Coal mine flame-retardant control cable_供应产品_Tianjin Cable Corporation's Rubber and Plastic Cable Factory 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Tianjin Cable Corporation's Rubber and Plastic Cable Factory

Coal mine rubber sheathed cables, coal mine optical cables, coal mine control...

Consultation Hotline
13613264222

联系方式
  • Contact person:李文通
  • Telephone:13613264222
  • Mobile:13613264222

Product Categories
Home > 供应产品 > Coal mine flame-retardant control cable
Coal mine flame-retardant control cable
品牌: Yin Shun
Core wire material: Oxygen-Free Copper Wire
Insulating material: Polyvinyl Chloride (PVC)
Sleeve Material: PVC (Polyvinyl Chloride)
单价: 1.00/Rice
最小起订Quantity: 1 Rice
供货总Quantity: 1 Rice
有效期至: 长期有效
最后更新: 2024-11-04 15:21
 
详细Info

Coal mine flame-retardant control cable

MKVVCoal mine control cablesMKVVPPlastic control cables for coal minesMKVV22Plastic insulated cables for coal mines

Standard of Execution: Company StandardQ/TX001-2006 This standard applies to flame-retardant control cables with copper-core polyvinyl chloride sheath for use in coal mines.

Cable model, name, specifications, and application

MKVV Copper-core Polyethylene Insulated PVC Sheathed Flame-retardant Mining Control Cable (2-14)*(4-6)(2-61)*(0.75-2.5) for fixed installations indoors, cable trays, pipelines, etc. MKVV22 Copper-core Polyethylene Insulated PVC Sheathed Steel Tape Armored Flame-retardant Mining Control Cable (7-61)*(0.75-1.5)(4-14)*(4-6) for fixed installations indoors, cable trays, pipelines, direct burial, capable of withstanding significant mechanical forces. MKVV32 Copper-core Polyethylene Insulated PVC Sheathed Wire Armored Flame-retardant Mining Control Cable (2-61)*(0.75-2.5)(4-14)*(4-6) for fixed installations indoors, cable trays, pipelines, direct burial, hanging, capable of withstanding significant tensile forces. MKVVP22 Mining Use Copper-core Polyethylene Insulated PVC Sheathed Braided Shielded Steel Tape Armored Flame-retardant Control Cable (4-14)*(4-6)(4-61)*2.5mm2 for fixed installations in high-magnetic field indoors, cable trays, pipelines, direct burial, hanging, capable of withstanding significant tensile forces. MKVVRP Mining Use Copper-core Polyethylene Insulated PVC Sheathed Braided Shielded Flame-retardant Control Flexible Cable (4-61)*(0.5-2.5)(4-37)*(1.5-2.5) for fixed installations in high-magnetic field indoors, cable trays, pipelines, etc.

MKVVCable,MKVVPCable,MKVVP2Cable,MKVV22Cable,MKVV32Cable,MKVVRCable,MKVVRPCable,MKVVP22Flame-retardant control cables for coal mines, etc., with specifications and models, recommend a cable core number of2,3,4,5,7,8,10,12,14,16,19,24,27,30,37,44,48,52,61Chip

 

MKVV(2-14)*(4-6)mm2 ,(2-10)*10mm2 (2-61)*(0.75-2.5)mm2 MKVV22(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2 MKVVP(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2 MKVVP22(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2

1Rated Voltage450/750v

2The length of the cable conductor is permitted for operation at temperatures of70Celsius

3The laying temperature of the cables should not be lower than0Celsius, recommended allowable bend radius;

4Unarmored cables should not be less than the outer diameter of the cable.6X2

5Cables with armored or copper braid shielding should be no less than the cable's outer diameter.12Multiple.

6Flexible cables with shielding structures should not be less than the outer diameter of the cable.6Multiple.

MT386-1995"Test Methods and Evaluation Rules for Flame Retardant Cables Used in Coal Mines"Q/TX 001-2006 Plastic Insulated Control Cable for Coal Mines


询价单
 Click submit means you agree to《Service terms》《Privacy policy》

13613264222