used in combination with dry powder extinguishing agents, with a fire-suppressing speed 33% faster than protein foam extinguishing agents.

6. FP-3%, 6% Type Fluoroprotein Foam Fire Extinguishing Agent: This product can be mixed with water at a ratio of 3:97 or 6:94 in various low expansion foam-producing equipment to produce foam, and is widely applicable in oil fields, oil depots, petrochemical enterprises, ships, airports, and units storing large quantities of oil products, for extinguishing large-scale oil fires.

7. FP-3%, 6% Type Fluoroprotein Foam Fire Extinguishing Agent: This extinguishing agent should be stored in a cool, dry, well-ventilated indoor environment with a temperature range of -5℃ to 40℃, and has a shelf life of two years.

8. AFFF-3%, 6% Type Water-Forming Foam Fire Extinguisher: This water-forming foam extinguisher is made by blending fluoro-surfactants, hydrocarbon surfactants, solubilizers, stabilizers, and other components with water, representing a new type of fire extinguishing agent.

9. AFFF-3%, 6% Type Water Film Foam Fire Extinguisher: Features include the ability to form a protective film over oil surfaces that prevents oil evaporation. With the combined action of the foam and protective film, it offers high and fast fire extinguishing efficiency, excellent flame retardant and sealing properties, and a long storage period.

10. AFFF-3%, 6% Type Water-Forming Foam Fire Extinguisher: This extinguisher is mixed with water in a ratio of 3:97 or 6:94 and can produce foam for extinguishing oil fires in various low and medium expansion foam-producing equipment.

11. AFFF-3%, 6% Type Water-Forming Foam Fire Extinguishing Agent: Can be used in conjunction with dry powder fire extinguishing agents for fire suppression, and can also be employed using the "submerged jet" method to extinguish fires in large oil storage tanks.

12. AFFF-3%, 6% Water Film Foam Fire Extinguisher: Widely used in oil fields, refineries, oil storage, ships, docks, airports, hangars, and more.

13. AFFF-3%, 6% Type Water Film Foam Fire Extinguisher: This extinguisher should be stored in a cool, dry, well-ventilated environment with a temperature range of -5~40°C, and has an effective shelf life of eight years.

14. S/AR-3%, 6% Type of Soluble Foam Fire Extinguishing Agent: Soluble foam fire extinguishing agent is composed of microbial polysaccharides, hydrocarbon surfactants, fluorocarbon surfactants, additives, preservatives, etc.

15. S/AR-3%, 6% Type Soluble Foam Fire Extinguisher: This extinguisher has good thixotropy and can be mixed with freshwater at a ratio of 3:97 or 6:94 in various low expansion foam generating equipment to produce foam.

16. S/AR-3%, 6% Type Soluble Foam Fire Extinguisher: Used for extinguishing fires caused by flammable polar solvents such as alcohols, fats, ethers, ketones, aldehydes, amines, and organic acids, and also suitable for extinguishing oil fires.

17. S/AR-3%, 6% Type Soluble Foam Fire Extinguisher: Widely applicable to large-scale chemical plants, chemical fiber factories, paint factories, solvent factories, alcohol factories, breweries, chemical product storage facilities, ships, and more.

18. S/AR-3%, 6% Type Soluble Foam Fire Extinguishing Agent: This extinguishing agent should be stored in a cool, dry, well-ventilated environment with a temperature range of -5℃ to 40℃, and has a shelf life of two years.

19. AFFF/AR-3%, 6% Soluble Water-Forming Foam Fire Extinguisher: This water-forming foam extinguisher is composed of hydrocarbon surfactants, fluorocarbon surfactants, alcohol-resistant agents, stabilizers, antifreeze agents, solubilizers, and polar film-forming agents, making it a multipurpose foam extinguisher.

19. S/AR-3%, 6% Type Firefighting Foam with Resistance to Solubility: This foam extinguisher, in addition to the general performance of water-based film-forming foam in extinguishing oil fires, also exhibits excellent capabilities in extinguishing fires caused by polar solvents such as alcohols, esters, ethers, ketones, and aldehydes. It has a long shelf life and can be mixed with water in a ratio of 3:97 or 6:94 in various low expansion foam-producing equipment for foam generation.

20. S/AR-3%, 6% Type Soluble Foam Fire Extinguishing Agent: Widely applicable to oil fields, refineries, oil depots, ships, large-scale chemical plants, chemical fiber factories, petrochemical enterprises, chemical product warehouses, solvent factories, etc.

21. The fire extinguisher should be stored in a cool, dry, well-ventilated environment with temperatures between -5°C to 40°C, and has a shelf life of two years.

22. FP/AR - 3%, 6% Type Fluoroprotein Alcohol-Resistant Foam Fire Extinguishing Agent: Fluoroprotein alcohol-resistant foam extinguishing agent is refined by adding appropriate alcohol-resistant agents, film-forming aids, hydrocarbon surfactants, and other additives to the fluoroprotein foam extinguishing agent.

FP/AR - 3%, 6% Type Fluoroprotein Antisoluble Foam Fire Extinguisher: It is a foam fire extinguisher that combines the functionality of fluoroprotein foam for extinguishing oil fires with the capability of antisoluble foam for extinguishing alcohol fires.

FP/AR --- 3%, 6% Type Fluoroprotein Antisoluble Foam Fire Extinguishing Agent: Can be mixed with fresh or seawater in a ratio of 3:97 or 6:94 in various low expansion foam-producing equipment to produce foam.

25. FP/AR---3%, 6% Type Fluoroprotein Antisoluble Foam Fire Extinguishing Agent: Suitable for extinguishing oil fires, as well as fires involving flammable polar solvents such as alcohols, ethers, ketones, and aldehydes.

26. FP/AR --- 3%, 6% Type Fluoroprotein Antisoluble Foam Fire Extinguishing Agent: Widely applicable to large-scale petrochemical enterprises, chemical fiber factories, oil depots, solvent factories, breweries, chemical product warehouses, ships, airports, oil drilling platforms, storage and transportation wharfs, with a validity period of two years.

27. Foam Cannon: The air foam cannon is a fire extinguishing cannon that produces and喷射 foam, used for extinguishing Class A, B, and C liquid fires from a distance, as well as for extinguishing solid material fires. It is suitable for petrochemical enterprises, storage areas, airports, warehouses, ports, and docks, and also for vessels, offshore fixed platforms, and fire trucks, among other facilities.

28. The main material of fixed fire hoses includes stainless steel, carbon steel, and aluminum alloy; they are available in two types based on the nozzle's horizontal and vertical angles: handle-type and wheel-type; the handle adjustment relies on the internal rotating mechanism of the cannon body.

29. The handwheel adjustment of fixed fire hose nozzles relies on the worm and worm gear mechanism inside the nozzle body; suitable for large space warehouses, museums, exhibition halls, archives, aircraft hangars, stadiums, conference rooms, studios, and ancient buildings.

30. Fixed fire hoses are suitable for harsh working environments such as dust, corrosive gases, high temperatures, and low temperatures; key locations in industries like petrochemicals, metallurgy, and electricity, such as oil storage areas, oil depots, oil terminals, high-temperature furnaces, cable trenches; fire trucks, fire boats, oil tankers, ports, and oil fields.

31. Foam Fire Extinguisher: An essential component of foam fire suppression systems, particularly suitable for areas handling flammable and combustible liquids on a large scale, where fire hazards are prevalent during production, storage, and use.

32. Foam Fire Extinguisher Working Principle: The foam extinguisher is mainly composed of flanges, cylinders, ball valves, internal joints, fire hoses, and end caps. It is distributed and installed at predetermined locations within the protected area. The flange is connected to the supply pipeline, with the ball valve closed and the end cap sealed during normal operation.

33. Foam Fire Extinguisher Working Principle: In the event of a fire, first unscrew the end cap, then attach the fire hose, and finally open the ball valve to deliver foam liquid to the foam generator. The foam fire extinguisher must be used within the specified pressure range.

34. High-multiplicity air foam generator: Capable of quickly mixing foam solution with air to form a large amount of foam, which rapidly covers the burning area, isolating it from air to achieve fire extinguishing.

35. High Multiplicity Air Foam Generator: The high multiplicity foam uses less water, resulting in minimal water damage. It effectively removes smoke and toxic gases, suitable for full or partial flooding in confined spaces. Used in aircraft hangars, car parks, oil depots, mines, liquefied petroleum gas stations, oil terminals, libraries, archives, and more.

36. Low-Expansion Air Foam Generator: A device that mixes foam concentrate from a proportioning system with inhaled air to produce foam, which is then sprayed onto the surface of the burning liquid to form a foam layer. This layer isolates air, absorbs heat, and thus extinguishes the fire. Generally used for extinguishing Class A and B fires, primarily for oil fires.

37. Medium Expansion Air Foam Generator: Comprised primarily of nozzles, foaming mats, and foam chambers, this equipment generates and喷射s medium expansion foam. It can be paired with foam fire trucks, water tank fire trucks, and portable fire pumps with pipeline type proportioning mixers to utilize medium or high expansion foam extinguishing agents to produce medium expansion foam.

38. Medium Multiple Air Foam Generator: Suitable for extinguishing oil product fires and solid material fires. Widely applicable in small and medium-sized warehouses, coal mines, chemical production workshops, ships, garages, and aircraft hangars.

39. Portable Foam Fire Extinguisher Cart: The portable foam fire extinguisher cart is mainly composed of a normal pressure foam liquid storage tank, foam lance, pipeline-type proportioning mixer, firehose, and a cart frame. It can be used by connecting the firehose provided with the device to fire hydrants and other water supply equipment. It can be placed in a favorable location for extinguishing fires.

40. Mobile Pushcart Foam Fire Extinguishing Equipment: As a supplement to fixed fire extinguishing equipment, it is used for fire protection of multiple devices within the protected area. Suitable types of foam liquid can be selected as needed for extinguishing various types of liquid fires. The mobile pushcart foam fire extinguishing equipment is widely used in residential areas, industrial and mining enterprises, oil depots, chemical departments, heat treatment workshops, gas stations, and other locations.

41. Mobile Push Cart Foam Fire Extinguishing Device Operation Principle: When fire extinguishing is required, connect the foam gun and proportioning mixer with a fire hose. Connect the fire hose to the inlet of the proportioning mixer and introduce pressurized water. As the pressurized water flows at a high speed through the nozzle of the proportioning mixer, a negative pressure is formed inside the mixer. Under the action of atmospheric pressure, foam liquid from the foam liquid storage tank enters the proportioning mixer through the suction pipe. It is mixed with the pressurized water in a predetermined ratio to form a foam mixture. When the foam mixture, at a certain pressure, passes through the foam gun, it draws in air, causing the mixture to foam and spray over the burning liquid surface, extinguishing the fire.

42. Pressure-Driven Foam Ratio Mixing Unit (Vertical): It consists of a foam liquid storage tank, capsules, pressure ratio mixer, safety valve, control valve, and some auxiliary components. When the fire suppression water pressure flows through this equipment, the ratio mixer diverts it proportionally. A small portion of the water enters the interlayer of the foam liquid storage tank equipped with capsules, squeezing the capsules. The displaced foam liquid mixes with the fire water in the main pipeline to form a foam mixture of a specific ratio, which is then supplied to the foam generating equipment.

43. Pressure-Driven Foam Ratio Mixing Unit (Vertical Type): Offers the advantages of space-saving and favorable for zoning protection, suitable for foam systems with multiple fire divisions and a requirement for minimal foam tank space occupation. It is more space-saving on the ground for foam tanks with the same foam liquid capacity.

44. Pressure-actuated Foam Ratio Mixing Device (Vertical Type): Suitable for mixing ratios of 3% or 6% foam fluids, this device is widely used in oil storage tank areas, chemical factories, aircraft hangars, oil fields, fuel power plants, boiler rooms, underground parking garages, hazardous material warehouses, and chemical product warehouses, as well as in water spray---foam interconnection systems.

45. Pressure-Driven Foam Ratio Mixing Unit (Horizontal Type): It consists of a foam liquid storage tank, capsules, pressure ratio mixer, safety valve, control valve, and some auxiliary components. When fire-fighting water pressure flows through this equipment, the ratio mixer diverts it proportionally. A small portion of the water enters the interlayer of the foam liquid storage tank with capsules, squeezes the capsules, and the displaced foam liquid mixes with the remaining fire-fighting water in the main pipeline to form a foam mixture of a specific ratio, which is then supplied to the foam-producing equipment.

46. Pressure-Driven Foam Ratio Mixing Unit (Horizontal Type): Suitable for mixing foam fluids at ratios of 3% or 6%, this unit is widely used in oil storage tank areas, chemical factories, aircraft hangars, oil fields, fuel power plants, boiler rooms, underground parking garages, hazardous material warehouses, and chemical product warehouses, as well as in water spray systems integrated with foam systems.

47. Balanced Ratio Foam Mixing Device: In foam fire suppression systems, large-scale foam fire protection projects place higher demands on the supply source of foam mixture. The limited foam liquid supply of traditional pressure tank foam ratio mixing devices is increasingly inadequate to meet the requirements of modern large-scale foam fire protection projects.

48. Balanced Ratio Foam Mixing Unit: This is a new type of foam fire extinguishing device that supplies foam concentrate to foam fire protection systems, primarily used for medium to large-scale foam fire protection systems in places such as petrochemical industries, ports, oil depots, airports (warehouses), and offshore platforms.

49. Balanced Foam Ratio Mixing System Advantages: Utilizes atmospheric pressure, bagless, stainless steel (fiberglass) foam liquid storage tanks, eliminating losses due to capsule damage and high pressure vessel manufacturing costs.

50. Balanced Foam Ratio Mixing Unit Advantages: The unit is applicable to any foam extinguishing agent, including protein foam, fluoroprotein foam, and aqueous film-forming foam.

51. Balanced Foam Ratio Mixing Unit Advantages: The foam liquid can be added during the extinguishing process of the unit, particularly suitable for medium to large-scale foam fire protection projects. The dynamic adjustment of the balance valve ensures the mixing ratio.

52. Balanced Foam Ratio Mixing Device Advantages: The supply method of the foam pump injecting foam liquid allows for a wide range of working pressure and flow rates in the foam mixture. Operation is simple and more conducive to automation control.

53. Foam fire suppression systems emit a visible water mist during operation, which can reduce smoke content and toxicity at the scene, benefiting the evacuation of personnel and firefighting efforts. They primarily come in two types: portable, hand-held foam extinguishers and trolley-mounted foam extinguishers, as well as air foam extinguishers. Each type of extinguisher is suited for different types of fires.

54. Foam Fire Extinguishing Systems: 1. Portable foam extinguishers are suitable for extinguishing Class B fires, such as those involving oil products and greases, and can also be used for Class A fires. However, they are not effective against fires involving water-soluble, flammable, or combustible liquids like alcohols, esters, ethers, and ketones; nor can they extinguish fires involving electrical equipment or Class C and D fires. 2. Wheeled foam extinguishers are suitable for Class B fires, including those involving oil products and greases, and can also be used for Class A and F fires. They are not effective against Class C, D, and E fires. 3. Air foam extinguishers are primarily used for initial fires involving flammable liquids such as gasoline, kerosene, diesel, vegetable oils, and greases. They can also be used for initial fires involving flammable solids like wood, cotton, and paper.

55. Pressure-Proportioning Mixing Device: The pressure-proportioning mixing device consists of two parts: a foam liquid pressure storage tank and a foam proportioning mixer. It is an equipment for storing foam liquid and mixing foam liquid with water in a fixed proportion. Features: 1. The system does not require a separate foam liquid pump; it can directly use fire hydrant pressure water to drive the foam liquid, saving equipment costs. 2. The mixing ratio is accurate and stable, ensuring the proper foam-to-water ratio for fire extinguishing, making the extinguishing process quick and reliable. 3. Low pressure loss ensures the necessary pressure for foam-producing equipment at the system's end. 4. Foam liquid and water are isolated by capsules, preventing the foam liquid from degrading after single use, making it easy to use, adjust, and conduct routine tests. 5. Easy to operate and maintain with a small footprint, suitable for automatic control. 6. Available in various capacities of foam liquid storage tanks and different flow ratio mixers, catering to the needs of various foam-producing equipment. 7. Widely applicable in low, medium, and high expansion foam fire extinguishing systems.

56. Foam fire suppression systems are classified by structure into fixed, semi-fixed, and portable types. A semi-fixed system refers to a fire suppression system composed of a fixed foam generator and partially connected pipes, a foam fire truck, or a mobile pump, connected with hoses.

57. A foam mobile system refers to a fire suppression system composed of fire trucks, mobile fire pumps, or pressurized water sources, foam proportioning mixers, foam nozzles, foam cannons, or mobile foam generators, connected with hoses and other equipment.

58. Foam Fire Extinguishing System: Benefits include the foam being less susceptible to oil contamination on the liquid surface, and the use of inexpensive ordinary protein foam. It comes in three application forms: fixed, semi-fixed, and portable. Submerged liquid systems are typically designed as fixed or semi-fixed.

59. Foam Fire Extinguishing System: For water-soluble liquid fires, it is mandatory to use a fire-fighting foam that is resistant to solubility. When extinguishing water-soluble liquid fires, liquid-over or semi-liquid-under jet foam should be used; liquid-under jet foam should not be employed.

60. Foam Fire Extinguishing System: For non-aqueous liquid fires, protein, fluoroprotein, film-forming fluoroprotein, or aqueous film-forming foam can be used for overhead foam extinguishing.

61. Foam Fire Extinguishing System: When using submersible jet foam fire extinguishing, it is mandatory to select fluoroprotein, film-forming fluoroprotein, or water-forming foam liquid. The storage temperature of the foam liquid should be between 0°C to 40°C.

62. Foam Fire Extinguishing Systems: Divided into low expansion, medium expansion, and high expansion foam extinguishing systems. Low expansion foam extinguishing systems are suitable for extinguishing systems in places such as Class A, B, and C liquid storage tanks, as well as petrochemical facilities.

63. Foam Fire Extinguishing Systems: Categorized by system form: flooding systems, local application systems, mobile systems, foam-water sprinkler systems, and foam spray systems.

64. Foam Fire Extinguishing System: Low expansion foam extinguishing systems are suitable for fixed-roof storage tanks containing non-water-soluble liquids. They are not suitable for water-soluble liquids and fixed-roof storage tanks containing Class A, B, or C liquids that are destructive to ordinary foam, nor are they suitable for external floating roof or internal floating roof tanks.

65. Low-Expansion Foam Fire Extinguishing Systems: Foam guns are suitable for: 1) Non-aqueous liquid fixed-roof storage tanks with diameters less than 18 meters. 2) Fire outbreaks of Class A, B, and C liquids within embankments. 3) Stack platforms for Class A, B, and C liquid tanker trucks or rail tank cars. 4) Outdoor fire outbreaks of Class A, B, and C liquids. 5) Aircraft hangars.

66. Medium Multiplicity Foam Fire Extinguishing System: Local Application Systems: A Class fire locations with incomplete enclosure on all sides, scattered B Class fire locations at designated positions, and flowing B Class fire locations with fixed positions not exceeding 100㎡ in area.

67. High-Expansion Foam Fire Extinguishing System: Local Application System - Suitable for Class A fire areas with partially enclosed perimeters, also applicable to the pooling or containment area of liquidation stations and receiving stations.

68. High-expansion foam fire suppression system: Portable systems; locations where the fire source is difficult to determine or personnel cannot access, flowing B-class fire areas, enclosed spaces that require smoke extraction, cooling, or removal of harmful gases during a fire.

69. Foam Fire Extinguishing System: Selection and Installation Requirements for Foam Fire Pumps and Foam Mixing Pumps: Foam fire pumps and foam mixing pumps should be selected with a flat characteristic curve centrifugal pump, and their working pressure and flow rate should meet the system design requirements. When using a hydraulically driven balanced proportioning mixing device, the water flow rate consumed should be included in the rated flow of the foam fire pump. When using a recirculating pump type proportioning mixer, the rated flow of the foam mixing pump should be 1.1 times the system design flow. A vacuum pressure gauge or vacuum gauge should be installed on the pump inlet pipe; a pressure gauge, check valve, and a return pipe with a control valve should be installed on the pump outlet pipe.

70. Foam Fire Extinguishing System: The selection and setup requirements for foam liquid pumps: The working pressure and flow rate of the foam liquid pump should meet the system design requirements and match the working pressure and flow rate range of the selected proportioning device. It should also ensure that the foam liquid supply pressure is greater than the water pressure at the design flow rate; the structural form, sealing, or filling type of the foam liquid pump should be suitable for transporting the selected foam liquid, and its material should be resistant to foam liquid corrosion without affecting the performance of the foam liquid; a standby pump should be equipped, with the specifications and models of the standby pump identical to the working pump, allowing for automatic or manual switching to the standby pump in case of a working pump failure; the foam liquid pump should withstand at least 10 minutes of no-load operation; except for hydraulic-driven pumps, a power source should be set.



Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery HebeiShijiazhuang
Stock 1000TaiMOQ1Tai
Brand Jiang He
Is Importing No
Usage Fire Extinguisher
Is the supply cross-border? No
Expiry Long Valid
Update 2024-07-17 14:38
Gallery

Hebei Shenghe Fire Protection Equipment Co., Ltd.Published byCompressed Air Foam Fire Extinguishing SystemGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top