Supply Electric Stop Valves J941H-16C DN300 Electric High-Temperature Steam Stop Valves Direct from Manufacturer
Product Features
Product advantage
Performance Parameters Table:
Parameter Name Model | Nominal Torque N·m | Torque Control N.m | Torque Control N.m | Allow through valve rod diameter | Manual Speed Ratio | Output Speed: rpm | Motor Power: kW | Weight: Kg |
DZW5 | 50 | 75 | ≤25 |
28 |
1:1 |
18 | 0.12 | |
DZW10 | 100 | 150 | ≤50 | 0.18 | ||||
DZW15 | 150 | 225 | ≤75 | 0.25 | ||||
DZW20 | 200 | 300 | ≤100 | 40 | 0.37 | |||
DZW20I | 28 | |||||||
DZW30 | 300 | 450 | ≤150 | 40 | 0.55 | |||
DZW30I | 28 | |||||||
DZW45 | 450 | 675 | ≤225 |
48 | 24 | 1.1 | 100 | |
36 | 1.5 | |||||||
DZW60 | 600 | 900 | ≤300 | 24 | 1.5 | 103 | ||
36 | 2.2 | |||||||
DZW90 | 900 | 1350 | ≤450 | 60 | 24 | 2.2 | 128 | |
DZW90I | 48 | 36 | 3.0 | |||||
DZW120 | 1200 | 1800 | ≤600 | 60 | 24 | 3.0 | 132 | |
DZW120I | 48 | |||||||
DZW180 | 2500 | 3000 | ≤1250 |
70 |
25:1 | 24 | 4.0 | 245 |
36 | 5.5 | |||||||
DZW250 | 2500 | 3000 | ≤1250 | 24 | 5.5 | 250 | ||
DZW350 | 3500 | 4200 | ≤1750 | 75 | 13:1 | 18 | 7.5 | 450 |
DZW500 | 5000 | 6000 | ≤2500 | 10 | 460 |
Section 2: Technical Specifications
Z: Integrated Type T: Adjustable Type N: Smart Type
Protection Type: W = Outdoor, B = Explosion Proof
Output Speed: Numerical value, unit r/min (revolutions per minute)
Connection Type: T for Thrust Type, I for Power Station Type, Standard Type with No Code; Rated Torque: Number indicates, unit kgf.m
Product Form: Multi-Rotary Electric Device
Power Supply: Motor is 3-phase AC 380V, 50Hz. Control is 2-phase AC 220V, 50Hz.
Optional Power Source: AC 220~660V, 50/60Hz (specify at time of order) 2: Environmental Temperature; -20℃ to +60℃; Optional -40℃ to +70℃
Relative Humidity: Not more than 95% (at 25℃)
4: Working Environment; Standard type for areas without flammable, explosive, and highly corrosive media; Explosion-proof type (ExdIIBT4) applicable to II A, II B groups T1-T4 explosion-proof gases.
The motor is designed for intermittent duty; rated operating time is 10 minutes. F-grade insulation.
7: Corrosion-Resistant Coating: High-Temperature Painting

Product Featuresfeatures

Three: Adjust
Adjust the torque during travel; ensure the potentiometer on the position indicator is disengaged (loosen the set screw on the gear of the potentiometer shaft to disengage) to prevent damage.
Torque control mechanism adjustment:
Firstly, adjust the closing torque.
(2) Begin with a low torque value and gradually increase it until the valve is fully closed.
(3) Adjust the torque of the switch direction according to the valve's operating characteristics; typically, the opening torque is greater than the closing torque.
(4) Adjustments above are made under conditions of no load, no medium pressure, etc. When there is pressure and temperature, pay attention to whether it can be tightly closed. If it cannot be closed tightly, you should appropriately increase the torque value to ensure it can be tightly closed and easily opened.
2. Traveler Control Mechanism Adjustment
(1) Close the valve manually.
(2) Disengage the stroke control mechanism by using a screwdriver to push the top rod in the stroke control mechanism and rotate it 90°, thereby separating the driven small gear from the counter's unit gear set.
(3) Rotate the "Off" position screwdriver towards the adjustment shaft, turning until the cam presses against the spring plate, causing the microswitch to activate. This indicates the initial adjustment of the "Off" position is complete.
(4)
At this point, you can electrically turn it a few rotations, then shut it off. Check if the closing stroke meets the requirements; if not, adjust it again following the aforementioned procedure.
(5) Direction Adjustment: After the valve is adjusted in the closed direction, manually open the valve to the desired position. Then disengage the stroke control mechanism, rotate the "open" adjustment shaft in the direction of the arrow until the cam presses against the spring plate, causing the microswitch to activate. Reengage the stroke mechanism with the driving gear, and the opening stroke is complete. After adjusting the stroke control mechanism, the operation can be repeated several times. Generally, the valve is opened to about 90%.
3. Adjustable opening indicator adjustment:
(1) Adjust the adjustable opening indicator and remote potentiometer after adjusting the torque and stroke.
Product detail imagedetails

Soo Valve brand electric device

Acid and alkali-resistant electric equipment

DZW60 Electric Unit
Company Strengthenterprise
Yangzhou Su Valve Control Equipment Co., Ltd. is located in the historically and culturally renowned city of Yangzhou, China, and is a professional manufacturer specializing in the research, development, and marketing of electric valve actuators. The company has established a reliable quality assurance system, ensuring that product quality standards are strictly implemented. Our product range of electric valve actuators is comprehensive and widely used in power, metallurgy, petroleum, chemical, papermaking, and water supply and drainage industries, earning high praise from customers. For many years, Yangzhou Su Valve Control Equipment Co., Ltd. has adhered to the business philosophy of "Quality, Integrity, and Customer First," gaining recognition from users across various industries, building the company's brand image, and creating high-quality products in the electric valve industry. Our products are based in China and aimed at the global market, serving over 30 provinces, municipalities, and autonomous regions across the country. The company offers comprehensive customer services...
After-Sales Policyafter sale
About Shipment
Subject to customer's requirements
About Returns and Exchanges
If there are any disputes upon receiving the product, please contact us promptly for negotiation and resolution.
Subject to customer's requirements