Hebei Shenghe Fire Protection Equipment Co., Ltd.VIP

消防设备、电子产品、制冷设备、环保设备、水处理设备
Enter Shop

Foam Fire Extinguisher

平台认证
  • Unit Price

    Negotiable

  • Brand

    Jianghe

  • MOQ

    1Individual

Contact
Leave Msg

Platform Service

Supplier Verified



河北圣河消防设备有限公司

VIP   数字营销第3年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    Jianghe

  • Unit Price:

    Negotiable

  • MOQ:

    MOQ1Individual

  • Total:

    1000Individual

  • Address:

    HebeiShijiazhuang

  • Delivery:

    3days

  • View More

Description

Foam Fire Extinguishing System

P-3%, 6% Type Protein Foam Fire Extinguishing Agent: Protein foam fire extinguishing agent is a foaming liquid based on the hydrolyzed and concentrated liquid of animal protein, and contains appropriate stabilizers, preservatives, antifreeze, and other additives.

2. P-3%, 6% Protein Foam Fire Extinguisher: Widely used in petrochemical companies, oil fields, oil depots, oil loading terminals, vessels, and fire brigades, this extinguisher can be mixed with water in a 3:97 ratio to produce foam at a 6:94 ratio in various low expansion foam-producing equipment.

3. P-3% & 6% Protein Foam Fire Extinguisher: Primarily used to extinguish general non-aqueous (oily) flammable and combustible liquid fires, and also for fires involving general solid materials. This extinguisher should be stored in a cool, dry, well-ventilated room with a temperature of -5℃ to 40℃, and has a shelf life of two to three years.

4. FP-3%, 6% Type Fluoroprotein Foam Fire Extinguishing Agent: Fluoroprotein foam fire extinguishing agent is made by adding appropriate fluorochemical surfactants to protein foam fire extinguishing agent.

5. FP-3%, 6% Type Fluoroprotein Foam Fire Extinguishing Agent: Due to the action of fluorochemical surfactants, this extinguishing agent not only has the fire-suppressing properties of protein foam extinguishers but also can be used for extinguishing fires in large oil storage tanks with the "submerged jet" method. It can also be used in combination with dry powder extinguishing agents, achieving a faster extinguishing speed, 33% faster than protein foam extinguishers.

6. FP-3%, 6% Fluoroprotein Foam Fire Extinguishing Agent: This product can be mixed with water at a ratio of 3:97 or 6:94 in various low expansion foam-producing equipment to generate foam, and is widely applicable in oil fields, oil depots, petrochemical enterprises, ships, airports, and units storing large quantities of oil products. It is used to extinguish large-scale oil fires.

7. FP-3%, 6% Type Fluoroprotein Foam Fire Extinguishing Agent: This extinguishing agent should be stored in a cool, dry, well-ventilated indoor environment with a temperature range of -5℃ to 40℃, and has a shelf life of two years.

8. AFFF-3%, 6% Type Water Film Foam Fire Extinguisher: This water film foam fire extinguisher is made by mixing a multi-component mixture of fluoro-surfactants, hydrocarbon surfactants, solubilizers, stabilizers, etc., with water, and is a new type of fire extinguisher.

9. AFFF-3%, 6% Type Water Film Foam Fire Extinguisher: Features include the ability to form a protective film over oil surfaces that prevents oil evaporation. With the combined action of foam and the protective film, it offers high fire extinguishing efficiency, rapid response, excellent anti-reburning and sealing properties, and a long storage period.

10. AFFF-3%, 6% Type Water-Forming Foam Fire Extinguisher: Mixed at a ratio of 3:97 or 6:94 with water, this extinguisher can foam up in various low to medium expansion foam-producing equipment to extinguish oil fires.

11. AFFF-3%, 6% Film Forming Foam Fire Extinguisher: Can be used in conjunction with dry chemical fire extinguishers for fire suppression, and can also be employed using the "submerged jet" method to extinguish fires in large oil storage tanks.

12. AFFF-3%, 6% Film Forming Foam Fire Extinguisher: Widely used in oil fields, refineries, oil storage facilities, ships, docks, airports, hangars, and more.

13. AFFF-3%, 6% Film Forming Foam Fire Extinguisher: This extinguisher should be stored in a cool, dry, well-ventilated environment with a temperature range of -5~40°C, and has an effective shelf life of eight years.

14. S/AR-3%, 6% Type of Antisolvent Foam Fire Extinguishing Agent: The antisolvent foam fire extinguishing agent is composed of microbial polysaccharides, hydrocarbon surfactants, fluorochemical surfactants, additives, preservatives, etc.

15. S/AR-3%, 6% Type Soluble Foam Fire Extinguisher: This extinguisher has good thixotropy and can be mixed with freshwater at a ratio of 3:97 or 6:94 in various low expansion foam generating equipment to produce foam.

16. S/AR-3%, 6% Type Flame Retardant Foam: Used for extinguishing fires caused by flammable polar solvents such as alcohols, fats, ethers, ketones, aldehydes, amines, organic acids, etc., and can also be used for extinguishing oil fires.

17. S/AR-3%, 6% Type Soluble Foam Fire Extinguisher: Widely applicable in large chemical plants, chemical fiber factories, paint factories, solvent factories, alcohol factories, breweries, storage of chemical products, ships, etc.

18. S/AR-3%, 6% Type Soluble Foam Fire Extinguisher: This extinguisher should be stored in a cool, dry, well-ventilated environment with a temperature range of -5℃ to 40℃, and has a shelf life of two years.

19. AFFF/AR-3%, 6% Soluble Water-Forming Foam Fire Extinguisher: This water-forming foam fire extinguisher is composed of hydrocarbon surfactants, fluorocarbon surfactants, alcohol-resistant agents, stabilizers, antifreeze agents, solubilizers, and polar film-forming agents, making it a multipurpose foam fire extinguisher.

19. S/AR-3%, 6% Type Soluble Foam Fire Extinguisher: This extinguisher, in addition to the general performance of water-forming foam fire extinguishers in extinguishing oil fires, also excels in extinguishing fires caused by polar solvents such as alcohols, esters, ethers, ketones, and aldehydes. It has a long storage period and can be mixed with water at a ratio of 3:97 or 6:94 in various low expansion foam-producing equipment to produce foam.

20. S/AR-3%, 6% Type Soluble Foam Fire Extinguisher: Widely applicable in oil fields, refineries, oil depots, ships, large-scale chemical plants, chemical fiber factories, petrochemical enterprises, chemical product warehouses, solvent factories, etc.

21. The fire extinguisher should be stored in a cool, dry, well-ventilated environment with temperatures between -5℃ and 40℃, and has a shelf life of two years.

22. FP/AR - 3%, 6% Type Fluoroprotein Alcohol-Resistant Foam Fire Extinguishing Agent: Fluoroprotein alcohol-resistant foam extinguishing agent is refined by adding appropriate alcohol-resistant agents, film-forming aids, hydrocarbon surfactants, and other additives to the fluoroprotein foam extinguishing agent.

FP/AR - 3%, 6% Type Fluoroprotein Anti-Soluble Foam Fire Extinguisher: A foam fire extinguisher that combines the function of extinguishing oil fires with fluoroprotein foam and the ability to extinguish alcohol fires with anti-soluble foam.

24. FP/AR --- 3%, 6% Type Fluoroprotein Antisoluble Foam Fire Extinguishing Agent: Can be mixed with fresh or saltwater at a ratio of 3:97 or 6:94 in various low expansion foam-producing equipment to generate foam.

25. FP/AR --- 3%, 6% Type Fluoroprotein Anti-Soluble Foam Fire Extinguishing Agent: Suitable for extinguishing oil fires, as well as fires involving flammable polar solvents such as alcohols, ethers, ketones, and aldehydes.

26. FP/AR - 3%, 6% Type Fluoroprotein Antisoluble Foam Fire Extinguishing Agent: Widely applicable to large petrochemical enterprises, chemical fiber plants, oil depots, solvent factories, breweries, chemical product warehouses, ships, airports, oil drilling platforms, storage and transportation wharfs, with an effective period of two years.

27. Foam Cannon: The air foam cannon is a fire fighting cannon that produces and喷射 foam, used for extinguishing Class A, B, and C liquid fires at a distance or for spraying water, as well as for extinguishing solid material fires. It is suitable for petrochemical companies, storage areas, airports, warehouses, port terminals, and also for vessels, offshore fixed platforms, and fire trucks, among other facilities.

28. The main material of fixed fire hoses includes stainless steel, carbon steel, and aluminum alloy; they come in two types based on the horizontal and vertical angles of the fire hose jet: handle-type and wheel-type; the handle adjustment relies on the internal rotating mechanism of the cannon body.

29. The handwheel adjustment for fixed fire hoses is achieved through the worm and worm gear mechanism inside the cannon body; suitable for large space warehouses, museums, exhibition halls, archives, aircraft hangars, gymnasiums, meeting rooms, studios, and ancient buildings.

30. Fixed fire hoses are suitable for harsh working environments such as dust, corrosive gases, high and low temperatures, etc.; important sites in industries like petrochemical, metallurgy, and power, such as oil storage areas, oil depots, oil terminals, high-temperature furnaces, cable trenches; fire trucks, fireboats, oil tankers, ports, and oil fields.

31. Foam Fire Extinguisher: A crucial component of the foam fire suppression system, particularly suitable for areas with fire hazards involving flammable and combustible liquids, especially in production, storage, and usage facilities where large areas are at risk.

32. Foam Fire Extinguisher Working Principle: The foam fire extinguisher is mainly composed of flanges, cylinder, ball valve, internal connection, fire hose threads, and end caps. It is distributed and installed at predetermined locations within the protected area. The flange is connected to the supply pipeline, with the ball valve closed and the end cap sealed during normal operation.

33. Foam Fire Extinguisher Working Principle: In case of a fire, first unscrew the end cap, then attach the fire hose, and open the ball valve to supply foam liquid to the foam generator. The foam fire extinguisher must be used within the specified pressure range.

34. High Multiple Air Foam Generator: Capable of quickly mixing foam solution with air to form a large amount of foam, which rapidly covers the burning area, isolating it from air and achieving the purpose of extinguishing the fire.

35. High Multiplication Air Foam Generator: The high multiplication foam uses less water, resulting in minimal water damage. It effectively removes smoke and toxic gases, suitable for full or partial flooding in confined spaces. Used in aircraft hangars, car parks, oil depots, mines, liquefied petroleum gas stations, oil terminals, libraries, archives, and other similar venues.

36. Low-Expansion Air Foam Generator: A device that mixes foam concentrate from a proportioning system with inhaled air to produce foam, which is then sprayed onto the surface of the burning liquid to form a foam layer. This layer isolates the air, absorbs heat, and thereby extinguishes the fire. Generally used for extinguishing Class A and B fires, it is primarily intended for oil fires.

37. Medium-Expansion Air Foam Generator: Composed mainly of nozzles, foaming meshes, and foam nozzles, this device is used to produce and discharge medium-expansion foam. It can be matched with foam fire trucks, water tank fire trucks, and portable fire pumps with pipeline-type proportioning mixers. It uses medium or high-expansion foam extinguishing agents to generate medium-expansion foam.

38. Medium Multiplicity Air Foam Generator: Suitable for extinguishing fires involving petroleum products and solid materials. Widely applicable in small to medium-sized warehouses, coal mines, chemical production workshops, ships, garages, and aircraft hangars.

39. Portable Foam Fire Extinguisher: The portable foam extinguishing cart consists mainly of an atmospheric foam liquid storage tank, foam lance, pipeline type proportioning mixer, fire hose, and cart frame. Simply connect the fire hose provided with the unit to a fire hydrant or other water supply equipment to use, and it can be placed in a favorable position for extinguishing fires.

40. Mobile Push-Cart Foam Fire Extinguishing Units: As a supplement to fixed fire extinguishing equipment, these units are used for fire protection of multiple devices within the protected area. Suitable foam liquid types can be selected as needed for extinguishing various types of liquid fires. Mobile push-cart foam fire extinguishing units are widely used in residential areas, industrial and mining enterprises, oil depots, chemical departments, heat treatment workshops, gas stations, and other locations.

41. Mobile Pushcart Foam Fire Extinguishing Device Working Principle: When extinguishing is required, connect the foam gun and proportioning mixer with a firehose. Connect the firehose to the inlet of the proportioning mixer and introduce pressurized water. As the pressurized water flows at a high speed through the nozzle of the proportioning mixer, a negative pressure is formed inside the mixer. Under the action of atmospheric pressure, foam liquid from the foam liquid storage tank enters the proportioning mixer through a suction tube. It is mixed with the pressurized water in a predetermined ratio to form a foam mixture. When the foam mixture, under certain pressure, passes through the foam gun, it吸取air, causing the mixture to foam and spray over the burning liquid surface, extinguishing the fire.

42. Pressure-foam Ratio Mixture Unit (Vertical): Composed of foam liquid storage tank, capsules, pressure ratio mixer, safety valve, control valve, and some auxiliary components. When the fire suppression water pressure flows through this equipment, the ratio mixer diverts it proportionally. A small portion of the water enters the sandwich layer of the foam liquid storage tank equipped with capsules, squeezing the capsules. The displaced foam liquid is mixed with the fire water in the main pipeline to form a foam mixture of a certain ratio, which is then supplied to the foam generating equipment.

43. Pressure-Driven Foam Ratio Mixing Unit (Vertical): Features compact design and facilitates zonal protection, suitable for foam systems with multiple fire divisions and a requirement for minimal foam tank space occupancy. More space-saving on the ground for foam tanks with the same foam liquid storage capacity.

44. Pressure-Driven Foam Ratio Mixing Device (Vertical): Suitable for mixing ratios of 3% or 6% for various foam liquids, this device is widely used in oil storage tank areas, chemical factories, aircraft hangars, oil fields, fuel power plants, boiler rooms, underground garages, hazardous material warehouses, and chemical product warehouses, as well as water spray --- foam interconnection systems.

45. Pressure-Driven Foam Ratio Mixing Unit (Horizontal Type): It consists of a foam liquid storage tank, capsules, pressure ratio mixer, safety valve, control valve, and some auxiliary components. When fire water flows through this equipment, the ratio mixer diverts it proportionally. A small portion of the water enters the interlayer of the foam liquid storage tank equipped with capsules, squeezes the capsules, and the displaced foam liquid mixes with the fire water in the main pipeline to form a foam mixture of a certain ratio, which is then supplied to the foam-producing equipment.

46. Pressure-foam Ratio Mixture Device (Horizontal Type): Suitable for mixing various foam liquids with ratios of 3% or 6%. This device is widely used in oil storage tank areas, chemical factories, aircraft hangars, oil fields, fuel power plants, boiler rooms, underground parking garages, hazardous material warehouses, and chemical product warehouses, as well as water spray systems integrated with foam----combined systems.

47. Balanced Foam Ratio Mixing System: In foam fire suppression systems, large-scale foam fire protection projects place higher demands on the supply source of foam mixture. The limited foam liquid supply of traditional pressure storage tank foam ratio mixing systems is increasingly unable to meet the requirements of modern large-scale foam fire protection projects.

48. Balanced Ratio Foam Mixing Device: This is a new type of foam fire extinguishing device that supplies foam concentrate to foam fire protection systems, primarily used for medium to large-scale foam fire protection systems in places such as petrochemical industries, ports, oil depots, airports (warehouses), and offshore platforms.

49. Balanced Foam Ratio Mixing System Advantages: Utilizes atmospheric pressure, bagless, stainless steel (fiberglass) foam liquid storage tanks, avoiding losses due to capsule damage and high pressure vessel manufacturing costs.

50. Balanced Foam Ratio Mixing Device Advantages: The device is suitable for any foam extinguishing agent, including protein, fluoroprotein, and aqueous film-forming foams.

51. Balanced Foam Ratio Mixing Device Advantages: Foam liquid can be added during the extinguishing process of the device, particularly suitable for medium to large-scale foam fire protection projects. The dynamic adjustment of the balancing valve ensures the mixing ratio.

52. Balanced Foam Ratio Mixing Device Advantages: The supply method of the foam pump injecting foam liquid allows for a wide range of working pressure and flow rates in the foam mixture. Operation is simple and more conducive to automation control.

53. Foam fire extinguishing systems emit a high-visibility water mist during operation, which can reduce smoke content and toxicity at the fire scene, benefiting both evacuation and firefighting efforts. They mainly consist of two types: portable handheld foam extinguishers and trolley-mounted foam extinguishers, as well as air foam extinguishers. Each type of extinguishing device is suitable for different types of fires.

54. Foam Fire Extinguishing Systems: 1. Portable foam extinguishers are suitable for extinguishing general Class B fires, such as those involving oil products and greases, and can also be used for Class A fires. However, they are not effective against fires involving water-soluble combustible or flammable liquids like alcohols, esters, ethers, and ketones; they cannot extinguish fires involving electrical equipment, Class C, or Class D fires. 2. Wheeled foam extinguishers are suitable for general Class B fires, such as those involving oil products and greases, and can also be used for Class A and F fires. They are not effective against Class C, D, or E fires. 3. Air foam extinguishers are primarily used for extinguishing initial fires involving combustible liquids like gasoline, kerosene, diesel, vegetable oil, and greases. They can also be used for initial fires involving combustible solids like wood, cotton, and paper.

55. Pressure-Proportional Mixing Device: The pressure-proportional mixing device consists of two parts: a foam liquid pressure storage tank and a foam proportioning mixer. It is a device used for storing foam liquid and mixing it with water in a fixed ratio. Features: 1. The system does not require a separate foam liquid pump; it can directly use fire hydrant pressure water to drive the foam liquid, saving equipment costs. 2. The mixing ratio is accurate and stable, ensuring the correct proportion for foam fire extinguishing, making the extinguishing quick and reliable. 3. Low pressure loss ensures the necessary pressure for foam-producing equipment at the system's end. 4. Foam liquid and water are separated by a bladder, preventing the foam liquid from degrading after single use, facilitating usage, tuning, and routine testing. 5. Easy to operate and maintain, with a small footprint, suitable for automatic control. 6. Available in various capacities of foam liquid storage tanks and different flow ratio mixers to meet the needs of various foam-producing equipment. 7. Widely applicable in low, medium, and high expansion foam fire extinguishing systems.

56. Foam fire suppression systems are categorized by their structural design into fixed, semi-fixed, and portable types. A semi-fixed system consists of a fixed foam generator, partially connected piping, a foam fire truck, or a mobile pump, all connected with hoses to form a fire suppression system.

57. The Foam Mobile System refers to a fire extinguishing system composed of fire trucks, mobile fire pumps, or pressurized water sources, foam proportioning mixers, foam guns, foam cannons, or portable foam generators, connected by hoses and other components.

58. Foam Fire Extinguishing System: Offers advantages such as resistance to oil contamination, the use of inexpensive ordinary protein foam, etc. It comes in three application forms: fixed, semi-fixed, and mobile. Submerged liquid systems are typically designed as fixed or semi-fixed.

59. Foam Fire Extinguishing System: For water-soluble liquid fires, it is mandatory to use a non-soluble foam liquid. When extinguishing water-soluble liquid fires, use overhead or semi-submerged jet foam; do not use submerged jet foam.

60. Foam Fire Extinguishing System: For non-aqueous liquid fires, protein, fluoroprotein, film-forming fluoroprotein, or aqueous film-forming foam can be used for overhead foam extinguishing.

61. Foam Fire Extinguishing System: When using foam extinguishing by submersion, it is mandatory to choose fluoro protein, film-forming fluoro protein, or water-forming foam liquid. The storage temperature for the foam liquid should be between 0-40°C.

62. Foam Fire Extinguishing System: Divided into low expansion, medium expansion, and high expansion foam fire extinguishing systems. The low expansion foam fire extinguishing system is suitable for fire protection systems in places such as Class A, B, and C liquid storage tanks, and petrochemical equipment areas.

63. Foam Fire Extinguishing Systems: Divided by system type: flooding systems, local application systems, portable systems, foam-water spray systems, and foam mist systems.

64. Foam Fire Extinguishing System: Low expansion foam fire extinguishing systems are suitable for fixed-roof storage tanks containing non-aqueous liquids. They are not suitable for water-soluble liquids and fixed-roof storage tanks containing classes A, B, or C liquids that are destructive to ordinary foam, nor are they suitable for external and internal floating roof tanks.

65. Low-expansion foam fire extinguishing system: Foam guns are suitable for: 1) Non-aqueous liquid fixed-roof storage tanks with diameters less than 18 meters. 2) Liquid fire outbreaks of Class A, B, and C within embankments. 3) Class A, B, and C liquid tanker truck racks or train tanker racks. 4) Outdoor liquid fire outbreaks of Class A, B, and C. 5) Aircraft hangars.

66. Medium-Density Foam Fire Extinguishing System: Local Application System: A Class fire locations with partial enclosure, scattered B Class fire locations at designated areas, and flowing B Class fire locations with fixed positions not exceeding 100 square meters in area.

67. High-Expansion Foam Fire Extinguishing System: Local Application System - Suitable for Class A fire locations with incomplete enclosure on all sides, also applicable to condensate pools or containment areas of natural gas liquefaction stations and receiving stations.

68. High-expansion foam fire suppression system: Portable systems for areas where the fire location is difficult to determine or where access is challenging for personnel, for Class B fires with flowing flames, and for enclosed spaces requiring smoke extraction, cooling, or harmful gas removal during a fire.

69. Foam Fire Extinguishing System: Selection and Installation Requirements for Foam Fire Pumps and Foam Mixing Pumps: Foam fire pumps and foam mixing pumps should be selected as centrifugal pumps with a smooth characteristic curve, and their working pressure and flow rate should meet the system design requirements: When using a hydraulically driven balanced ratio blending device, the water flow rate consumed should be included in the rated flow of the foam fire pump; When using a recirculating pump type ratio blender, the rated flow of the foam mixing pump should be 1.1 times the system design flow; A vacuum pressure gauge or vacuum gauge should be installed on the pump inlet pipeline; A pressure gauge, check valve, and a return pipe with a control valve should be installed on the pump outlet pipeline.

70. Foam Fire Extinguishing System: Selection and setup requirements for foam liquid pumps: The working pressure and flow rate of the foam liquid pump should meet the system design requirements and match the working pressure and flow rate range of the selected proportioning device. At the same time, the foam liquid supply pressure at the design flow rate should be greater than the water pressure. The structural form, sealing or filling type of the foam liquid pump should be suitable for transporting the selected foam liquid, with materials that are resistant to corrosion by foam liquid and do not affect the performance of the foam liquid. A standby pump should be equipped, with the specifications and models of the standby pump identical to the working pump. In case of a failure of the working pump, it should be able to switch automatically or manually to the standby pump. The foam liquid pump should withstand at least 10 minutes of no-load operation; in addition to hydraulic-driven pumps, a power source should be set up.



Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery HebeiShijiazhuang3dayswithin
Stock 1000IndividualMOQ1Individual
Brand Jianghe
Is importing No
Usage Fire Extinguisher
Is cross-border sourcing available? No
Expiry Long Valid
Update 2023-05-27 09:47
Gallery

Hebei Shenghe Fire Protection Equipment Co., Ltd.Published byFoam Fire ExtinguisherGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top