1、 Aging room function:
Load body: CB-ETC480W-8L series electronic load is used.
2 Monitoring function: Equipped with an external PC, it is used to set aging technology parameters and product aging process, monitor the output voltage/current values of the tested product, and automatically determine the aging quality of the product.
3. Timing function: The aging time can be set to any desired time range, with automatic timing function.
4 Aging quantity: Aging 336PCS.
5 Voltage surge function: ON/OFF can be set for multiple periods of time to surge freely.
6. Automatically save data and generate reports.
7 PC intelligent monitoring and temperature control.
2、 Technical parameters of aging room:
Aging cabinet size: 2100 (L) mm * 1910 (H) mm * 800 (W) mm
Aging quantity:
CB-ETC480W-8L series electronic load modules are used for loading, and the aging cabinet is divided into 7 layers, with 48 PCS per layer, for a total aging quantity of 336 PCS
Aging modes CC and CV are optional.
I/O interface: 336 input white sockets, output 336 channels PCB board+1 DC2.5 terminal+1 DC2.1 terminal+DC4.0+DC1.35. (DC socket can be customized according to customers).
PC monitoring software is used to set and display aging current and product output voltage, and has automatic detection and judgment functions for output voltage. The aging voltage and current are set centrally.
The electronic load module has OCP, OVP, OPP, OTP (load protection function);
Automatic constant temperature heating, digital high-precision temperature sensor measurement, heating temperature range (35-55 degrees), 3-sided sliding tempered glass door.
Satisfy the aging of a single high-power 40W power supply.
The whole machine input is three-phase five wire.
3、 Technical specifications for aging electronic loads
1. Introduction to electronic load CB-ETC336W-8L series:
The main features of the aging electronic load CB-ETC336W-8L are flexible and convenient load switching, unmanned operation, labor-saving, optional multi machine parallel function, solving the needs of high-power multi group aging testing, load current soft start function, stable load performance without any impact on the tested product throughout the load process, modularized main control, simple and convenient operation interface, easy to use and adjust, constant current and voltage (optional) load working mode, main power devices imported from the United States and Japan, long life and high reliability, and stepless digital setting of load current/voltage values; High brightness LED dual screen display sets voltage and current values, intuitive and simple, with high reliability OCP, OVP, OPP, OTP (load protection function), and a fault free interval time (MTBF) of up to 100000 hours.
2. Main technical parameters of electronic load CB-336W-8L:
Function/Model
ETC-336W-8L
Remarks
1
Load working mode
CC, CV (can be connected in parallel with multiple channels)
2
DC input voltage range
0.5V-120V
3
DC input current range
0.02A-5A
4
Load capacity
60W
5
Module large input total power
480W
6
number of channels
8-channel
7
Current display degree
±3%
8
Linearity of current display
±3%
9
Overpower protection
≥ 100 W automatic protection
The LED indicator light is flashing
10
cooling method
air cooling
11
Stepless temperature control energy-saving fan
Automatic shutdown at ≤ 110 ℃
NTC temperature control
12
Load working input power supply voltage
DC-12V
13
control mode
The load module can set parameters for multiple parallel machines
14
Power consumption of the working machine
≤5W
single unit
15
Service life (MTBF)
More than 100000 hours
16
working environment
-10~55℃
17
Overall dimensions
2100(L)mm*1910(H)mm*800(W)mm
18
weight
19
monitor model
PC serial port monitoring
20
software
PC control
undefined