Jiangsu Quankun Environmental Protection Technology Co., Ltd.VIP

水处理设备、污水废水处理设备、膜分离设备、纯水装置
Enter Shop

Inspection Laboratory Wastewater Treatment Equipment - Stable Operation - Quankun Material Corrosion-Resistant and Durable

平台认证
  • Unit Price

    $34000.00/Tai

  • Brand

    Quan Kun

  • MOQ

    1Tai

Contact
Leave Msg

Platform Service

Supplier Verified



江苏权坤环保科技有限公司

VIP   数字营销第3年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    Quan Kun

  • Unit Price:

    $34000.00 / Tai

  • MOQ:

    MOQ1Tai

  • Total:

    100Tai

  • Address:

    JiangsuNanjing

  • Delivery:

    Pre-sale, after payment7days

  • View More

Description

  Certified Testing Laboratory Sewage Treatment Equipment - Stable Operation - Kuankun Material Corrosion-Resistant and Durable

A high-level automated laboratory comprehensive wastewater treatment system with excellent treatment effects, compact installation space, simple operation and management, and no need for dedicated personnel. It is specifically designed for comprehensive wastewater treatment in laboratories across various industries both domestically and internationally. Highly praised by users, it is widely used in universities, research institutions, food and drug inspection, product quality inspection organizations, disease control centers, environmental monitoring, agricultural product quality inspection, inspection and quarantine, grain and oil. It also includes testing, animal disease control, blood centers, animal husbandry and breeding, institutions, biology, petrochemical enterprises, and other laboratories and testing rooms. The treated wastewater meets the standards of the first, second, and third categories for comprehensive wastewater discharge. The effluent after treatment according to standard [GB8978-1996] can be discharged into the municipal sewage network, or surface water or river water can be reused through further treatment processes.

Method Features:

Wastewater discharge is generally divided into two parts: domestic wastewater and wastewater generated from related beds. Considering the requirements for water quality and flow rate of incoming and outgoing water, the wastewater treatment process of the Disease Prevention and Control Center must ensure that the treated effluent meets the standards. The three methods used can effectively keep the E. coli count at a low level over a long period, and the effluent from the filtration system can ensure compliance with water quality requirements, with all indicators meeting the national wastewater discharge standards.

Performance Features:

1) The disinfectant produced has a high purity, with a chlorine dioxide content exceeding 98%.

2) High conversion rate, raw material conversion rate of 95%.

3) Advanced imported metering pump control for chemical dosing, with a back pressure valve to prevent siphonage.

4) Simple design structure, easy installation and maintenance.

5) Low or no land occupation.

6) By adjusting the flow meter and dosing pump, various concentrations of chlorine dioxide disinfectant can be produced, particularly suitable for food processing companies, as each process has different requirements for chlorine dioxide disinfectant.

Inspection Laboratory Wastewater Treatment Equipment - Stable Operation - Quankun Material Corrosion-Resistant and Durable

Process Description:

Wastewater from some tanks is pumped into neutralization reactors, adjusting the pH to 69. Heavy metal ions react with alkali to produce hydrogen gas. Laboratory wastewater flows through pipes into a collection tank network.

2. Chemical precipitation.

3. By adding chelating agents to the chelation reaction tank, the chelates formed by the reaction of heavy metals with the chelating agents can further remove heavy metal ions.

4. Then add PAC, PAM sludge, and flocculant.

5. After condensation, the waste water enters a security filter to remove suspended solids.

6. Water production enters the membrane for treatment.

7. Sludge and solid waste must be handled by qualified units. The odor produced by the integrated unit pool must be introduced into the laboratory for waste gas treatment and discharged through pipelines.

8. Install one or more laboratory wastewater treatment systems in the lab space, to highly treat the laboratory wastewater, and then discharge it into the biochemical pond or municipal sewage system after meeting relevant standards.



Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $34000.00 / Tai
Sales None
Delivery JiangsuNanjingPre-sale, after payment7dayswithin
Stock 100TaiMOQ1Tai
Brand Quan Kun
Processing Volume 1-10 T/D
Material Sheet metal/Stainless steel
Voltage 220V/50Hz
Expiry Long Valid
Update 2025-11-04 16:17
Gallery

Jiangsu Quankun Environmental Protection Technology Co., Ltd.Published byInspection Laboratory Wastewater Treatment Equipment - Stable Operation - Quankun Material Corrosion-Resistant and DurableGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top