Supply Electric Stop Valve J941H-16C DN250 Electric High-Temperature Steam Stop Valve Direct from Manufacturer
Product Features
Product advantage
Performance Parameters Table:
Parameter Name Model | Nominal Torque N·m | Torque Control N.m | Torque Control: N.m | Allow through valve rod diameter | Manual speed ratio | Output Speed: r/min | Motor Power: kW | Weight: Kg |
DZW5 | 50 | 75 | ≤25 |
28 |
1:1 |
18 | 0.12 | |
DZW10 | 100 | 150 | ≤50 | 0.18 | ||||
DZW15 | 150 | 225 | ≤75 | 0.25 | ||||
DZW20 | 200 | 300 | ≤100 | 40 | 0.37 | |||
DZW20I | 28 | |||||||
DZW30 | 300 | 450 | ≤150 | 40 | 0.55 | |||
DZW30I | 28 | |||||||
DZW45 | 450 | 675 | ≤225 |
48 | 24 | 1.1 | 100 | |
36 | 1.5 | |||||||
DZW60 | 600 | 900 | ≤300 | 24 | 1.5 | 103 | ||
36 | 2.2 | |||||||
DZW90 | 900 | 1350 | ≤450 | 60 | 24 | 2.2 | 128 | |
DZW90I | 48 | 36 | 3.0 | |||||
DZW120 | 1200 | 1800 | ≤600 | 60 | 24 | 3.0 | 132 | |
DZW120I | 48 | |||||||
DZW180 | 2500 | 3000 | ≤1250 |
70 |
25:1 | 24 | 4.0 | 245 |
36 | 5.5 | |||||||
DZW250 | 2500 | 3000 | ≤1250 | 24 | 5.5 | 250 | ||
DZW350 | 3500 | 4200 | ≤1750 | 75 | 13:1 | 18 | 7.5 | 450 |
DZW500 | 5000 | 6000 | ≤2500 | 10 | 460 |
Section 2: Technical Conditions
Z: Integrated Type T: Adjustable Type N: Smart Type
Protection Type: W for Outdoor, B for Explosion Proof
Output Speed: Numerical value, unit r/min (revolutions per minute)
Connection Type: T for Thrust Type, I for Power Station Type; Standard Type without Code. Rated Torque: Number indicates, unit kgf.m
Product Form: Multi-Rotary Electric Device
1: Power Supply: Motor is 3-phase AC 380V, 50Hz. Control is 2-phase AC 220V, 50Hz.
Optional Power Supply: AC 220~660V, 50/60Hz (to be specified at time of order) 2: Environmental Temperature; -20℃ to +60℃; Optional: -40℃ to +70℃
Relative humidity: Not more than 95% (at 25°C)
4: Working Environment; Standard type for areas without flammable, explosive, and highly corrosive media; Explosion-proof type (ExdIIBT4) suitable for IIA, IIB groups T1-T4 explosive gases.
5: Protection Rating; IP65/67 (Special Order IP68)
The motor is designed for operation; rated running time is 10 minutes. Class F insulation.
7: Corrosion-Resistant Coating: High-Temperature Bake Paint

Product Featuresfeatures

Three: Adjust
Adjust the torque, while in motion, ensure the potentiometer on the position indicator is disengaged (loosen the set screw on the gear of the potentiometer shaft to disengage) to prevent damage.
Torque control mechanism adjustment:
Firstly, adjust the torque.
(2) Start from a low torque value and gradually increase it until the valve is fully closed.
(3) Adjust the torque of the switch direction based on the valve's operating characteristics; generally, the open direction torque is greater than the close direction torque.
(4) Adjustments are made under no-load, no-medium pressure, and other factors. When pressure and temperature are present, attention should be given to whether it can be tightly sealed. If it cannot be sealed properly, the torque value should be appropriately increased to ensure it can be tightly sealed and easily opened.
2. Traveler control mechanism adjustment:
(1) Close the valve manually.
(2) Disengage the stroke control mechanism by using a screwdriver to push the top rod in the stroke control mechanism and rotate it 90°, thus separating the driving sprocket from the counter's unit gear set.
(3) Rotate the "OFF" position screwdriver towards the adjustment shaft, turning until the cam presses against the spring plate, causing the microswitch to activate. This indicates that the "OFF" stroke is initially adjusted.
(4)
At this point, turn a few circles electrically and then close it. Check if the closing stroke meets the requirements; if not, adjust it again following the aforementioned procedure.
(5) Direction Adjustment: After the closed direction is adjusted, manually open the valve to the desired position. Then disengage the stroke control mechanism, rotate the "open" adjustment shaft in the direction of the arrow until the cam presses against the spring plate, causing the micro-switch to activate. Reengage the stroke mechanism with the driving gear, and the opening stroke is complete. After adjusting the stroke control mechanism, repeat the operation a few times. Generally, the valve is opened to about 90%.
3. Adjustable opening degree indicator adjustment:
Adjust the adjustable opening indicator and remote potentiometer after tuning the gear and travel.
Product detail imagesdetails

Suyue Brand Electric Equipment

Acid and alkali-resistant electric device

DZW60 Electric Unit
Corporate Strengthenterprise
Yangzhou SuFang Control Equipment Co., Ltd. is located in the historically and culturally renowned city of Yangzhou, China. It is a specialized manufacturer that researches, develops, and markets electric valve actuation systems. The company has established a reliable quality assurance system, ensuring that product quality standards are thoroughly implemented. Our range of electric valve actuation systems is comprehensive, widely used in power, metallurgy, petrochemical, papermaking, water supply and drainage industries, and highly praised by customers. For many years, Yangzhou SuFang Control Equipment Co., Ltd. has adhered to the business philosophy of "quality, integrity, and customer-first," gaining recognition from users across various industries, building a corporate brand image, and creating high-quality products in the electric valve sector. Our products are based in China, facing the world, and are distributed to over thirty provinces, municipalities, and autonomous regions across the country. The company offers comprehensive customer service...
After-Sales Policyafter sale
About Shipment
Subject to customer's requirements
About Returns and Exchanges
If there are any disputes upon receiving the product, please contact us promptly for negotiation and resolution.
Subject to customer's requirements