Chinese name: Rubber Waterstop
Main raw materials: natural rubber and various synthetic rubbers
Temperature range: -45 ℃ -+60 ℃
Brand: Henghai Rubber
Suggested retail price: 20
rubber waterstop
Specification Model
200*6 200*8 200*10
250*6 250*8 250*10
280*6 280*8 280*10
300*6 300*8 300*10
350*8 350*10 350*12
400*8 400*10 400*12
450*8 450*10 450*12
500*8 500*10 500*12
24-hour service hotline: 15632866999

The series of rubber waterstops produced by our company are produced according to the national standard GB18173.2-2000, and the appearance quality requirements are all in accordance with the national standard. If the user has special requirements, it can be manufactured according to the user's requirements.
Performance characteristics:
Back mounted rubber waterstopMainly using natural rubber and various synthetic rubbers as the main raw materials, mixed with various additives and fillers,After plastic refining, mixing, and compression molding, there are many varieties and specifications, including bridge type, mountain type, P type, U type, Z type, and B typeT-shaped, H-shaped, E-shaped, Q-shaped, etc. Back mounted rubber waterstop can be classified as medium buried rubber waterstop according to usageAnd back mounted rubber waterstop.
Back mounted rubber waterstop utilizes the high elasticity of rubber to produce elastic deformation under various loads, thereby playing a roleDurable sealing effectively prevents water leakage and seepage in building structures, and provides shock absorption and buffering effects. In many engineering constructionsIn the design, there are certain expansion and contraction requirements between civil engineering and water and soil structures, as well as issues such as waterproofing and earthquake resistance. ThereforeThe adoption and installation of rubber waterstops is an effective means to solve the above problems. This product is mainly used for concreteFoundation engineering and underground facilities that are integrated with concrete structures and installed in construction joints and deformation joints during cast-in-place constructionTunnel culverts, water conveyance aqueducts, water retaining dams, etc. ensure the service life of engineering construction.
Installation and precautions:
1. The concrete interface of the fixed water stop strip should be kept flat and dry. Before installation, remove the floating slag, dust, and debris from the interface. Use steel nails or adhesive to fix the water stop strip at the determined installation location. But the surface with grouting pipes must be placed on the original concrete interface.
2. When the grouting pipe type is connected to the water swelling water stop strip, the parallel overlapping method is used, and no breakpoint is left in between. The water stop strip at the connection is reinforced and fixed with steel nails, and the reserved grouting connection pipe on the water stop strip is inserted into another equal water stop strip and connected to the two-way joint.
3. According to the length of the installed water stop strip, a three-way joint should be installed at a distance of about 30 meters. One end of the straight three-way joint should be inserted into the water stop strip, the other end should be inserted into the grouting connection pipe, and the other T-shaped end should be inserted into the spare grouting to prevent chemical grouting water leakage in case of gaps.
4. The grouting connection pipe in the connected waterstop must be firmly bonded to the three-way connector, and the grouting pipe of the installed waterstop must be ensured to be completely unobstructed. The spare grouting pipe installed on the tee should be placed in the direction of the inner wall.
5. Each box contains a bottle of grouting pipe adhesive (used for connecting the grouting pipe to the two-way and three-way joints on the water stop strip), as well as a spare grouting pipe placed inside the inner wall for connecting the three-way joint