Network Line Interference Device, XG-001 Model, 4-Channel Ethernet Line Interference Device


For office buildings that do not meet the standards, when installing line interference devices, there is no need to break walls or slots, causing no damage to the interior and exterior decorations, and it will not affect the use of PCs. There is no need to move office equipment. Simply connect the network card output of the PC to the electrical port of the interference device, and the other electrical port of the interference device is connected with the original RJ-45 connector, and the installation is complete.
Installation and Configuration Method for Line Conduction Interference: The line conduction interference should be installed according to the illustrated method, simple and convenient.
Test Conclusion
The electromagnetic jamming signal emitted by the tested jammer can overpower the leakage information on unshielded twisted pair cables within the IMHz to IGHz frequency band.
② The electromagnetic interference signal emitted by the tested jammer does not affect the normal transmission of data during both low-speed and high-speed data transmission over the network.
No defects.
Our company has conducted tests on the transmission of image files and data files, as well as potential error codes that may arise during the operation of line interference suppressors, using various testing technologies. The results are as follows:
Low error rate: tested for 4 billion bits, no errors detected.
② High-speed: Measures 8 billion bits error-free.
Frequency Range
Interference transmission frequency ranges from IMHz to IGHz, effectively protecting confidential information. Green and environmentally friendly.
Utilizing unique conduction interference technology, interference signals are only transmitted within the network cable, with only trace amounts of electromagnetic radiation emitted into space, thus posing no harm to the human body.
Low interference power
Utilizing unique shielding technology, it is possible to cover up the leaked signals on the network cable without the need for high-power interference sources.
Easy installation and use
Standard case design for easy installation, clean interfaces, and user-friendliness.
Technical Specifications
|
.Interference Frequency: IMHz - IGHz
.Interference Strength: > 3dB above normal transmission signal
Operating Temperature: 10°C to 35°C
Operating Humidity: HR < 75%
AC Working Voltage: 220V ±5%
Continuous Operating Time > 20,000 hours