SmokeStop (IG541)


1. The Yanbi Jingming Fire Extinguishing System is a new type of fixed clean gas fire extinguishing device developed and produced by our company in China, known for its excellent fire extinguishing effect and being purely natural.

2. The fire suppression mechanism of the Yanyi Jingming fire extinguishing system is to relatively reduce the oxygen content in the air of the burning area, lower the temperature of the combustible material, and cause the fire to suffocate, thereby achieving the purpose of extinguishing the fire—a physical action method of fire suppression.

3. Smokeless Fire Extinguishing Agent is a clean gas extinguishing agent composed of a mixture of nitrogen (N2), argon (Ar), and carbon dioxide (CO2) gases in a specific ratio.

4. The smokeless fire extinguishing agent has the following features: (1) It does not contaminate the protected objects; (2) It does not damage the atmospheric ozone layer; (3) It has no adverse effects on humans, animals, or plants; (4) It has good electrical insulation properties (non-conductive), is colorless, odorless, and harmless. Known as a "green fire protection product," it is an ideal alternative to halon fire extinguishing agents.

5. The smoke-inhibiting extinguisher, also known as a three-dimensional extinguisher, features three-dimensional movement, allowing it to extinguish both vertically and horizontally spreading flames. The fast-moving, rapidly expanding smoke-inhibiting gas can pass through obstacles and small openings to reach inaccessible, concealed fire hazards, quickly extinguishing the flames.

6. Our smoke extinguishing system, developed and produced domestically, has been certified as a green product by China's Environmental Protection Bureau. It boasts safety, practicality, advanced technology, reasonable pricing, short production cycle, high contract fulfillment rate, excellent after-sales service, and low cost (just 1/3 to 1/2 of similar products abroad). The product is insured by the People's Insurance Company of China, ensuring that users benefit from our insurance even if they do not purchase their own coverage.

7. Features of the Smoke Must Static Fire Extinguishing System: The container valve employs a metal diaphragm sealing design, ensuring highly reliable sealing performance, making it possible to store the fire extinguishing agent.

8. Structural Features of Yanbi Jinghong Fire Extinguishing System: Multiple start-up methods (electric start, gas start, electrical manual start, and emergency mechanical manual start) ensure reliable system start-up.

9. Structural Features of the YANBIJING Fire Extinguishing System: Utilizes throttle orifice plates to reduce pressure in the piping, ensuring enhanced safety.

10. Structural Features of the YANBIJING Fire Extinguishing System: Special electric starting device -- minimizes the starting current, effectively resolves issues such as high power consumption in the control section, significantly reduces the volume of the battery, making the system layout more compact and reasonable.

11. Fire Extinguishing System by YANBIJING is suitable for: liquid or fusible solid fires (such as paraffin, asphalt), surface fires of solids, and deep-seated fires of some solids (such as cotton, paper).

12. Application Scope of Yanbi Jinghong Fire Extinguishing System: Electrical equipment fires, such as transformers, switches, generators, motors, etc., gas fires (excluding those that cannot have the gas source cut off before extinguishing), such as methane, ethane, propane, and city gas.

13. Application of Smoke-Ban Static Fire Extinguishing System: Electronic computer rooms, transformer rooms, switch rooms, generator sets, metal rolling units, quenching oil tanks, communication rooms, electrical and instrument control centers, etc.

14. Applicable locations for the YANBIJING fire extinguishing system: Aircraft engine compartments, ship engine rooms, car parks, engine laboratories, oil tanks, oil storage rooms, oil pump rooms, hazardous material warehouses, electrostatic paint spray rooms, reactors, etc. Library storage rooms, data storage rooms, bank vaults, cable tunnels, food warehouses, tobacco warehouses, etc.

15. The "Toxic Gas" of Yebijing Fire Extinguishing Agent: Yebijing Fire Extinguishing Agent is a pure, natural, clean extinguishing agent that is colorless, odorless, non-toxic, and tasteless, hailed as a pure natural green fire protection product. At the designed extinguishing concentration, with an oxygen content of 12% (by volume), there will be no harm to humans inside.

16. The Yanbijing Automatic Fire Extinguishing System is a full flooding fire extinguishing system, which is divided into independent unit systems and combined distribution systems according to the protected area.

17. The individual system of the YanBiJing automatic fire extinguishing system refers to a fire extinguishing system where a fire extinguishing agent storage unit protects a protected area. It is mainly used in places where the protected areas are not convenient to be combined or where two protected areas are adjacent, but there is a possibility of a fire occurring simultaneously.

18. The smoke-must-be-quiet automatic fire extinguishing system integrated distribution system refers to a fire extinguishing system that uses a set of extinguishing agent storage devices to protect multiple protected areas.

19. The Yaniu Jing Automatic Fire Extinguishing System consists of three parts: the fire alarm system, the fire control system, and the fire extinguishing system. The fire extinguishing system is further composed of the extinguishing agent storage device and the pipeline system.

20. In the event that both detectors within the protected area simultaneously trigger a fire alarm, the smoke-free automatic fire suppression system's automatic fire suppression controller will emit an electrical signal command after a delay of 30 seconds. This will initiate the electrically-powered cylinder valve and the corresponding selector valve according to a pre-set combination distribution method, thereby implementing automatic fire suppression.

21. The cylinder distribution panel of the Yanbijing automatic fire extinguishing system is designed for the combined distribution of cylinder arrangements for extinguishing agents in Area A and Area B through electrical principles, and also serves as a junction box. The panel also features a switch for switching between the main and backup cylinders.

22. When both detectors in the protected area simultaneously emit fire signals, the controller of the smoke-free automatic fire extinguishing system immediately sends telecommunication commands to open the corresponding control area's cylinder. The starting gas is divided into two paths: one passes through a seven-way one-way valve to open the selector valve of the corresponding protected area, and the other directly opens the extinguishing agent storage group to extinguish the fire in the protected area.

23. Yanyi Jing Automatic Fire Extinguishing System: In the event of failure of the electric or pneumatic start, staff can manually open the corresponding selector valve and cylinder valve at the equipment site to initiate fire extinguishing. The emergency start cut-off box is used to manually initiate or stop the fire extinguishing system at the protected site.

24. Environmental requirements for the Yanbi Jing Automatic Fire Extinguishing System: The temperature in the cylinder storage room should be between 0°C and 50°C, and cylinders should not be directly exposed to sunlight or placed near heat sources.

25. Environmental Requirements for the Yanbi Jing Automatic Fire Extinguishing System: The pipe network storage room should be located in a room that is easily accessible by personnel, convenient for entry and exit, and not prone to fire.

26. Environmental Requirements for the Yanbi Jing Automatic Fire Extinguishing System: The cylinder storage room should be located away from environments prone to vibration, impact, and corrosion.

27. Installation requirements for the Yanyi Jing Automatic Fire Extinguishing System: The cylinder rack should be securely mounted on the wall or floor, with ample space around it for easy installation, inspection, and maintenance of the device.

28. Installation requirements for the Yanbijing Automatic Fire Extinguishing System: The collection pipe should be cleaned internally and进出口 sealed prior to installation. It should be securely mounted on supports or frames, ensuring the supports or frames are firmly fixed and undergo corrosion prevention treatment. The exterior surface of the collection pipe should be coated with red paint.

29. Installation requirements for the Yanbi Jing automatic fire extinguishing system: The collection pipe equipped with a pressure relief device should not have the pressure relief direction facing the operational surface.

30. Installation requirements for the Yanbi Jing automatic fire extinguishing system: The installation of the valve should ensure that the manual handle is on one side of the operating surface. Measures for easy operation should be taken when the installation height exceeds 1.7m.

31. Installation requirements for the Yanbi Jing automatic fire extinguishing system: The selected valve with threaded connections should be fitted with a flexible joint at the pipe connection.

32. Installation requirements for the Yanbi Jing automatic fire extinguishing system: The fire extinguishing agent supply pipes passing through walls and floors should be fitted with conduit sleeves. The length of the sleeve passing through the wall should be equal to the wall thickness, and the length of the sleeve passing through the floor should be 50mm above the ground. The gap between the pipe and the sleeve should be filled with a flexible, non-combustible material to be tightly packed. The outer surface of the fire extinguishing agent pipe should be painted red.

33. Installation requirements for the Yanbi Jing Automatic Fire Extinguishing System: The assembly of steel cylinders, valves, and other equipment should be sturdy, reliable, and maintain sealing integrity. The pneumatic start-up pipeline is an essential part of the system's startup, and there should be no leaks between the copper pipes and their fittings.

34. Installation Requirements for the Yanbijing Automatic Fire Extinguishing System: The equipment should be installed under the guidance of the supplier's technical personnel, and after installation, the system should undergo debugging (mechanical, electrical control aspects) and inspection.

35. Installation requirements for the Yanbi Jing automatic fire extinguishing system: During the inspection and debugging process, the power lines must be disconnected to avoid unnecessary losses.

36. Installation Requirements for the YanBiJing Automatic Fire Extinguishing System: After equipment installation and debugging are completed, the fire extinguishing device should be in the automatic extinguishing mode.

37. Caution for installing the Yanbi Jing Automatic Fire Extinguishing System: Pay attention to the correct orientation of the one-way and selector valves during installation; do not reverse the inlet and outlet.

38. Important Notes for the Yanbijing Automatic Fire Extinguishing System: Determine the corresponding number of extinguishing agent storage cylinders for each protected area based on the amount of extinguishing agent required, and then properly connect the pneumatic piping and directional valves to ensure that the operation and the amount of extinguishing agent (number of cylinders) released (opened) in each protected area meet the design specifications.

39. Safety Precautions for the YBJQ Automatic Fire Extinguishing System: The safety pin on the pneumatic bottle head valve and the fire extinguishing agent bottle head valve is always in a sealed state. The safety pin is only removed manually to break the seal when the system is initiated.

40. Safety Precautions for the Yanbi Jing Automatic Fire Extinguishing System: During installation, be sure to fit the assembly seal on both ends of the metal flexible hose.

41. Safety Precautions for the YB Jing Automatic Fire Extinguishing System: The pneumatic cylinder is filled to a pressure of 10MPa. If the pressure drops below 6MPa due to chronic leaks or other reasons, it must be refilled to 10MPa and a leak tightness test must be conducted to ensure the reliability of the system's pneumatics.

42. Precautions for the YANBIJING Automatic Fire Extinguishing System: All connections in the piping, particularly the pneumatic start-up piping, should be reliable and free of any leaks.

43. Important precautions for the installation of the Yanbijing Automatic Fire Extinguishing System: Strictly avoid any impact on the system components during installation, especially the bottle head valve and the filling valve on top of it, as well as the piston assembly. Failure to do so may lead to damage and even pose a risk to personal safety.

44. Precautions for the Yanbi Jing Automatic Fire Extinguishing System: The wiring of the alarm and control section (electrical part) must be ensured to be accurate and reliable, with no misconnections.

45. Emergency response to urgent faults of the Yanejing automatic fire extinguishing system: In case of a fire, if the automatic alarm control cabinet loses its extinguishing function, the following steps should be taken to activate the fire extinguishing system: a) First, pull the safety pin on the cylinder in the burning area, pull out the handle to start the extinguishing system. b) After the above steps, if the bottle head valve of the storage cylinder cannot be opened, use the method in step a to open the bottle head valve of the starting cylinder. If the selector valve for the fire point area is not open, turn the handle on the selector valve to use the gas from the extinguishing agent inside the pipeline to open the selector valve, release the extinguishing agent, and thereby activate the entire fire extinguishing system.

46. Caution for the YanBiJing Automatic Fire Extinguishing System: In case of a false alarm without a fire occurring, press the reset button to reset the main unit. Alternatively, first press the emergency shutdown button, then the reset, to bring the main unit back to normal operation.

47. The Yanyi Jing automatic fire extinguishing system should be regularly inspected and maintained by a dedicated person who has been specially trained and passed the examination.

48. Upon the commissioning of the Yaniu Jing automatic fire extinguishing system, the following documents should be in place: 1) Approved completion acceptance application report. 2) Construction records and intermediate acceptance records of concealed works. 3) Completion drawings and written records of design changes. 4) Completion report, design specifications, and debugging report. 5) User and maintenance manuals for the system and its main components. 6) Inspection reports, test reports, and factory certificates of conformity for system components, piping materials, and pipe accessories. 7) Completion acceptance report, operational procedures for the system, and records and charts of system inspections and maintenance.

49. The Yanbijing Automatic Fire Extinguishing System shall undergo two inspections in accordance with the regulations for the gas fire extinguishing system, with the inspection contents and requirements as follows: 1) Conduct an external inspection of all system components, including the extinguishing agent storage containers, selector valves, liquid one-way valves, high-pressure hoses, collecting pipes, valve drive units, piping, and nozzles. The system components should be free from collision deformation and other mechanical damage, with no rust on the surface, intact protective coatings, clear labels, and protective covers, lead seals, and safety signs on manual operation devices should be in good condition. 2) The pressure inside the Yanbijing extinguishing agent storage container should not be less than 90% of the design pressure. 3) The pressure of the pneumatic drive unit's pneumatic source should not be less than 6MPa.

50. The Yanbijing Automatic Fire Extinguishing System should undergo two inspections of the gas extinguishing system annually. The inspection content and requirements, in addition to the monthly checks, should comply with the following provisions: 1) The openings in the protected area, the use of the protected area, and the types, quantities, and distribution of combustible materials should meet the design specifications. 2) The equipment in the extinguishing agent storage room, the extinguishing agent supply pipes, and the supports and hangers should be securely fastened without any looseness. 3) All nozzle openings should be unobstructed. 4) In case of damage and blockage in the extinguishing agent supply pipes, conduct a tightness test and blow cleaning.

51. The YANBIJING fire suppression system's YANBIJING cylinders, in accordance with the "Regulations for Safety Supervision of Gas Cylinders," are to be inspected every five years for cylinders containing inert gases. If severe corrosion, damage, or doubts about their safety and reliability are found during use, an inspection should be conducted in advance.



Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery HebeiShijiazhuang3dayswithin
Stock 1000PieceMOQ1Piece
Brand Jiang He
Is importing No
Usage Fire Extinguisher
Appearance color Red
Expiry Long Valid
Update 2023-05-24 17:05
Gallery

Hebei Shenghe Fire Protection Equipment Co., Ltd.Published bySmokeStop IG541 Fire Extinguishing EquipmentGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top