Hebei Shenghe Fire Protection Equipment Co., Ltd.VIP

消防设备、电子产品、制冷设备、环保设备、水处理设备
Enter Shop

Manual Water Cannon

平台认证
  • Unit Price

    Negotiable

  • Brand

    Jiang He

  • MOQ

Contact
Leave Msg

Platform Service

Supplier Verified



河北圣河消防设备有限公司

VIP   数字营销第3年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    Jiang He

  • Unit Price:

    Negotiable

  • MOQ:

  • Total:

    0

  • Address:

    HebeiShijiazhuang

  • Delivery:

    3days

  • View More

Description

Water Cannon Network Promotion Article

The Automatic Tracking and Locating Jet Fire Extinguishing Device is a high-tech fire protection product developed through the innovative technology alliance of the second-generation fire lance, integrating automatic alarm, fire tracking, automatic extinguishing, and video monitoring into one.

2. The automatic tracking and positioning jet fire extinguishing device leads with a patented infrared thermal imaging positioning technology. In addition to the commonly used active red and ultraviolet single-point narrow-slot detection technology for fire source, it features automatic positioning, targeted water jetting at the fire point, automatic valve closure post-extinguishing, and the ability to restart upon reignition. Furthermore, it boasts a real-time dynamic tracking function for changing fire sources, ensuring more accurate positioning.

3. The automatic tracking and positioning jet fire suppression system is suitable not only for general fire monitors' applications but also for places where UV lights, electric welding, and outdoor cutting environments are present, where conventional fire hoses are not ideal. It is also ideal for locations that demand high precision in positioning and system reliability, necessitating round-the-clock, fully automatic operation.

4. The automatic tracking and positioning jet fire extinguishing device is easy to install, with simple water and power supply, low maintenance costs, water-saving, and significantly reduces the risk of flood damage after extinguishing. It offers high cost-performance and is widely used in high and large spaces such as cinemas, warehouses, factories, stadiums, grand halls, waiting halls, exhibition centers, hotels, and parking lots.

5. Automatic tracking and positioning jet fire suppression systems are not suitable for environments where open flame production is normally used.

6. Automatic tracking and positioning jet fire extinguishing devices are not suitable for Class B, C, and D fire situations.

7. Automatic tracking and positioning jet fire suppression systems are not suitable for areas containing a large number of items that burn faster when wet.

8. Automatic tracking and positioning jet fire extinguishing devices are not suitable for locations where explosions occur upon contact with water.

9. Automatic tracking and positioning jet fire suppression systems are not suitable for locations where there are items that undergo intense chemical reactions or produce toxic substances when exposed to water.

10. Automatic tracking and positioning jet fire suppression systems are not suitable for locations where liquid splashing or boiling over may occur due to sprinkling.

11. Automatic tracking and positioning jet fire extinguishing devices are not suitable for locations housing valuable items that would sustain severe damage upon contact with water, such as archives, valuable document repositories, and museum珍品rooms.

12. Automatic tracking and positioning jet fire suppression systems are not suitable for locations where significant property damage is caused by high-altitude water cannons' impact.

13. Automatic tracking and positioning jet fire extinguishing devices are not suitable for other locations where large-scale active water sprinkler fire extinguishing systems are not advisable.

14. The Automatic Tracking and Locating Jet Fire Extinguishing Device is an integrated automated fire extinguishing system that combines computer technology, red and ultraviolet sensing technology, infrared thermal imaging technology, mechanical transmission technology, and image transmission technology. It actively detects the monitored area around the clock in an all-weather, fully automatic manner.

15. The automatic tracking and positioning jet fire suppression system, upon detecting a fire, promptly activates and simultaneously emits an alarm signal. It then engages the solenoid valve and pump to spray water at the fire source for extinguishing. Once the fire is extinguished, it automatically stops. If the fire reignites, it restarts.

16. The automatic tracking and positioning jet fire extinguishing device can be connected to the automatic fire alarm system and can also be integrated with on-site operation panels, fire monitor controllers, etc., to form a centralized fire extinguishing system.

17. The automatic tracking and positioning jet fire extinguishing device is easy to install, with simple water and power supply, low maintenance costs, saves water resources, and greatly reduces the risk of flood damage after extinguishing.

18. The Automatic Tracking and Positioning Jet Fire Extinguishing Device utilizes the tracking and guidance technology of air-to-air missiles. Its core components employ infrared thermal imaging sensors and array scanning positioning principles. In addition to general civil applications, it is also suitable for complex industrial factory warehouses, certain outdoor environments, or locations with high reliability requirements for the system.

19. The automatic tracking and positioning jet fire suppression device abandons the narrow slit technology and adopts the same principle as the real-time tracking of the tail flame heat imaging guidance of air-to-air missiles. Its core technology employs a non-cooled focal plane array thermal imaging sensor with real-time temperature measurement capabilities. The core positioning technology is a combination of thermal imaging sensor + inertial navigation = real-time tracking technology.

20. The automatic tracking and positioning jet fire suppression device scans for fires using a surface thermal imaging array sensor for image scanning. Each pixel's temperature is calculated in real-time. Once detected, it locks on immediately, tracks the dynamic fire source in real-time, analyzes the fire source situation intelligently, and aims to spray water at the fire source, featuring safety, reliability, and convenience.

21. The core positioning component of the automatic tracking and positioning jet fire suppression system utilizes a non-cooled staring array thermal imaging sensor.

22. The automatic tracking and positioning jet fire suppression system, in addition to the point-type wide-angle UV flame detector, also features thermal imaging sensor temperature activation, ensuring no false alarms.

23. Automatic Tracking and Locating Jet Fire Extinguishing Device with Thermal Imaging + Inertial Navigation System = Real-time Tracking; immediately lock and track the dynamic fire source upon detection.

24. Automatic tracking and locating jet fire suppression device with laser red dot indicator, point and shoot, man-machine integration for greater reliability.

25. The main unit of the automatic tracking and positioning jet fire extinguishing device features a remote rod for real-time stepless speed control of the water cannon, allowing you to aim where you point. It can also be used as a fast-motion video surveillance camera during normal operation.

26. The automatic tracking and positioning jet fire suppression device's moving parts are fully sealed, dust-proof, and can maintain long-term automatic standby to ensure the safety of the protected area.

27. The automatic tracking and positioning jet fire extinguishing device can be individually set to the automatic or manual mode of four modes: water cannon, valve, pump, and laser, facilitating management.

28. The automatic tracking and positioning jet fire suppression unit's main body can set weekly calendar periods for each cannon, automatically scheduling the manual-to-automatic switch of the water cannon's functions.

29. The main unit of the automatic tracking and positioning jet fire extinguishing device can not only operate the water cannon and view and adjust the parameters of the water cannon, but also remotely update the program for convenient maintenance and repair.

30. The core positioning component of the automatic tracking and positioning jet fire extinguishing device utilizes non-cooled focal plane infrared thermal imaging technology, with image scanning. Once locked on, it can track the dynamic fire source in real-time.

31. The Automatic Tracking and Locating Jet Fire Extinguishing Device System integrates three control methods: fire automatic alarm, on-site manual control, and centralized control from the central control room.

32. The Automatic Tracking and Positioning Jet Fire Extinguishing Device Water Gun Controller features a Chinese character color LCD touch screen, with an integrated printer for real-time emergency situation printing.

33. The automatic tracking and positioning jet fire suppression device comes with a four-axis remote rod for easy remote control of the water cannon's up, down, left, and right movements.

34. The automatic tracking and positioning jet fire extinguishing system features a timed conversion function. For each fire extinguishing device, multiple time periods can be set, and the system automatically completes the manual/automatic function switch of the water cannon at the set time.

35. The Automatic Tracking and Locating Jet Fire Extinguishing Device System features automatic interlock functionality, enabling automatic interlock between water cannons within the protected area—a single alarm activates the entire system.

36. The automatic tracking and positioning jet fire extinguishing device can be individually set to the automatic or manual status of water cannons, valves, water pumps, and sound-light modes, facilitating management.

37. Each area exit of the automatic tracking and positioning jet fire suppression device allows observation of all fire hoses within the area. The on-site operation panel controls all water spray fire suppression settings within the area. It displays nozzle selection, communication, audible and visual alarms, device fault indication, and mute status via a Chinese character LCD. Functional operations such as up, down, left, right directions, valve and pump on/off are performed through buttons. The on-site operation panel should be installed at a height of 1.5 meters from the ground, with no obvious obstructions around.

38. The water cannon controller for automatic tracking and positioning jet fire suppression systems allows for remote viewing and adjustment of all parameters, as well as remote updating of the water cannon's program.

The operating components of the automatic tracking and positioning jet fire extinguishing device should be fully sealed; no gears should be visible at the openings to prevent dust from entering and affecting long-term stable operation.

40. The fire suppression components of an automatic tracking and locating jet fire suppression system should be integrated with a laser red dot indicator for easy verification of correct positioning at any time.

41. The automatic tracking and positioning jet fire extinguishing device utilizes masterless bus communication technology. A single loop supports up to 9999 bus devices, with the first two digits indicating the zone number and the last two digits indicating the cannon number.

42. The automatic tracking and positioning jet fire extinguishing device uses a single outlet, with concentrated water flow, strong penetration power on the fire scene, less prone to atomization, and effective in extinguishing early-stage fires.

43. The signal bus of the automatic tracking and positioning jet fire extinguishing device must be a daisy chain structure without any branches.

44. The video line for the automatic tracking and positioning jet fire suppression system is point-to-point structured. Each water cannon has a separate video line that is directly pulled to the video host. When the distance exceeds 300 meters, optical fiber transmission should be used, and a photoelectric repeater should be added for transmission.

45. The automatic tracking and positioning jet fire suppression system uses metallic pipes or metal conduits for wiring. Wires of different systems and voltages must not be installed in the same conduit or conduit channel. The power supply for the system should use AC220 fire protection power supply, and electricity should not be taken locally.

46. Each fire compartment of the installation site for the automatic tracking and positioning jet fire extinguishing device should be equipped with at least one on-site operation panel. Networked via CAN bus, the main unit remotely monitors the fire situation in conjunction with the on-site video surveillance system, enhancing the联动 decision management capabilities.

47. Automatic tracking and positioning jet fire extinguishing nozzles, site operation panels, and intelligent end-of-line test devices, each occupying a single bus address point, are all connected in parallel to the CAN bus without any branching in between.

48. The video lines for the automatic tracking and positioning jet fire extinguishing device use the same wiring method as the security system, i.e., a video line is placed from the video host to each fire extinguishing device. The video cable should be of type SYV75-5. When the length of the video line exceeds 300 meters, fiber-optic transmission should be used for the video signal.

49. To connect the water cannon of an automatic tracking and positioning jet fire suppression system to the fire alarm system, simply add an input module to the passive alarm terminal of each water cannon's electrical control box to upload the water cannon alarm signal to the fire alarm system; adding an input/output module will enable the联动 water cannon activation function with the fire alarm system.

50. The water cannon of the automatic tracking and positioning jet fire suppression device can be installed by overhead, suspended, or wall-side methods. Regardless of the installation method, ensure the nozzle is vertically downward and freely rotating. A vertical DN50 flange is pre-installed 50cm away from the wall or other obstructions at the end of the water pipeline. Use a rubber flat washer for sealing; metal washers are strictly prohibited. During installation, temporarily install two downward bolts on the upper flange first. Once the nozzle is close, secure the water cannon with two nuts, then place the flat washer, and thread the bolts upwards into the opposite holes. Tighten the nuts on top, adjust the original downward bolts to face upwards, and tighten them.

                                                                                                                                                                                                                                                                          



Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery HebeiShijiazhuang3dayswithin
Brand Jiang He
Is import required? No
Usage Fire Extinguisher
Custom Processing No
Expiry Long Valid
Update 2023-05-24 17:05
Gallery

Hebei Shenghe Fire Protection Equipment Co., Ltd.Published byManual Water CannonGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top