Suitable for measuring the soil pressure on the shield machine's liner and grouting pressure behind the wall
Even with surface wear under pressure, there is no effect on output and initial value.
Load Cell Type Soil Pressure Gauge, unaffected by bending
Particulate dust pressure for particle diameter φ10 or so
本质-safe explosion-proof construction
This sensor is unaffected by component bending in design and is a load cell-type soil pressure gauge, suitable for measuring wall soil pressure. Available in 12 and 18 models, it can be selected for use based on the installation direction.
Do not apply a load (pressure and weight) exceeding the rated capacity to the loaded surface for proper use. (Refer to the table.)
Specification
| Model Name | Rated Capacity | Load Capacity (Rated Capacity) |
| BER-A-100KP12S | 100kPa | 419N |
| BER-A-200KP12S | 200kPa | 837N |
| BER-A-500KP12S | 500kPa | 2.1kN |
| BER-A-1MP12S | 1MPa | 4.2kN |
| BER-A-2MP12S | 2MPa | 8.4kN |
| BER-A-5MP12S | 5MPa | 20.9KN |
| BER-A-500KP58S | 500kPa | 2.1KN |
| BER-A-1MP58S | 1MPa | 4.2KN |
| BER-A-2MP58S | 2MPa | 8.4KN |
| BER-A-5MP58S | 5MPa | 20.9KN |
Performance
| Rated Capacity | Reference Table |
| Nonlinear | ±1% RO within |
| Lag | ±1% RO within |
| Rated Output | 1mV/V (over 2000×10^-6 strain) |
Environmental Characteristics
| Permitted temperature range | -30~80℃ |
| Temperature Compensation Range | 0~70℃ |
| Zero-point temperature effect | ±0.1% RO/°C within |
| Output Temperature Affects | ±0.1% per °C |
Electrical Characteristics
| High incentive voltage | 10V AC or DC |
| Recommended激励voltage | 2~5V AC or DC |
| Input Resistance | 350Ω±2% |
| Output Resistance | 350Ω±2% |
| Cable | 0.5mm2, 4-core shielded chloroprene armored cable, 30m length, outer diameter 10mm, exposed wire at the front |
| The shielded wire is not connected to the host. |
Mechanical Properties
| Safe Overload | 120% |
| Maximum Load Capacity | Refer to the table |
| Oiled face diameter | Approx. φ73 |
| Outer packaging | Pressure face, stainless steel material |
| Rim, Cable Lead-out Section MF Zn-C Plating | |
| Water resistance of cable termination section | 600kPa |
| Weight | Approx. 3.2 kg (12), approx. 3.1 kg (58) |
※ Optional antibacterial adhesive coating available.
Use Cases

Outline dimension drawing

BER-A-12S

BER-S-18S