The water quality automatic sampler's sampling bottle can be automatically emptied, cleaned, and allows for long-term unattended operation of the sampler. Suitable for environmental protection departments, wastewater treatment plants, drainage management offices, and more.The company's main discharge port automatically collects, stores in cold storage, and empties water samples.
Sampling Modes: Constant current/constant volume, time-proportional, time-constant volume, externally controlled sampling, and time-based sampling, among others.
Automatic Draining: Achieves automatic draining of pipeline and sampling bottle water samples.
Automatic Cleaning Function: Automatically flushes the sampling pipeline and cleans the sampling bottles to prevent cross-contamination of samples.
Power Failure Protection: Automatic protection during power outages, and automatic restoration to operation upon power return.
Records: with sampling records, access records, power outage records.
External Pump Control: Directly control the external pump to extend the sampling distance.
Digital Temperature Control: Refrigerator with digital temperature control and even heat distribution system for uniform and precise temperature.
Sampling Bottle | Specification:2L x 12 bottles/1L x 25 bottles |
Single Sample Quantity | 10ml~1000ml |
Sample interval | 1min~9999min |
Sample Size Error | ±7% |
Proportional sample size error | ±8% |
Sampling Vertical Height | ≥8m |
Horizontal sampling distance | ≥80m |
Piping system airtightness | ≤-0.085MPa |
Water Sample Storage Temperature | 2℃-6℃(±1.5℃) |
Sample Record | 1,000 units |
Access Record | 200 units |
Mean Time Between Failures (MTBF)MTBF) | ≥1440h/operation |
Communication Interface | RS-232/RS-485,4mA~20mA |
Operating Voltage | AC220V±22V,50Hz±0.5Hz |
Work Environment Temperature | 0℃~50℃ |
Workplace humidity | ≤85%RH |
Average Power | 75W |
Dimensions | 595mm x 566mm x 1230mm (Length x Width x Height) |
Weight | 60kg |

![]()