Kehua UPS Power Supply Rental | Exhibition UPS Power Supply Rental

平台认证
  • Unit Price

    $1.00/Unit

  • Brand

    Jia Ming恒达Technology

  • MOQ

    1Unit

Contact
Leave Msg

Platform Service

Supplier Verified



北京嘉铭恒达科技有限公司

VIP   标王第3年
资料通过中商114认证
Category
  • No Category

Product Details

Specs

Gallery

  • Brand:

    Jia Ming恒达Technology

  • Unit Price:

    $1.00 / Unit

  • MOQ:

    MOQ1Unit

  • Total:

    999Unit

  • Address:

    Beijing

  • Delivery:

    3days

  • View More

Description

Jiaming Power UPS Battery Rental offers various battery configuration solutions. Typically, UPS power sources on the market are identified by their capacity: smaller ones are marked in "W" (watts); those over 1 kilowatt-hour use "VA" (volt-amps). The "W" and "VA" values differ. This necessitates selecting the appropriate UPS based on specific situations. Generally, small capacity UPS systems (1 kilowatt or less) are marked in "W" for their capacity, while UPS systems ranging from 1KVA to 500KVA are marked in "VA" rather than "W."


How to operate the UPS power supply:

1. Mains power connected to the UPS.

2. Insert the computer's power cable and monitor power cable into the UPS's black output socket.

Not enough outlets? Simply plug in an extension cord.

3. Turn on the UPS power switch for full automatic voltage regulation.

Green light is on when the main power is normal. (UPS is off, the green light blinks automatically to charge when the main power is connected)

The battery mode yellow LED indicator is on.

The red LED indicator light illuminates and an alarm sounds when there's an abnormal power supply.

4. At startup, power on the UPS first, then turn on the computer to avoid starting with a load.

5. Power down by first turning off the computer, then the UPS.

Battery inspection should include checking for severe electrolyte loss and irreversible sulfation on the plates. Irreversible sulfation can be determined by measuring the change in terminal voltage during charge-discharge cycles; the voltage of a lead-acid battery rises rapidly, with some individual cell voltages particularly high, exceeding normal values significantly; and the voltage drops rapidly during discharge. If the battery holds little or no charge, these conditions indicate irreversible sulfation. For fault checking and treatment, first ensure the charging circuit is securely connected; replace any malfunctioning charger and perform maintenance charging and discharging to restore battery capacity. If irreversible sulfation is detected, perform an equalizing charge to recover capacity. For batteries that have been refilled with electrolyte, maintain a controlled charging current of 18A for 10-15 hours.


Generally speaking, when selecting the capacity for UPS, the following factors should be considered:

Actual Load Condition: P = ∑Pi/f

The actual load capacity P can be obtained by dividing the sum of all actual loads, ∑Pi, by the power factor f, where f ranges from 0.6 to 0.8. Calculation of UPS power supply battery runtime

Battery runtime is primarily affected by load size, battery capacity, environmental temperature, and battery discharge cutoff voltage. Generally calculated...

UPS battery runtime, calculate the battery discharge current, and then determine the discharge time by referring to the battery discharge curve. Battery discharge current

The flow can be calculated using the following empirical formula:

Discharge Current = UPS Capacity (VA) × Power Factor / Average Battery Discharge Voltage × Efficiency

To calculate the actual load discharge time, simply replace the UPS capacity with the actual load capacity.

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $1.00 / Unit
Sales None
Delivery Beijing3dayswithin
Stock 999UnitMOQ1Unit
Brand Jia Ming恒达Technology
Input Voltage 220-380
Method of Preparation Pulse Width Modulation (PWM)
Product Certification UL
Expiry Long Valid
Update 2023-10-21 17:46
Gallery

Beijing Jiaming恒达 Technology Co., Ltd.Published byKehua UPS Power Supply Rental | Exhibition UPS Power Supply RentalGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top